Experimental study on axial compression fatigue of grouted connection in jacket offshore wind turbines

Engineering Structures(2024)

引用 0|浏览0
暂无评分
摘要
The grouted connection (GC) of the offshore wind turbine (OWT) jacket foundation mainly bears axial loads, the wind and wave load in the working environment make the structure prone to fatigue problems. The construction environment of the OWT foundation is relatively harsh, so there will be vertical and horizontal errors during the construction process. In this paper, the fatigue test of 9 specimens were designed to analyze the influence of vertical and horizontal errors, water ingression and other factors on the axial fatigue performance of the GC section. The static ultimate bearing capacity test was carried out to determine the load ranges of the fatigue test. Results of fatigue tests indicate that the fatigue performance of the GC considerably degenerates with the load eccentricity, especially at the end sections of the inner and outer tubes. Water ingression has a significant negative influence on the fatigue performance of the GC section. The presence of water contributes to the propagation and development of cracks in the grout layer. Load range, vertical and horizontal errors and grout material have negligible effect on the fatigue performance of the structure.
更多
查看译文
关键词
Grouted connection,Fatigue test,Axial loading,Construction error