    International Journal Of Laboratory Hematology

    International Journal Of Laboratory Hematology

    JournalISSN 1751-5521eISSN 1751-553X中科院 医学 4区

    年发文量

    研究主题

    论文(6871)

    排序
    1Methemoglobin Causes Collapsed WDF Scattergrams and a Low‐ SFL Mature RBC Population in RET Scattergrams on the XR ‐series Automated Hematology Analyzer
    Takahiro Kaido,Yuka Takezawa,Akari Miyazaki,Yuichiro Ide,Nau Ishimine,Yoko Usami

    ABSTRACT Introduction Methemoglobinemia is characterized by increased methemoglobin (MetHb), which impairs oxygen delivery and may cause clinically significant hypoxia. Because CBC testing is more routinely performed than blood gas analysis, abnormalities detected during CBC testing may provide useful clues to unsuspected methemoglobinemia. We investigated the effects of MetHb on scattergrams and optical indices generated by the XR‐Series automated hematology analyzer. Methods MetHb‐containing samples were prepared from five healthy donors using sodium nitrite‐treated red blood cells and analyzed using the XR‐9000. WDF, RET, and PLT‐F scattergrams and WDF sensitivity indices were evaluated. Reference intervals were established using data from 812 individuals in the reference population. Potassium cyanide (KCN) treatment was performed on MetHb‐containing samples from all five donors. Clinical cases were examined. Results Increasing MetHb concentrations reduced side fluorescence (SFL) and produced a collapsed WDF scattergram pattern. SFL reductions were more pronounced in lymphocytes and monocytes than in neutrophils, and LY‐Y and MO‐Y fell below their lower reference limits even at low MetHb concentrations. MetHb induced a distinct low‐SFL population of mature red blood cells in RET and PLT‐F scattergrams, distinguishable even at low MetHb concentrations in the RET channel. KCN treatment restored WDF and RET scattergrams to patterns similar to those of the normal control in all five donors. Similar abnormalities were observed in clinical methemoglobinemia. Conclusion MetHb produces characteristic abnormalities in WDF and RET scattergrams on the XR‐Series analyzer. These findings may provide useful clues for the incidental detection of unsuspected methemoglobinemia during routine CBC testing.

    2026
    引用
    AI阅读
    加入学术空间
    2Rare Case of Metastatic Myxoid Pleomorphic Liposarcoma Involving the Bone Marrow
    Andrew Y. Sung,Sharon K. Germans,Olga K. Weinberg
    2026
    引用
    AI阅读
    加入学术空间
    3Molecular Reclassification Versus Misdiagnosis in Α‐thalassemia
    Fariha Shahid Tanveer, Maham Aleem, Ramsha Irfan
    2026
    引用
    AI阅读
    加入学术空间
    4Optimization of Leukocytic Flags in the Sysmex-XN Series with the Help of Flow Cytometric Differential (flowdiff) Can Significantly Optimize Laboratory Efficiency.
    N. H. Tougaard, S. Pedersen, A. Abildgaard, A. Winther-Larsen,Konstantinos Dimopoulos

    OBJECTIVES The aim of this study was to adjust the default white blood cell (WBC) differential count flag settings on the Sysmex XN-9100 haematology analyser to reduce unnecessary additional leukocyte differential counts without compromising diagnostic sensitivity. METHODS Data from 4554 routine blood samples flagged on Sysmex XN-9100 and corresponding additional leukocyte differential counts performed on the Sysmex XF-1600 flow cytometer were used to optimise the WBC flagging rules. RESULTS A total of 1148 samples had scattergram-related flags, which are non-adjustable. Optimal cut points for Q-flags were established based on Youden's Index for the remaining 3406 samples, while the diagnostic sensitivity of the new flagging rules for acute leukaemia was assessed in a validation cohort. The optimal cut points for Q-flags were 120 for 'Atypical Lymphocytes', 170 for 'Abnormal Lymphocytes' and 160 for 'Blasts', while the Q-flag 'Left shift' offered no diagnostic value in our cohort. The count flags 'eosinophilia', 'basophilia' and 'monocytopenia' were deactivated, as the results from Sysmex XN were comparable to the flow cytometric reference method. By implementing the new flagging rules, 1709 (37.5%) of the samples would have been processed without need for additional leukocyte differential count. When evaluated in a separate validation cohort of 90 samples from patients with newly diagnosed acute leukaemia, the new rules showed similar diagnostic sensitivity to the default flagging system. CONCLUSION Optimisation of Sysmex flagging rules for leukocyte differential counts was feasible and significantly reduced unnecessary reflex testing, while maintaining analytical accuracy and diagnostic safety.

    2026
    引用
    AI阅读
    加入学术空间
    5The Challenging Diagnosis of MYH9 ‐related Disease in the Clinical Laboratory Setting: the Added Value of XN Analyzer–Derived Parameters
    Óscar Fuster,Jordi Tortosa‐Carreres, Luiza Tofan, Ángel Zúñiga,Begoña Laiz‐Marro
    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 6871 篇论文

    高被引作者

    作者引用发文
    Carol Briggs152824
    Gina Zini Tanzi95222
    Benilde Cosmi8166
    Cristina Legnani8166
    Sophie Testa8079
    G. Palareti7723
    Samuel Machin75515
    Giuseppe Lippi74937
    D Poli7472
    Emilia Antonucci7412

    高产作者

    作者引用发文
    Anna Merino18088
    Supan Fucharoen30655
    Catherine P. M. Hayward35552
    Katrien Devreese62452
    Steve Kitchen28151
    Seong-Soo Jang23049
    Angel Molina10543
    Goonnapa Fucharoen9342
    Tracy I. George30440
    José Rodellar20937

    相关期刊

    Acta haematologica
    Annals of Hematology
    International Journal of Hematology
    American Journal Of Hematology
    British Journal Of Haematology
    Transfusion and Apheresis Science
    Hematology, Transfusion and Cell Therapy
    Indian Journal of Hematology and Blood Transfusion
    European Journal Of Haematology
    AMERICAN JOURNAL of HEMATOLOGY-ONCOLOGY