• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    D

    Danfoss Inc.

    企业
    180论文总数
    2,706引用总数

    Danfoss(丹佛斯)是丹麦最大的跨国工业制造公司之一,创立于1933年。

    论文量&引用量时间轴

    机构学者

    论文(180)

    年份
    起
    –
    止
    排序
    1Independent Sensorless Control of Dual Three-Phase IPMSM Using Extended Electromotive Force Sliding Mode Observer
    John Gelpud, Sami Ouazine, Ramkrishan Maheshwari

    This paper presents a redundant control scheme for a dual three-phase Interior Permanent Magnet Synchronous Machine (IPMSM) aimed at enhancing system robustness and fault tolerance. A key challenge in achieving independent sensorless control of multiphase machines is the estimation of rotor position and speed without access to the voltages and currents of other winding sets. To address this issue, an Extended Electromotive Force (EEMF)-based Sliding Mode Observer (SMO) is employed. The proposed observer utilizes the stator voltages and phase currents in the $\alpha \beta$ reference frame of each three-phase winding set independently, thereby enabling decoupled control of the dual three-phase motor. The control system is designed and validated through simulations in MATLAB/Simulink and experimentally verified on a 1.5 kW IPMSM drive using rapid control prototyping tools. Both simulation and experimental results demonstrate that the proposed method achieves stable operation up to 2000 rpm and ensures a smooth transition from open-loop to closed-loop control under both load and no-load conditions. Furthermore, the results revealed the presence of torque imbalance between the winding sets. While this imbalance was effectively mitigated in simulation by increasing the execution rate of the speed controller, only partial mitigation was achieved during experimental validation. Index Terms-Dual three-phase IPMSM, sensorless control, extended electromotive force (EEMF), sliding mode observer (SMO), fault-tolerant control.

    20262026 IEEE 22nd International Power Electronics and Motion Control Conference (PEMC)(2026)
    引用
    AI阅读
    加入学术空间
    2Framework for Prediction of Two-Phase R-744 Ejector Performance Based on Integration of Thermodynamic Models with Multiphase Mixture CFD Simulations
    Baris Burak Kanbur,Ekaterini E. Kriezi,Wiebke Brix Markussen, Martin Ryhl Kern,Alexander Busch,Johannes Kristofersson

    Current computational models of two-phase R-744 ejectors require defined outlet pressure conditions for convergence, this brings a strong dependence on experimental data or pre-guessed outlet pressure values. This study presents a framework combining a thermodynamic model and a computational fluid dynamics (CFD) model to predict two-phase R-744 ejector performance, minimizing reliance on experimental data or guessed outlet pressure values. The proposed framework is developed in a broad operating range with 137 different experimental cases from the motive inlet pressure of 51.9 bar to 101.1 bar. Three different approaches are developed for the thermodynamic model in the MATLAB environment; i) a model with global coefficients which are unchanged for the entire operating range, ii) a model with local coefficients, which have unique values for each experimental case, and iii) a model with predicted-local coefficients, which uses a prediction algorithm to find the local values for each experimental case. The local and predicted-local coefficient approaches estimate the mass flow rate from the motive inlet with a relative error of 5 %. However, the mass flow rate predictions from the suction inlet showed high deviations above 30 % for the predicted-local coefficient approach in transcritical operating conditions, while the local coefficient approach keeps the relative error still lower than 5 %. All approaches estimated the ejector outlet pressure with less than 10 % error, which is an acceptable error; therefore, the thermodynamic model-based outlet pressure was defined as the outlet boundary condition to the CFD domain. All thermodynamic model embedded CFD simulations computed the temperature and Mach number values with less than 1 % deviation at the motive nozzle exit. The results show that the prediction algorithm can estimate the ejector outlet pressure within an acceptable deviation range, offering a promising direction for future research to reduce dependence on experimental data.

