谷歌浏览器插件
订阅小程序
在清言上使用

Ηand Dexterities Assessment in Stroke Patients Based on Augmented Reality and Machine Learning Through a Box and Block Test

Scientific reports(2024)

引用 0|浏览10
暂无评分
摘要
A popular and widely suggested measure for assessing unilateral hand motor skills in stroke patients is the box and block test (BBT). Our study aimed to create an augmented reality enhanced version of the BBT (AR-BBT) and evaluate its correlation to the original BBT for stroke patients. Following G-power analysis, clinical examination, and inclusion-exclusion criteria, 31 stroke patients were included in this study. AR-BBT was developed using the Open Source Computer Vision Library (OpenCV). The MediaPipe's hand tracking library uses a palm and a hand landmark machine learning model to detect and track hands. A computer and a depth camera were employed in the clinical evaluation of AR-BBT following the principles of traditional BBT. A strong correlation was achieved between the number of blocks moved in the BBT and the AR-BBT on the hemiplegic side (Pearson correlation = 0.918) and a positive statistically significant correlation (p = 0.000008). The conventional BBT is currently the preferred assessment method. However, our approach offers an advantage, as it suggests that an AR-BBT solution could remotely monitor the assessment of a home-based rehabilitation program and provide additional hand kinematic information for hand dexterities in AR environment conditions. Furthermore, it employs minimal hardware equipment.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要