Infrared Spectral Characteristics and Mixing Ratio Detection Method of a New Environmentally Friendly Insulating Gas C5-PFK

SPECTROSCOPY AND SPECTRAL ANALYSIS(2023)

引用 0|浏览1
暂无评分
摘要
1,1,1,3,4,4,4-heptafluoro-3-(trifluoromethyD-2-butanone (C5-PFK) gas has attracted widespread attention at home and abroad due to its excellent electrical insulation properties and good environmental protection properties. Preparing high-precision C5-PFK mixed gas and accurately detecting the mixing ratio is conducive to the scientific demonstration of C5-PFK mixed gas and minimizes potential power hazards. The FTIR experiment, combined with the B3LYP method for spectral theoretical calculation, was used to study the infrared spectral absorption characteristics of C5-PFK gas. For CO2 and micro water gas that may exist in the test environment, the cross-interference analysis of spectral lines was carried out under the same conditions as temperature, pressure and optical path; The C5-PFK gas mixture ratio sensor was simulated and tested based on NDIR technology, and the overall design of the sensor hardware system was carried out. According to the output characteristics of the sensor, a BP neural network temperature compensation model is established, and the repeatability and indication error of the sensor are tested. The results show that the strong absorption peak positions of C5-PFK gas are 1 200, 1 262 and 1 796 cm i, respectively, and the molecular theoretical calculation agrees with the gas's measured infrared spectrum. Under the background of synthetic air, the absorbance of CO2 gas at 1 262 cm i position is 6. 04X 10(-7), the influence factor of micro water peak area in 150 nm filter bandwidth is about 3.15 X 10(-3) s, and the cross-interference of spectral lines can be ignored. It is feasible to realize mixing ratio detection at a 1 262 cm(-1) position. The range tracks the optical path, and the sensor simulation test results show that the 6. 5 mm optical path can realize the detection of the C5-PFK mixture ratio of 0 similar to 15%. The output characteristics of the sensor show that the value of the absorption variable SA/SB decreases with the increase in temperature, showing a nonlinear relationship. The maximum indication error of 10% C5-PFK/Air mixture before and after temperature compensation by the BP neural network algorithm is 29.23% and 1.29%, respectively, and the output absorption variable SA/SB value remains unchanged after compensation. The sensor repeatability test shows that the RSD is O. 27%, less than 3 Yo. The linear fitting coefficient R-2 of the sensor indication corresponding to different concentrations is 0. 999, and the maximum indication error is 2. 47%. In summary, the advantages of the detection method and its sensor in the detection range of C5-PFK gas mixture ratio, anti-interference ability and reliability are verified, and a feasible solution for detecting the mixture ratio of C5-PFK gas mixture electrical equipment is provided.
更多
查看译文
关键词
1,1,1,3,4,4 4-heptafluoro-3-( trifluoromethyl)-2-butanone,Infrared spectral characteristics,NDIR technology,Dual wavelength infrared difference,Simulation test,Sensor output characteristic,Temperature compensation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要