Identification and treatment of persistent small airway dysfunction in paediatric patients with asthma: a retrospective cohort study

Lulu Zhang,Zhou Fu, Hua Deng, Qin Xie,Wenjie Wu

BMC Pulmonary Medicine(2024)

引用 0|浏览6
暂无评分
摘要
Background Asthma is a common respiratory disease. In asthma, the small airways have more intensive inflammation and prominent airway remodelling, compared to the central airways. We aimed to investigate the predictive value of risk factors and the fractional concentration of exhaled nitric oxide (FeNO) for persistent small airway dysfunction (p-SAD), and compare the effects of different treatment modalities. Methods This retrospective cohort study included 248 children with asthma (aged 4–11 years). Binary logistic regression was used to analyse the risk factors for p-SAD. Correlations among FEV 1 /FVC, small airway function parameters, and FeNO levels in patients with asthma were analysed using Spearman’s rank correlation. The receiver operating characteristic curve and the Delong test were used to analyse the predictive value of FeNO for p-SAD. Differences in the treatment effects of inhaled corticosteroids (ICS) and ICS with a long-acting beta-agonist (ICS/LABA) on p-SAD were analysed using Fisher’s exact test. Results Asthmatic children with older age of receiving the regular treatment (OR 1.782, 95% CI 1.082–2.935), with younger age at the time of onset of suspected asthma symptoms (OR 0.602, 95% CI 0.365–0.993), with longer duration of using ICS or ICS/LABA (OR 1.642, 95% CI 1.170–2.305) and with worse asthma control (OR 3.893, 95% CI 1.699–8.922) had increased risk for p-SAD. Significant negative correlations of small airway function parameters with FeNO at a 200 mL/s flow rate (FeNO 200 ), and the concentration of nitric oxide in the alveolar or acinar region (CaNO) were observed. The areas under the curve of FeNO 200 (cut-off:10.5ppb), CaNO (cut-off:5.1ppb), and FeNO 200 combined with CaNO were 0.743, 0.697, and 0.750, respectively, for asthma with p-SAD. After using ICS or ICS/LABA, switching to ICS/LABA was easier than continuing with ICS to improve small airway dysfunction (SAD) in the 8th month. Conclusions Paediatric asthma with p-SAD is associated with older age at receiving regular treatment, younger age at the time of onset of suspected asthma symptoms, longer duration of using ICS or ICS/LABA, worse asthma control, and higher FeNO 200 and CaNO levels, all of which can be combined with small airway function indicators to distinguish p-SAD from asthma. ICS/LABA improves SAD better than ICS alone.
更多
查看译文
关键词
Paediatric asthma,Persistent small airway dysfunction,Identification,Treatment,Risk factors
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要