
Conventional Fe(II/III) cyclically mediated Fenton processes exhibit strict acid pH-dependence and excessive iron sludge output due to sluggish Fe(III) reduction. Here, we leverage the intrinsic hydrolysis of Fe(III) to strategically modulate its hydroxyl coordination, achieving efficient contaminant degradation through peroxymonosulfate (PMS) activation. Theoretical and experimental results show that hydroxyl coordination accelerates electron transport from Fe(III) to PMS, lowering the energy barrier for simultaneously generating Fe(IV) and sulfate radical. Moreover, Fe(IV) further oxidizes contaminants with Fe(III) regeneration, promoting sustained and complete PMS decomposition via Fe(III/IV) redox couple. Based on this mechanism, a Fe(III)-cycled Fenton-like process operating under neutral conditions was developed for the effective treatment of actual wastewater without iron sludge output. Techno-economic analysis and life cycle assessment confirm its enhanced economic viability and environmental sustainability compared to the conventional Fenton process. This work provides an iron sludge-free and acid pH-independent Fenton-like oxidation strategy for water decontamination. This study reveals that Fe(III) hydrolysis can establish the Fe(III)/Fe(IV) redox couple to activate peroxymonosulfate under neutral conditions. This enables an iron sludge-free and acid pH-independent Fenton-like process for water decontamination.
Intra-arterial tenecteplase during endovascular treatment (EVT) may increase first-pass recanalization and dissolve microcirculatory thrombi, but its efficacy and safety are uncertain. We hypothesised that this strategy would improve functional outcomes versus EVT alone. This phase 3, randomised, adaptive-enrichment, open-label, blinded-endpoint multicentre study aims to evaluate whether intra‑arterial tenecteplase improves clinical outcomes for patients with acute ischemic stroke. Patients with large‑vessel occlusion eligible for EVT within 24 hours of symptom onset were randomly assigned (1:1) to the tenecteplase group receiving intra‑arterial tenecteplase during EVT or the control group receiving EVT alone. The primary endpoint was favorable functional outcome. Of 380 randomised patients (192 in the tenecteplase group and 188 in the control group), primary outcome data were available for 190 and 186 patients, respectively. Favorable 90-day functional outcomes (modified Rankin Scale 0–2) occurred in 40.0% of the tenecteplase group versus 46.8% of the control group (unadjusted odds ratio 0.76, [95% CI 0.50–1.14], P = 0.19). This work suggests intra-arterial tenecteplase during thrombectomy did not improve 90-day functional outcomes in this population. (Funded by National Science and Technology Major Project and hospital-initiated grants; ClinicalTrials.gov registration: NCT05657444) It is unclear whether adjunct intra-arterial Tenecteplase during thrombectomy improves clinical outcomes in patients with acute large vessel occlusion. Here, the authors show that adjunct intra-arterial tenecteplase during thrombectomy does not improve 90-day functional outcomes in this population.
The clinical effect of adjunctive intra-arterial tenecteplase after successful recanalization in acute basilar artery occlusion (BAO) remains uncertain. In this prospective, randomized, adaptive-enrichment, open label, blinded-end point, multi-center trial, patients with BAO within 24 h of estimated symptom onset who achieved successful reperfusion after endovascular treatment (EVT) were randomized (1:1) to intra-arterial tenecteplase (n = 75) or control (only received standard medical therapy, n = 69). The primary efficacy outcome was independent ambulation (modified Rankin Scale 0–3) at 90 days; the primary safety outcome was symptomatic intracranial hemorrhage (sICH). The trial was stopped early due to safety concerns and lack of efficacy per Data Safety and Monitoring Committee recommendation. Among 144 randomized patients, 143 (99.3%) completed follow-up. At 90 days, independent ambulation was achieved in 40.0% of the tenecteplase group versus 50.0% in the control group (OR 0.67; 95% CI 0.34–1.29; P = 0.23). sICH occurred in 6.2% versus 4.8% (OR 1.31; 95% CI 0.28–6.89; P = 0.73). All-cause mortality at 90 days was 41.3% versus 26.5% (OR 1.96; 95% CI 0.97–4.03; P = 0.063). In this prematurely terminated trial, adjunctive intra-arterial tenecteplase did not improve functional outcomes in patients with BAO. Acute basilar artery occlusion (BAO) is a life-threatening cause of stroke, and whether intra-arterial tenecteplase after successful recanalization leads to improved outcomes is unclear. This randomized trial by Chen and colleagues was stopped early for safety concerns and shows that adjunctive intra-arterial tenecteplase does not improve functional outcomes in acute BAO.
