This study presents the development of a 3D-printed, wideband, dual-polarized magneto-electric dipole antenna. The proposed antenna demonstrates exceptional cross-polarization isolation (XPI) between its two mutually orthogonal RF ports, achieved through innovative feeding probes, specifically an inverted Gamma-shape and a conventional Gamma-shape probe. The analysis reveals that misalignment between probes can impair XPI; this phenomenon is systematically examined through electromagnetic full-wave simulations. A practical remedy is provided using four plastic rods strategically positioned through the probes and posts. Measurements indicate that XPI exceeds 50 dB across the common operating frequency range of 3.05-4.13 GHz (30%). The maximum realized gain is approximately 7.9 dBi, with a nearly flat response and stable radiation patterns across both ports throughout the bandwidth. The proposed antenna offers a cost-effective, 3D-printed design, wideband radiation performance, and exceptional port-to-port isolation, demonstrating significant potential for full-duplex wireless communication and ICAS applications.
We present the transmission of a 19.2 THz-wide signal covering the S-, C-, and L-bands over a standard-cladding-diameter coupled-core four-core fiber, field-deployed in an underground multi-service tunnel infrastructure in the city of L'Aquila, Italy. The 6.3 km-long link carried 1540 wavelength-division multiplexed spatial super-channels, resulting in an aggregate throughput of 949 Tb/s estimated using generalized mutual information and 888 Tb/s after forward-error-correction decoding. This represents the second-highest throughput reported over any field-deployed optical fiber.
This paper presents a novel, independently controllable dual-polarized reconfigurable intelligent surface (RIS) unit cell for 6G upper mid-band ( 7.125 $7.125$ 7.125 - 24.25 GHz $24.25\,\mathrm{GHz}$ 24.25 G H z ) applications. The proposed unit cell is based on the diagonal placement of mutually orthogonal tunable radiators (loaded with varactor diodes) alongside static dual-polarized radiators. Full-wave electromagnetic simulations of the unit cell demonstrate a phase shift range of 270 ring $270<^>{\circ}$ 270 degrees , a maximum reflection loss of 4.5 dB $4.5\,\mathrm{dB}$ 4.5 d B , and 61 dB $61\,\mathrm{dB}$ 61 d B cross-polarization isolation (XPI) within a 400 MHz $400\,\mathrm{MHz}$ 400 M H z frequency range centered at 15 GHz $15\,\mathrm{GHz}$ 15 G H z . Furthermore, full-wave simulations of a 16 times 16 $16 imes 16$ 16 & times; 16 RIS panel were conducted for various reflection angles under both TE- and TM-polarized illuminations. The results demonstrate a wide-angle beam-steering capability of plus or minus 60 ring $\pm60<^>\circ$ +/- 60 degrees , with a maximum beam-pointing error of only 1.7 ring $1.7<^>{\circ}$ 1.7 degrees . The proposed RIS also exhibits accurate and stable reflection control under wide-angle excitation. A 3 times 3 $3 imes 3$ 3 & times; 3 prototype was fabricated to validate the unit cell's performance. Measurement results agree with the simulations, yielding a 270 ring $270<^>{\circ}$ 270 degrees phase shift, approximately 7 dB $7\,\mathrm{dB}$ 7 d B reflection loss, and 24 dB $24\,\mathrm{dB}$ 24 d B XPI. The proposed RIS is a promising candidate for future 6G communication systems.
We present the characterization of stimulated Raman scattering (SRS) in coupled-core multi-core fibers (CC-MCFs). The Raman gain coefficient measured in field-deployed fibers is consistent with the modeling of SRS in the presence of strong core coupling. The first experimental use of distributed Raman amplification in CC-MCFs is also reported.
We present a compact polymer optofluidic lab-on-a-chip fabricated by maskless laser-direct UV lithography for double-beam photometric detection of nitrite (NO2 -) in water. The chip integrates polymer optical waveguides, a 3 dB coupler, and dual microfluidic cells, implementing on-chip measurement and reference channels that compensate for light-source fluctuations and improve the robustness of the photometric measurements. The system is operated with commercial Griess-reaction-based test kits and standard RGB CMOS image sensors configured for selective RGB-channel absorbance readout. The system achieves a limit of detection of 0.08 mg L-1 of nitrite in reagent-treated standard water samples. These results highlight the potential of low-cost polymer optofluidic chips as portable platforms for nitrite monitoring in drinking water and environmental applications.