For masonry buildings with monolithic, highly insulated walls of clay units, no acoustic design according to standard was practically possible under Supplement 1 to DIN 4109:1989. Therefore a design procedure regulated by approvals was introduced in 2010, with which acoustic calculations for a building could be performed with a high security of forecasting. This procedure has been taken up in the completely revised series of standards DIN 4109:2016/2018 "Sound insulation in buildings".The basis for the application of this method is knowledge of the individual sound insulation quantities and joint sound insulation quantities for the relevant clay masonry products or product combinations. In order to simplify performance of the verification for clay masonry buildings, the clay masonry industry provides the program "Modul Schall 4.0" (Acoustic module 4.0), in which the decisive acoustic parameters of external wall products from numerous clay masonry unit producers are stored in a database. In this report, experience of application of the design procedure for clay masonry buildings is presented. There is good agreement between forecasts and tests on completed buildings.
The paper presents results of a series of 6 in-plane shear tests on storey-height clay unit masonry panels [1] with thin-layer mortar, carried out in addition to previous test campaigns [2], [3], and [4]. The walls were constructed with unfilled thermally insulating clay units with a thermal conductivity of lambda = 0.09 W/(m . K). The current design rules for clay unit masonry according to DIN EN 1996-1-1/NA [5] are conservative compared to the presented test results for thermally insulating clay unit masonry.
AbstractIn order to investigate the influence of a partially supported slab on the in‐plane shear resistance of masonry walls, six shear tests on full scale walls were performed at the Chair of Structural Concrete of the University of Kassel in cooperation with ”Arbeitsgemeinschaft Mauerziegel“. The walls were made of large chamber clay masonry units and the depths of the partially supported slabs were different. The large chamber units are typically used for thermally insulated exterior walls, with the slabs only being partially supported. The influence of this constellation is not taken into account in shear capacity assessment according to the current version of Eurocode 6 for Germany. This article describes the test results and provides a comparison with Eurocode 6. In addition, the results of older shear tests on masonry walls made of vertically perforated units with eccentric load application were used.
In order to investigate the influence of a partially supported slab on the in-plane shear resistance of masonry walls, six shear tests on full scale walls were performed at the Chair of Structural Concrete of the University of Kassel in cooperation with "Arbeitsgemeinschaft Mauerziegel". The walls were made of large chamber clay masonry units and the depths of the partially supported slabs were different. The large chamber units are typically used for thermally insulated exterior walls, with the slabs only being partially supported. The influence of this constellation is not taken into account in shear capacity assessment according to the current version of Eurocode 6 for Germany. This article describes the test results and provides a comparison with Eurocode 6. In addition, the results of older shear tests on masonry walls made of vertically perforated units with eccentric load application were used.
The paper presents the results of 20 shear tests on full scale thermal insulating clay unit masonry walls. The types of units used (units with large chambers filled with mineral wool pads and units with small corings filled with mineral wool granulate) as well as the tested wall geometries and vertical loads are representative of the most common wall constructions currently used in housing in Germany. The aim of the investigations was the verification of the shear -resistance of thermal insulating clay unit masonry under realistic conditions and comparison with the design rules in the codes and national technical approvals. The current design rules for clay unit masonry in DIN EN 1996-1-1/NA are rather conservative compared to the test results for thermal insulating units.