谷歌浏览器插件
订阅小程序
在清言上使用

Abstract P457: Sociodemographic Differences in Cardiac Device Implantation in the Atherosclerosis Risk in Communities (ARIC) Study

Circulation(2024)

引用 0|浏览7
暂无评分
摘要
Introduction: Progression of cardiac arrhythmia or heart failure often leads to treatment with a cardiovascular implantable electronic device (CIED) such as a pacemaker or pacemaker combined with an implantable cardioverter-defibrillator (ICD). Although small, hospital-based studies suggest that CIED implantation differs by sociodemographic factors, few community-based, cohort studies have prospectively evaluated it by sex, race, age, or health insurance status. Methods: We therefore examined incident CIED implantation in the Atherosclerosis Risk in Communities study (ARIC) among 15,527 eligible participants from four U.S. communities (mean age 54.2 years; 55% female; 27% Black; 90% insured) who self-identified as either Black or white and had a resting, standard twelve-lead electrocardiogram (ECG), but no ECG evidence of a pacemaker or ICD at baseline. We identified incident CIED implantation, defined as the initial device placement per participant, using International Classification of Disease (ICD)-9, ICD-10, and Current Procedural Terminology (CPT) codes during follow-up, right-censored at the time of CIED implantation, death, or end of cohort surveillance (December 31, 2020), whichever came first. We computed follow-up times and person-time denominators, then estimated the corresponding incident implantation rates overall, by sociodemographic factors, and device type. Results: Over a mean [standard deviation] follow-up of 24.0 [9.0] years, we identified 1,068 incident CIED (75% pacemaker; 25% ICD) implantations. Incident CIED implantation rates were higher among male, white, older, and insured participants (38, 30, 38, and 29 per 10,000 person-years) than among female, Black, younger, and uninsured participants (21, 23, 20, and 21 per 10,000 person-years). Relative to their counterparts, CIED incidence rates were lower among female, Black, younger, and uninsured participants: incidence rate ratio (95% confidence interval) = 0.55 (0.49-0.62), 0.77 (0.66-0.89), 0.53 (0.47-0.60), and 0.72 (0.56-0.92), respectively. When analyzed separately, patterns of incident implantation were similar for both pacemakers and ICDs. Conclusion: The sociodemographic patterning of incident CIED implantation is manifest and consistent across device type in this U.S. community-based cohort. Although the clinical, behavioral, and sociocultural reasons for the relative infrequency of implantation among female, Black, younger, and uninsured participants remain unclear, ongoing analyses are examining these differences.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要