The effectiveness of adjustable trans-obturator male system (ATOMS) in radiated patients is reduced: A propensity score-matched analysis

Javier C. Angulo,Alessandro Giammo,Fabian Queissert, Sandra Schoenburg, Carmen Gonzalez-Enguita,Andreas Gonsior, Antonio Romero,Francisco E. Martins,Tiago Antunes-Lopes, Raquel Gonzalez,Juliusz Szczesniewski,Carlos Tellez,Francisco Cruz,Keith F. Rourke

BJUI COMPASS(2024)

引用 0|浏览0
暂无评分
摘要
Objectives: This study aimed to compare the effectiveness and safety of the adjustable trans-obturator male system (ATOMS (R)) to treat post-prostatectomy incontinence (PPI) in radiated patients compared with non-radiated patients, using propensity score-matching analysis to enhance the validity of the comparison. Patients and methods: Consecutive men with PPI treated with silicone-covered scrotal port ATOMS (A.M.I., Feldkirch, Austria) in nine different institutions between 2016 and 2022 were included. Preoperative assessment evaluated 24-h pad usage, urethroscopy and urodynamics, if indicated. Propensity score-matching analysis was based on age, length of follow-up, previous PPI treatment, previous bladder neck stricture, androgen deprivation and pad usage. The primary endpoint was dry rate, defined as no pads post-operatively with a security pad allowed. The secondary endpoints were complications, device removal and self-perceived satisfaction with the Patient Global Impression of Improvement (PGI-I) scale. Results: Of the 710 included patients, 342 were matched, and the study groups were balanced for the baseline matched variables. The mean baseline 24-h pad was 4.8 in both groups (p = 0.48). The mean follow-up was 27.5 +/- 18.6 months, which was also equivalent between groups (p = 0.36). The primary outcome was achieved in 73 (42.7%) radiated patients and in 115 (67.3%) non-radiated patients (p < 0.0001). The mean pad count at the last follow-up was 1.5 and 0.8, respectively (p < 0.0001). There was no significant difference in complications (p = 0.94), but surgical revision and device explant rates were higher (p = 0.03 and p = 0.01, respectively), and the proportion of patients highly satisfied (PGI-I = 1) was lower in the radiated group (p = 0.01). At sensitivity analysis, the study was found to be reasonably robust to hidden bias. Conclusion: ATOMS implantation significantly outperformed in patients without adjuvant radiation over radiated patients.
更多
查看译文
关键词
adjustable trans-obturator male system,complications,outcomes,post-prostatectomy incontinence,radiotherapy,satisfaction
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要