In patients with acute ischemic stroke caused by medium vessel occlusion (MeVO), intra-arterial tenecteplase may offer a targeted strategy to improve recanalization; we hypothesized that intra-arterial tenecteplase would increase successful reperfusion compared with standard care with a comparable safety profile. This phase 2, prospective, randomised, open-label, blinded-endpoint, multicentre study aims to assess the efficacy and safety of intra-arterial tenecteplase for patients with acute ischemic stroke caused by MeVO. Patients with MeVO were randomly (1:1) assigned to receive intra-arterial tenecteplase or standard care. The primary outcome was successful reperfusion of medium vessel occlusion. A total of 80 patients were randomized to either the tenecteplase group (n = 41) or control group (n = 39). Successful reperfusion reached 61.0% (25/41) in the tenecteplase group versus 28.2% (11/39) in the control group (unadjusted odds ratio 3.98, 95% CI 1.56-10.16; P = 0.004). Symptomatic intracranial hemorrhage within 24 h was similar between the tenecteplase and control groups. This work suggests that intra-arterial tenecteplase significantly increased the probability of successful reperfusion compared with standard care, with a comparable safety profile in this stroke population. (Funded by Shenyang Science Tech Project and hospital-initiated grants; ClinicalTrials.gov registration: NCT05657470) Medium-vessel occlusion accounts for a substantial proportion of acute ischemic stroke cases, yet optimal reperfusion treatment strategies remain unclear for patients ineligible for mechanical endovascular thrombectomy. Here, the authors show that intra-arterial tenecteplase significantly increases reperfusion rates for medium-vessel occlusion with acceptable safety, although statistically-significant improvements in 90-day functional outcomes were not detected in this phase-2 randomized trial.
Perovskite light-emitting diodes (PeLEDs) offer exceptional colour purity and efficiency for next-generation display applications. Despite the recent advances in device stability, achieving long-term stable PeLEDs under display-relevant conditions remains a critical challenge. The actual device half-life (T50) experimentally measured for visible PeLEDs were in most cases limited to below 1000 h for any given brightness, in contrast to the much longer extrapolated lifetimes reported. Here, we demonstrate stable green PeLEDs with a T50 lifetime of 1350 h at an initial luminance of 1000 cd m−2 (nits), a maximum energy-conversion efficiency of 28.0%, and a peak external quantum efficiency of 24.5%. The exceptional performance is enabled by the insertion of a fluorinated self-assembled monolayer between the metal oxide and polymeric hole-transport layers. This molecular interlayer leads to Ohmic-like characteristics for charge injection, lowering the operating voltage at ~1000 nits to sub-bandgap levels (~2.1 V) where ion migration is suppressed. The accumulated photon output of our PeLEDs over the course of their T50 lifespan is found to sharply increase as the driving voltage drops to sub-bandgap values, highlighting the critical role of employing low-voltage device architectures in reaching the 1350-h/1000-nit stability milestone. Finally, a flexible active-matrix PeLED display prototype is developed, showing the potential of the devices for wearable optoelectronics. Perovskite light-emitting diodes offer vivid, efficient displays, but long-term stability at practical brightness remains difficult. Yuan et al. add a fluorinated molecular layer to lower voltage, extending device life and enabling a stable flexible perovskite display.