Rationale: Reconstruction of large cranial defects requires an accurate, cost-effective and patient-specific approach, particularly in resource-constrained settings. Patient Concerns: A 44-year-old female with a post-craniectomy cranial defect presented with altered mental status indicative of neurological impairment. Diagnosis: Computed tomography (CT) confirmed an 8.5 cm × 6.5 cm frontoparieto-temporal defect. Treatment: A hybrid workflow combined digital and conventional methods. CT Digital Imaging and Communications in Medicine data were used to fabricate a three-dimensional (3D)-printed skull model. A wax pattern was adapted over it and processed in a customised cranial flask using heat-cured polymethyl methacrylate (PMMA), followed by surgical implantation. Outcomes: Prosthesis fit was assessed intraoperatively, with satisfactory adaptation to the defect margins. At 12 months, the prosthesis remained stable with satisfactory healing and no complications. Take-away Lessons: The proposed hybrid workflow combines the planning advantages of digital 3D printing with the practicality of conventional PMMA processing using a customised cranial flask, providing a cost-effective approach for patient-specific cranial reconstruction in resource-constrained settings.
Abstract Rationale: Mandibular defects complicated by infection and non-union are a challenge to reconstruction and are associated with high failure rates with non-vascularised bone grafts. Patient Concerns: Exposed hardware and difficulty in chewing and speech articulation. Diagnosis: Previously operated case of comminuted mandibular fracture with fracture non-union and exposed implants. Treatment: Debridement of necrotic bone and exposed hardware with recreation of the defect (2.5 cm) and free fibula flap reconstruction for the same. Outcomes: The outcome was measured clinically by uneventful recovery with a well-settled flap, occlusion of the teeth, subsequent improvement in speech and swallowing and radiologically by the duration of bony union at the graft-host junction, which supports a dental implant. Along with this, the patient was also evaluated for UW-QOL (University of Washington, Quality of Life score). Take-away Lessons: Vascularized bone grafting is a valuable option for reconstructing bone defects during secondary reconstruction, even when the defect is small, particularly in cases complicated by infection and nonunion.
Abstract Rationale: Dermoid cysts of the floor of the mouth are rare benign developmental lesions that typically present in young individuals. Patient Concern: We report a 17-year-old male with a long-standing submental and intraoral swelling associated with dysphagia, dysarthria, snoring and positional breathing difficulty. Clinical examination revealed a large midline cystic mass elevating and deviating the tongue, with bilateral submental extension. Airway narrowing was evident on endoscopic evaluation. Diagnosis: Histopathological analysis confirmed a dermoid cyst. Treatment: Due to the size of the lesion and anticipated airway compromise, a prophylactic tracheostomy was performed prior to complete surgical excision via an extra-oral approach. Outcome: The post-operative course was uneventful, with complete resolution of symptoms. Takeaway Lessons: This case highlights the importance of early diagnosis, airway planning and appropriate surgical approach in the management of massive dermoid cysts.
Abstract Introduction: The rehabilitation of localised vertical ridge deficiency in posterior jaws often requires short implants to avoid invasive grafting. However, the influence of implant dimensions on the transition from primary to secondary stability remains a subject of investigation. This study aimed to evaluate and compare the effect of short-wide implants (5.0 mm diameter and 8.0 mm length) versus standard-length implants (4.2 mm diameter and 10.0 mm length) on primary and secondary stability at various time intervals using resonance frequency analysis (RFA). Materials and Methods: Twenty-two implants were placed in healed molar sites (Test group: Short-Wide Implants; Control group: Standard-length Implants). Stability was measured using the Implant Stability Quotient (ISQ) via RFA (Osstell) at placement, 3 weeks, 3 months and 9 months. Data were analysed using Student’s t -test and Repeated Measures analysis of variance ( P < 0.05). Results: In the test group, the mean ISQ increased progressively from 60.10 ± 18.41 (baseline) to 80.70 ± 2.63 (9 months). In contrast, the control group exhibited a significant stability dip at 3 weeks (49.56 ± 12.18) compared to its baseline (56.00 ± 18.12), followed by an increase to 75.89 ± 9.29 at 9 months. The test group showed significantly higher stability than the control at 3 weeks ( P = 0.001) and 9 months ( P = 0.043). Conclusion: Short-wide implants appeared to exhibit a more favourable stability pattern during the observation period; however, larger studies are required to confirm these findings.
Abstract Introduction: Faciomaxillary trauma represents a major surgical workload in tertiary referral centres and poses significant airway challenges due to fracture complexity, oedema, haemorrhage and trismus. Long-term data integrating epidemiology, operative workload and airway strategies remain limited. Materials and Methods: A retrospective audit of operative faciomaxillary trauma cases managed over 19 years was conducted. Demographic variables, fracture patterns, operative procedures, airway techniques and operative workload distribution were analysed. A risk-stratified airway management algorithm was derived. Results: A total of 1266 operative trauma cases were included. Mandibular fractures constituted the largest subgroup, followed by zygomaticomaxillary complex and midface fractures. Nasotracheal intubation was the most frequently employed airway technique, while submental intubation was selectively utilised for complex injuries. The proposed algorithm stratified patients into low-, moderate- and high-risk airway categories. Discussion: This long-term audit highlights evolving trauma patterns, operative burden and airway management strategies. The proposed airway-risk algorithm offers a practical approach for airway planning in resource-variable tertiary-care settings.