Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care.

M Atif Yaqub, Marta Zanoletti,Lorenzo Cortese, Daniel Senciales Sánchez, Caterina Amendola,Lorenzo Frabasile, Umut Karadeniz, Jacqueline Martinez Garcia, Marta Martin, Jordi Cortes-Picas, Alba Caballer, Edgar Cortes, Sara Nogales,Alberto Tosi, Talyta Carteano, Diego Sanoja Garcia, Jakub Tomanik, Tessa Wagenaar, Hsiao Mui, Claudia Nunzia Guadagno, Shahrzad Parsa, Sanathana Konugolu Venkata Sekar, Luc Demarteau, Tijl Houtbeckers,Udo M Weigel, Michele Lacerenza,Mauro Buttafava, Alessandro Torricelli,Davide Contini, Jaume Mesquida,Turgut Durduran

Journal of visualized experiments : JoVE(2024)

引用 0|浏览0
暂无评分
摘要
The detection of levels of impairment in microvascular oxygen consumption and reactive hyperemia is vital in critical care. However, there are no practical means for a robust and quantitative evaluation. This paper describes a protocol to evaluate these impairments using a hybrid near-infrared diffuse optical device. The device contains modules for near-infrared time-resolved and diffuse correlation spectroscopies and pulse-oximetry. These modules allow the non-invasive, continuous, and real-time measurement of the absolute, microvascular blood/tissue oxygen saturation (StO2) and the blood flow index (BFI) along with the peripheral arterial oxygen saturation (SpO2). This device uses an integrated, computer-controlled tourniquet system to execute a standardized protocol with optical data acquisition from the brachioradialis muscle. The standardized vascular occlusion test (VOT) takes care of the variations in the occlusion duration and pressure reported in the literature, while the automation minimizes inter-operator differences. The protocol we describe focuses on a 3-min occlusion period but the details described in this paper can readily be adapted to other durations and cuff pressures, as well as other muscles. The inclusion of an extended baseline and post-occlusion recovery period measurement allows the quantification of the baseline values for all the parameters and the blood/tissue deoxygenation rate that corresponds to the metabolic rate of oxygen consumption. Once the cuff is released, we characterize the tissue reoxygenation rate, magnitude, and duration of the hyperemic response in BFI and StO2. These latter parameters correspond to the quantification of the reactive hyperemia, which provides information about the endothelial function. Furthermore, the above-mentioned measurements of the absolute concentration of oxygenated and deoxygenated hemoglobin, BFI, the derived metabolic rate of oxygen consumption, StO2, and SpO2 provide a yet-to-be-explored rich data set that can exhibit disease severity, personalized therapeutics, and management interventions.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要