    2025APPLIED THERMAL ENGINEERING(2025)引用:1
    引用
    AI阅读
    加入学术空间
    3European Initiatives Addressing High Efficiency and Low-Cost Electric Motors for Circularity and Low Use of Rare Resources
    Eric Armengaud, Florian Ratz, Ángela Muñiz,Javier Poza,Fernando Garramiola,Gaizka Almandoz, Jenni Pippuri-Mäkeläinen, Stéphane Clenet,Maarten Messagie, Lea D’amore, Maeva Lavigne Philippot, Oriol Rillo,

    The automotive industry is amidst an unprecedented multi-faceted transition striving for more sustainable passenger mobility and freight transportation. The rise of e-mobility is coming along with energy efficiency improvements, greenhouse gas and non-exhaust emission reductions, driving/propulsion technology innovations, and a hardware-software-ratio shift in vehicle development for road-based electric vehicles. Current R&D activities are focusing on electric motor topologies and designs, sustainability, manufacturing, prototyping, and testing. This is leading to a new generation of electric motors, which is considering recyclability, reduction of (rare earth) resource usage, cost criticality, and a full product life-cycle assessment, to gain broader market penetration. This paper outlines the latest advances of multiple EU-funded research projects under the Horizon Europe framework and showcases their complementarities to address the European priorities as identified in the 2Zero SRIA. Target of this paper is to introduce a family of European projects (EM-TECH, HEFT, MAXIMA, VOLTCAR and CliMAFlux), all following the target of high efficiency and low-cost electric motors for circularity and low use of rare resources. Especially, this paper will describe the latest advances of the respective projects as well as their complementarity to address the 2Zero strategy.

    2025SAE Technical Paper Series(2025)
    引用
    AI阅读
    加入学术空间
    4Multiphase Mixture Simulations of a Specific Two-Phase R-744 Ejector Geometry
    Baris Burak Kanbur,Alexander Busch,Ekaterini E. Kriezi,Wiebke Brix Markussen,Martin Ryhl Kærn,Jóhannes Kristófersson,Jens Honore Walther

    Two-phase carbon dioxide (R-744 or CO2) ejectors are energy recovery devices of the transcritical R-744 vapor-compression refrigeration systems to counteract the energy loss at the throttling stage. However, understanding of the multiphase mixture inside the ejector geometry is complex from the viewpoints of multiphase turbulent mixing, transcritical expansion, and high-velocity flow profile. This study reports on Computational Fluid Dynamics (CFD) simulations for a specific two-phase R-744 ejector geometry with two inlets (motive inlet and suction inlet), a single outlet, and converging-diverging nozzle geometry. Four operationally different cases are investigated, all of them featuring supercritical motive nozzle inlet conditions and saturated or superheated gas suction nozzle inlet conditions. The CFD study is performed in the Simcenter STAR-CCM+ CFD environment using the Two-Phase Thermodynamic Equilibrium Model that represents a coupled multiphase mixture solver for the continuity, momentum, and energy equations for compressible flow phenomena. A comparison of the results with experimental data from the literature shows that the mass entrainment ratio deviates between 3.2

    2024Advances in Computational Heat and Mass Transfer(2024)引用:1
    引用
    AI阅读
    加入学术空间
    5Performance Analysis of an R744 Supermarket Refrigeration System Integrated with an Organic Rankine Cycle
    Ayan Sengupta,Paride Gullo,Mani Sankar Dasgupta,Vahid Khorshidi

    The energy and economic performance of a transcritical R744 booster supermarket refrigeration system with and without parallel compression and integrated with an organic Rankine cycle (ORC) was investigated. The results obtained were compared with those of a transcritical R744 booster supermarket refrigeration system with and without parallel compression and those of a conventional R404A direct expansion (DX) system. Nine different locations, namely Copenhagen (Denmark), Paris (France), Athens (Greece), New Delhi (India), Phoenix and Miami (US), Madrid (Spain), Bangkok (Thailand) and Riyadh (Saudi Arabia), were considered. It was discovered that the ORC is effective only at ambient temperatures higher than 27 °C when operating without parallel compression and 28 °C when operating with parallel compression. By using the heat recovered from the gas cooler to fuel the ORC, the latter was found to be capable of covering between 4% and 24% of the electricity demand of the R744 system in warm and hot climates (without parallel compression). The simple payback period of the additional investment associated with the ORC was found to be between 1.4 and 2.5 years in warm climate locations, while the same was found to be less than about 0.5 years in locations experiencing hot climatic conditions.

    2023ENERGIES(2023)引用:7
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 180 篇论文

    合作机构(88)

    奥尔堡大学合作论文 16
    丹麦技术大学合作论文 11
    南丹麦大学合作论文 6
    Danish Technological Institute合作论文 6
    麻省理工学院合作论文 3
    Rockwool International (Germany)合作论文 3
    阿尔托大学合作论文 3
    西门子合作论文 2
    Austrian Institute of Technology合作论文 2
    Environmental and Water Resources Engineering合作论文 2

    机构统计