谷歌浏览器插件
订阅小程序
在清言上使用

Ambient Vibration Analysis of Diversion Pipeline in Mount Changlong Pumped-Storage Power Station

Jijian Lian, Linrui Zuo,Xiaoqun Wang, Lu Yu

APPLIED SCIENCES-BASEL(2024)

引用 0|浏览8
暂无评分
摘要
This study analyzes the ambient vibrations induced while running the Mount Changlong pumped-storage power station (PSPS). The ground vibration data of the power station during its operation were acquired with vibration sensors. Different units were selected and compared under working conditions, and the conclusions were as follows: (1) Ambient vibrations induced by the running of units constituted the primary source of vibration, and they attenuated as the distance increased. (2) The vibration acceleration under pumping conditions was larger than that under power generation conditions, and the ground vibration acceleration increased with an augmentation of the power. (3) The running of adjacent units generated mutual interference, and the types of units were different, which led to complex variations in the spectrum maps. (4) The vibration acceleration of the lower flat tunnel was prone to surpassing the standard when the number of units running together exceeded three.
更多
查看译文
关键词
pumped-storage power station,ambient monitoring,diversion pipeline,analysis of vibration,vibration standard