This study addresses the lack of quantitative guidance on how operating conditions affect condensation performance in dimpled plate heat exchanger (DPHE) channels, where film evolution and pressure loss are strongly coupled. Transient CFD simulations using a volume-of-fluid (VOF) phase-change model were conducted to investigate R410A condensation in a corrugated single channel of a DPHE. The operating ranges include mass fluxes of 10-50 kg & sdot;m- 2 & sdot;s- 1, wall heat fluxes of 6-16 kW & sdot;m- 2, and inlet superheats of 2-8 K. The results show that increasing mass flux substantially enhances condensate removal and interfacial shear, leading to a marked increase in the area-averaged heat transfer coefficient, while causing a sharp rise in pressure drop. In contrast, wall heat flux and inlet superheat mainly affect the early-stage condensation development, but have limited influence on the quasi-steady thermal-hydraulic performance. A response surface methodology (RSM) based on Box-Behnken design was employed to build surrogate models for heat transfer, pressure drop and the composite performance factor JF, demonstrating excellent statistical fidelity. The optimization results indicate that mass flux is the dominant factor governing JF, and a moderate mass-flux regime is recommended to balance heat transfer enhancement and hydraulic penalty under practical thermal-duty requirements. These findings provide a physics-based operating guideline for DPHE condensers to achieve improved performance with controlled pumping-power demand.
The development of proton exchange membrane fuel cell (PEMFC) technology has led to increased attention being paid to high-power-density stacks based on metal bipolar plates. In the present study, a novel asymmetric wave flow channel was proposed and investigated through a multiphysics simulation, with the aim of improving output performance and mass transfer behavior. The electrochemical, mass-transfer, and distribution properties of the gas channels in several configurations were compared and quantitatively evaluated. The results showed that the PEMFC with an asymmetric wave channel demonstrated superior performance, and the maximum net output power and temperature distribution uniformity were improved by 11.90% and 16.61%, respectively, compared to the basic straight channel. Subsequently, the curve phase, number of wave cycles, blockage occupancy ratio, and amplitudes of the blockages and grooves were individually analyzed. The performance of PEMFCs with asymmetric wave channels can be enhanced by adjusting the curve phase, increasing the number of cycles, increasing the blockage occupancy ratio, and arranging the amplitudes of the blockages and grooves within a reasonable range. Through structural optimization, the oxygen convection flux, and temperature uniformity of the PEMFC increased by 29.74%, and 10.95%, respectively. These findings provide theoretical support for the structural optimization and formation of metal bipolar plates.
Aggregated epidemics, characterized by rapid transmission over short periods, pose severe threats to public health security, necessitating the development of precise source tracing and simulation methods to support efficient prevention and control. However, existing studies suffer from three major gaps: (1) predominant focus on national/regional scales with limited urban-scale analysis; (2) reliance on proprietary mobile data that are often inaccessible; and (3) NP-hard computational complexity in traditional source tracing methods. To bridge these gaps, this paper proposes an integrated spatiotemporal diffusion model comprising two core components: outbreak point estimation and spatial diffusion simulation. The model first uses the SEAIR infectious disease dynamics model to predict trends, combines the 3-Sigma criterion and viral incubation period to screen early epidemiological survey data, employs a road network-constrained DBSCAN algorithm for spatial clustering, and locates the outbreak point via an improved inverse distance weighting method incorporating time and POI density weights. Subsequently, using the estimated outbreak point as the initial transmission center, and based on the “cell-type” living structure hypothesis of populations, it fuses multi-source geographic data to quantify regional attractiveness and simulate viral diffusion in grid space. The model is validated using COVID-19 epidemic data from Xi’an, Shanghai, and the Hong Kong Special Administrative Region of China. Results show that the proposed outbreak point estimation method effectively estimates the initial transmission center, with distances between estimated points and officially announced points of 0.786 km, 1.676 km, and 5.441 km, respectively—shortened by 179 m, 1091 m, and 711 m compared to related studies. The spatiotemporal diffusion model effectively simulates daily incidence patterns, achieving average coverage rates of 67.32% and 72.9% and average precision rates of 60.67% and 78.84% in Shanghai and Hong Kong, respectively, with significantly better simulation accuracy than traditional methods in the early and middle stages of the epidemic. This study provides a scientifically robust, data-parsimonious framework for precise source tracing, early warning, and resource allocation in urban epidemics, with strong generalizability to other resource-limited settings.
With the increasing scale and complexity of Building automation system (BAS), conventional architectures centered on physical controllers are increasingly constrained by limited computing resources, rigid control logic, and poor support for cloud-based intelligence and elastic scheduling. To address these limitations, this paper proposes a cloud-based GMOS Digital Foundation building automation system (GMOS DF-BAS) that upgrades the traditional BAS architecture while maintaining compatibility with existing system ecosystems. The proposed architecture virtualizes the control capabilities of physical controllers into cloud-deployable and dynamically schedulable virtual controllers, and introduces a cross-architecture runtime mechanism that enables legacy control programs to execute seamlessly in cloud environments without code modification. To support large-scale parallel deployment, a container-based virtualization scheme with dynamic resource allocation and port-mapping mechanisms is developed, enabling efficient isolation, elastic scaling, and unified management of multiple control programs. In addition, a dynamic script-based protocol parsing method is designed to support rapid integration and flexible evolution of heterogeneous field protocols. Experimental evaluation and long-term field deployment demonstrate that the proposed system operates stably under different load conditions, achieving an average end-to-end control latency of 105.1 ms, which satisfies real-time requirements of building automation control. Practical engineering validation further shows that the system reduces on-site cabling by 47.37% and achieves an average daily energy-saving rate of 11.17%, while preserving compatibility with existing BAS infrastructures. The research results show that the proposed method can support the evolution of BAS towards cloudification, software-based systems and intelligence, and provides a feasible engineering and technical path for upgrading and transforming existing BAS and establishing a new generation of intelligent building control platforms.
Single-event leakage current (SELC) degradation and damage mechanisms of SILICON carbide (SiC) MOSFETs featuring a reinforced double-trench gate (RDT-MOS) induced by Kr ion irradiation are investigated in this article. During irradiation, the degradation of the drain current consistently exceeds that of the gate current, which differs from the degradation mode observed in planar-gate MOSFETs reported in previous studies. Postirradiation test and failure analysis indicate that the off-state channel current, gate damage, and source trench damage are significant contributors to the leakage current. Finite-element simulation results reveal that the accumulation of holes and the serious current crowding effect at the gate and source trench corners may cause oxide damage and eventually lead to SELC degradation. Furthermore, a SiC double-trench MOSFET with an integrated N-surrounding layer (NSDT-MOS) is proposed to enhance SELC performance. Compared with RDT-MOS, NSDT-MOS can fast extract and recombine radiation-induced holes, thereby reducing the maximum gate oxide electric field and hole concentration at the SiC/SiO2 interface by approximately 88% and 81%, respectively.