
The influence of different brewing conditions on the concentration of the main caffeoylquinic acids (3-caffeoylquinic acid (3-CQA), 4-caffeoylquinic acid (4-CQA), and 5-caffeoylquinic acid (5-CQA)) was investigated. For this purpose, twenty-four coffee brews were extracted and analyzed using HPLC-DAD at 325 nm. Our findings demonstrate the great impact of brewing techniques on the caffeoylquinic acids (CQAs) content. The major isomer was 3-CQA, accounting for about 50% of the total CQAs, followed by 5-CQA and 4-CQA, accounting for about 24-36% for each one. The total content of CQAs was in the range of 45.79 to 1662.01 mg/L, found in iced cappuccino and pod espresso, respectively. In conclusion, this study demonstrates that coffee brews, in particular those prepared using pressurized methods, can be considered as the potential sources of antioxidants such as CQAs.
This paper presents the automatic discrimination of geographical origins of milks from Western Yunnan Plateau areas and eastern China by excitation-emission fluorescence spectrometry and chemometrics. Genuine plateau milks (n=60) and milks from eastern China (n=89) are scanned in the regions of 180–300 nm for excitation and 200–800 nm for emission. Different options of data analysis are investigated and compared in terms of their performance in discriminating milks of different geographical origins: (1) two-way partial least squares discriminant analysis (PLSDA) based on excitation and emission spectra, respectively; (2) two-way PLSDA based on fusion of excitation and emission spectra; (3) three-way PLSDA based on excitation-emission matrix spectra. The two-way PLSDA methods with excitation spectra, emission spectra, and fusion of excitation and emission spectra correctly classify 91.3%, 88.6%, and 95.3% of the milk samples, respectively; while the total accuracy of three-way PLSDA is 96.0%. The results demonstrate the two-way data combining excitation and emission spectra are sufficient to characterize and identify the plateau milks. Considering both model accuracy and the analytical time required, two-way PLS-DA with fusion of excitation and emission spectra is recommended as a reliable and quick method to discriminate plateau milks from ordinary milks.
A flow method of high-performance liquid chromatography (HPLC) seperation and chemiluminescence (CL) detection for sensitive vardenafil analysis in dietary supplements was developed. The vardenafil separation was achieved on a C18 column at 30°C using ethanol-H3PO4 and ethylenediaminetetraacetic acid disodium salt (Na2EDTA) aqueous solution (25 : 75, v/v%) as mobile phase. The followed continuous CL detection was conducted based on the strong CL enhancement by the presence of vardenafil to luminol-K3Fe(CN)6 reaction in alkaline medium. At the flow rate of 0.8 mL/min, the vardenafil retention time (tR) was 6.4 min. Factors that affected the HPLC resolution and CL detection were studied and optimized. The calibration curve obtained for vardenafil standard was linear in concentration range of 8.0 × 10−7 ~ 1.0 × 10−4 mol/L. The relative standard deviations (RSD) of intraday and interday precision were less than 3.5%. The proposed method was applied to the vardenafil determination in oral liquid, wine, and capsule samples.
Acetaldehyde (ethanal) is a genotoxic carcinogen, which may occur naturally or as an added flavour in foods. We have developed an efficient method to analyze the compound in a wide variety of food matrices. The analysis is conducted using headspace (HS) gas chromatography (GC) with flame ionization detector. Using a robot autosampler, the samples are digested in full automation with simulated gastric fluid (1 h at 37°C) under shaking, which frees acetaldehyde loosely bound to matrix compounds. Afterwards, an aliquot of the HS is injected into the GC system. Standard addition was applied for quantification to compensate for matrix effects. The precision of the method was sufficient (<3% coefficient of variation). The limit of detection was 0.01 mg/L and the limit of quantification was 0.04 mg/L. 140 authentic samples were analyzed. The acetaldehyde content in apples was 0.97 ± 0.80 mg/kg, orange juice contained 3.86 ± 2.88 mg/kg. The highest concentration was determined in a yoghurt (17 mg/kg). A first-exposure estimation resulted in a daily acetaldehyde intake of less than 0.1 mg/kg bodyweight from food, which is considerably lower than the exposures from alcohol consumption or tobacco smoking.
A photometric procedure for the determination of ClO(-) in tap water employing a miniaturized multicommuted flow analysis setup and an LED-based photometer is described. The analytical procedure was implemented using leucocrystal violet (LCV; 4,4', 4 ''-methylidynetris (N, N-dimethylaniline), C(25)H(31)N(3)) as a chromogenic reagent. Solenoid micropumps employed for solutions propelling were assembled together with the photometer in order to compose a compact unit of small dimensions. After control variables optimization, the system was applied for the determination of ClO(-) in samples of tap water, and aiming accuracy assessment samples were also analyzed using an independent method. Applying the paired t-test between results obtained using both methods, no significant difference at the 95% confidence level was observed. Other useful features include low reagent consumption, 2.4 mu g of LCV per determination, a linear response ranging from 0.02 up to 2.0 mg L(-1) ClO(-), a relative standard deviation of 1.0% (n = 11) for samples containing 0.2 mg L(-1) ClO(-), a detection limit of 6.0 mu g L(-1) ClO(-), a sampling throughput of 84 determinations per hour, and a waste generation of 432 mu L per determination.
A fast and efficient automated method using a sequential injection analysis (SIA) system, based on the Griess, reaction was developed for the determination of nitrate and nitrite in infant formulas and milk powder. The system enables to mix a measured amount of sample (previously constituted in the liquid form and deproteinized) with the chromogenic reagent to produce a colored substance whose absorbance was recorded. For nitrate determination, an on-line prereduction step was added by passing the sample through a Cd minicolumn. The system was controlled from a PC by means of a user-friendly program. Figures of merit include linearity ( r 2 > 0.999 for both analytes), limits of detection (0.32 mg kg -1 NO 3 -N, and 0.05 mg kg -1 NO 2 -N), and precision (sr%) 0.8–3.0. Results were statistically in good agreement with those obtained with the reference ISO-IDF method. The sampling frequency was 30 hour -1 (nitrate) and 80 hour -1 (nitrite) when performed separately.
One novel electrochemical immunosensor was constructed by immobilizing capture antibody of alpha-fetoprotein (AFP Ab(1)) on a nafion/nanogold-particle modified glassy carbon electrode. With a sandwich immunoassay, one DNA-derived magnetic nanoprobe, simplified as DNA/(ZMPs-HRP-AFP Ab(2))(n), was employed for the detection of AFP. The fabricated procedure of the proposed biosensor was characterized by cyclic voltammetry and electrochemical impedance spectroscopy. The performance and factors influencing the performance of the biosensor were also evaluated. Under optimal conditions, the developed biosensor exhibited a well-defined electrochemical behavior toward the reduction of AFP ranging from 0.01 to 200 ng/mL with a detection limit of 4 pg/mL (S/N = 3). The biosensor was applied to the determination of AFP in serum with satisfactory results. It is important to note that the sandwich nanochainmodified electro-immunosensor provided an alternative substrate for the immobilization of other tumor markers.