• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    A

    Arbeitsgemeinschaft Mauerziegel

    企业EST. 1990
    36论文总数
    104引用总数

    论文量&引用量时间轴

    机构学者

    排序
    Udo Meyer
    Udo Meyer
    Arbeitsgemeinschaft Mauerziegel im Bundesverband der Deutschen Ziegelindustrie e. V
    论文:26引用:0H-index:0
    Ekkehard Fehling
    Ekkehard Fehling
    Chair of Structural Concrete, University of Kassel
    论文:7引用:0H-index:0
    Michael Gierga
    Michael Gierga
    Kurz & Fischer GmbH
    论文:5引用:0H-index:0
    Christoph Butenweg
    Christoph Butenweg
    Institute of Structural Statics and Dynamics;RWTH Aachen University
    论文:4引用:0H-index:0
    Detleff Schermer
    Detleff Schermer
    Fakultät Bauingenieurwesen, Ostbayerische Technische Hochschule Regensburg
    论文:4引用:0H-index:0
    Wolfgang Brameshuber
    Wolfgang Brameshuber
    Institute of Building Materials Research (IBAC), RWTH Aachen University
    论文:3引用:0H-index:0
    Andreas Fäcke
    Andreas Fäcke
    Bauwesen GmbH, D-76133 Karlsruhe, Germany
    论文:2引用:0H-index:0
    Christoph Gellert
    Christoph Gellert
    SDA Engn GmbH
    论文:2引用:0H-index:0
    Markus Graubohm
    Markus Graubohm
    Brameshuber + Uebachs INGENIEURE GmbH
    论文:2引用:0H-index:0

    论文(36)

    年份
    起
    –
    止
    排序
    1Acoustic Design Of Multi-Storey Buildings With External Walls Of Monolithic Clay Masonry
    Kai Naumann

    For masonry buildings with monolithic, highly insulated walls of clay units, no acoustic design according to standard was practically possible under Supplement 1 to DIN 4109:1989. Therefore a design procedure regulated by approvals was introduced in 2010, with which acoustic calculations for a building could be performed with a high security of forecasting. This procedure has been taken up in the completely revised series of standards DIN 4109:2016/2018 "Sound insulation in buildings".The basis for the application of this method is knowledge of the individual sound insulation quantities and joint sound insulation quantities for the relevant clay masonry products or product combinations. In order to simplify performance of the verification for clay masonry buildings, the clay masonry industry provides the program "Modul Schall 4.0" (Acoustic module 4.0), in which the decisive acoustic parameters of external wall products from numerous clay masonry unit producers are stored in a database. In this report, experience of application of the design procedure for clay masonry buildings is presented. There is good agreement between forecasts and tests on completed buildings.

    2020MAUERWERK(2020)引用:2
    引用
    AI阅读
    加入学术空间
    2Schubversuche an Geschosshohen Wänden Aus Wärmedämmendem Planziegelmauerwerk Mit Dünnbettmörtel
    Detleff Schermer,Udo Meyer,Marjana Lutman,Petra Triller

    The paper presents results of a series of 6 in-plane shear tests on storey-height clay unit masonry panels [1] with thin-layer mortar, carried out in addition to previous test campaigns [2], [3], and [4]. The walls were constructed with unfilled thermally insulating clay units with a thermal conductivity of lambda = 0.09 W/(m . K). The current design rules for clay unit masonry according to DIN EN 1996-1-1/NA [5] are conservative compared to the presented test results for thermally insulating clay unit masonry.

    2019MAUERWERK(2019)引用:6
    引用
    AI阅读
    加入学术空间
    3Schubtragfähigkeit Von Ziegelmauerwerk Mit Teilweise Aufliegender Deckenplatte
    Thomas Pfetzing,Ekkehard Fehling,Udo Joachim Meyer

    AbstractIn order to investigate the influence of a partially supported slab on the in‐plane shear resistance of masonry walls, six shear tests on full scale walls were performed at the Chair of Structural Concrete of the University of Kassel in cooperation with ”Arbeitsgemeinschaft Mauerziegel“. The walls were made of large chamber clay masonry units and the depths of the partially supported slabs were different. The large chamber units are typically used for thermally insulated exterior walls, with the slabs only being partially supported. The influence of this constellation is not taken into account in shear capacity assessment according to the current version of Eurocode 6 for Germany. This article describes the test results and provides a comparison with Eurocode 6. In addition, the results of older shear tests on masonry walls made of vertically perforated units with eccentric load application were used.

    2019˜Das œMauerwerk(2019)引用:1
    引用
    AI阅读
    加入学术空间
    4Shear Capacity Of Brick Masonry With Partially Supported Slab
    Thomas Pfetzing,Ekkehard Fehling,Udo Joachim Meyer

    In order to investigate the influence of a partially supported slab on the in-plane shear resistance of masonry walls, six shear tests on full scale walls were performed at the Chair of Structural Concrete of the University of Kassel in cooperation with "Arbeitsgemeinschaft Mauerziegel". The walls were made of large chamber clay masonry units and the depths of the partially supported slabs were different. The large chamber units are typically used for thermally insulated exterior walls, with the slabs only being partially supported. The influence of this constellation is not taken into account in shear capacity assessment according to the current version of Eurocode 6 for Germany. This article describes the test results and provides a comparison with Eurocode 6. In addition, the results of older shear tests on masonry walls made of vertically perforated units with eccentric load application were used.

    2019MAUERWERK(2019)
    引用
    AI阅读
    加入学术空间
    5Shear Tests on Thermal Insulating Clay Unit Masonry Walls with Thin Layer Mortar
    Detleff Schermer, Jonathan Schmalz,Udo Meyer,Matija Gams,Marjana Lutman,Petra Triller

    The paper presents the results of 20 shear tests on full scale thermal insulating clay unit masonry walls. The types of units used (units with large chambers filled with mineral wool pads and units with small corings filled with mineral wool granulate) as well as the tested wall geometries and vertical loads are representative of the most common wall constructions currently used in housing in Germany. The aim of the investigations was the verification of the shear -resistance of thermal insulating clay unit masonry under realistic conditions and comparison with the design rules in the codes and national technical approvals. The current design rules for clay unit masonry in DIN EN 1996-1-1/NA are rather conservative compared to the test results for thermal insulating units.