Background and Objective: While optical coherence tomography (OCT) is explored as a potential biomarker in Parkinson’s disease (PD), technetium-99m-labeled tropane derivative (99mTc-TRODAT-1) single-photon emission computed tomography (SPECT) imaging has a proven role in diagnosing PD. Our objective was to compare the OCT parameters in PD patients and healthy controls (HCs) and correlate them with 99mTc-TRODAT-1 parameters in PD patients. Materials and Methods: This cross-sectional study included 30 PD patients and 30 age- and gender-matched HCs. Demographic data, PD details including Movement Disorders Society Unified Parkinson’s Disease Rating Scale-III (MDS-UPDRS-III) and Hoehn–Yahr (HY) staging, and OCT parameters including macular and peripapillary retinal nerve fiber layer (RNFL) thickness in bilateral eyes were recorded. PD patients underwent 99mTc-TRODAT-1 SPECT imaging. The terms “ipsilateral” and “contralateral” were used with reference to more severely affected body side in PD patients and compared with corresponding sides in HCs. Results: PD patients showed significant ipsilateral superior parafoveal quadrant (mean ± standard deviation [SD] = 311.10 ± 15.90 vs. 297.57 ± 26.55, P = 0.02) and contralateral average perifoveal (mean ± SD = 278.75 ± 18.97 vs. 269.08 ± 16.91, P = 0.04) thinning compared to HCs. Peripapillary RNFL parameters were comparable between PD patients and HCs. MDS-UPDRS-III score and HY stage were inversely correlated to both ipsilateral (Spearman rho = -0.52, P = 0.003; Spearman rho = -0.47, P = 0.008) and contralateral (Spearman rho = -0.53, P = 0.002; Spearman rho = -0.58, P < 0.001) macular volumes, respectively. PD duration was inversely correlated with ipsilateral temporal parafoveal thickness (ρ = -0.41, P = 0.02). No correlation was observed between OCT and 99mTc-TRODAT-1 SPECT parameters in PD patients. Conclusion: Compared to HCs, a significant thinning was observed in the ipsilateral superior parafoveal quadrant and the contralateral average perifoveal region in PD patients. Macular volume and ipsilateral temporal parafoveal thickness were inversely correlated with disease severity and duration, respectively. OCT and 99mTc-TRODAT-1 SPECT parameters failed to correlate in PD patients.
更多
查看译文
关键词
Tc-99m-TRODAT-1 SPECT,optical coherence tomography,Parkinson's disease,retinal nerve fiber layer,striatum
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要