Chrome Extension
WeChat Mini Program
Use on ChatGLM

Evaluation of an Automated Von Willebrand Factor GPIbM Activity Assay Compared to Three Alternative Von Willebrand Factor Activity Assays.

Kenneth D. Friedman, Martina Boehm-Weigert, Nicole Desimone,Dennis J. Dietzen,Charles Eby, Cynthia Flickinger, Walter Hoyer, Mareike Kahl,Kandice Kottke-Marchant,Thomas L. Ortel,Juergen Patzke,Steven W. Pipe, Morgan Stuart,Ayse Anil Timur,Ravindra Sarode

Research and practice in thrombosis and haemostasis(2024)

Cited 0|Views10
No score
Abstract
Background: To overcome deficiencies of the traditional von Willebrand factor (VWF) ristocetin cofactor activity assay (VWF:RCo), several automated assays for VWF platelet-binding activity have been developed. Information on the performance of these assays and their diagnostic utility remains limited. Objectives: To validate the VWF:glycoprotein IbM assay INNOVANCE VWF Ac and compare it with an automated VWF:RCo assay as well as with an automated assay and a manual VWF:Ab assay and to generate reference ranges and analyze reproducibility of the VWF:glycoprotein IbM assay. Methods: Clinical sites enrolled healthy subjects and patients representing the intended use population; VWF activity assays were performed, and results were analyzed. The performance of the INNOVANCE VWF Ac assay was also compared between the BCS XP System and the CS-2500 and CS-5100 analyzers. Results: The INNOVANCE VWF Ac assay correlated well with the VWF:RCo assay and the automated HemosIL VWF:Ab assay, with Pearson coefficients of >.9 and a predicted bias of <= 5.0 IU/dL at VWF levels of 30 IU/dL and <= 5.8 IU/dL at the levels of 50 IU/dL, but correlation and bias were not as good when compared with the REAADS manual VWF:Ab assay. Reference ranges observed for healthy subjects correlated well with previously published findings. Reproducibility of the INNOVANCE VWF Ac assay on the BCS XP System and the CS analyzers was excellent, as was correlation among devices. Conclusion: The characteristics of the INNOVANCE VWF Ac assay regarding comparability with other VWF activity assays, reference ranges, and precision support the use of this assay for evaluation of patients with concern for von Willebrand disease.
More
Translated text
Key words
diagnosis,reference range,reproducibility of results,,ristocetin cofactor,von Willebrand disease,von Willebrand factor
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined