
In this work, a modified screen‐printed carbon electrode (SP@SeNPs/SPCE) was developed for sensitive and selective electrochemical sensing of Pb 2+ in real water samples. Selenium nanoparticles (SeNPs) were synthesized via a sustainable sonochemical route using sapodilla ( Manilkara zapota ) peel extract as a natural reducing and capping agent (SP@SeNPs), with synthesis parameters optimized by response surface methodology based on a central composite design. The synthesized SP@SeNPs were characterized by UV–visible spectroscopy, Fourier‐transform infrared spectroscopy, scanning electron microscopy, energy‐dispersive X‐ray spectroscopy, and X‐ray diffraction, to confirm the formation of pure, spherical, crystalline trigonal SeNPs of approximately 38 nm. The SP@SeNPs were drop‐cast onto a SPCE to fabricate an electrochemical sensor (SP@SeNPs/SPCE) for Pb 2+ detection. Using differential pulse voltammetry, the sensor showed a wide linear range from 0.01 to 100 µM with a limit of detection of 0.01 µM, together with high selectivity for Pb 2+ in the presence of common interfering metal ions, and good operational stability and reproducibility. Application to two real water samples gave recoveries in good agreement with inductively coupled plasma optical emission spectrometry, confirming the sensor’s practical utility for trace Pb 2+ monitoring.
Chronoamperometric and electrochemical impedance spectroscopy analyses revealed distinct current responses and interfacial behaviors among the major pilin PilA and the minor type IV pilins PilV and PilX of Acidithiobacillus thiooxidans . Using a custom electrochemical platform functionally analogous to scanning electrochemical microscopy and equipped with copper microelectrodes, measurements were conducted across varying protein concentrations and interelectrode distances. All pilins displayed characteristic chronoamperometric responses with exponential current decay toward steady state; however, PilA sustained electron transport more effectively than PilX, while PilV exhibited intermediate behavior. EIS analyses further discriminated against the proteins, revealing unique Nyquist signatures associated with their electrochemical properties. PilX exhibited the highest charge‐transfer resistance and lowest capacitive response, whereas PilA showed significantly lower interfacial resistance. Notably, PilX demonstrated greater surface coverage on copper electrodes, suggesting stronger adsorption driven by favorable molecular orientation or protein‐surface interactions. Complementary analyses of surface electrostatic potential and hydrophobicity uncovered marked physicochemical differences among the three pilins, highlighting structural features that may govern their assembly, intermolecular interactions, environmental adaptation, and electrochemical performance. Collectively, these results establish that PilA, PilV, and PilX possess specialized electrochemical functions and distinct interfacial characteristics. These properties are consistent with a potential role for individual pilins in electron‐transfer processes at the electrode interface, and suggest that individual pilins may contribute differentially to the conductivity of each pilum. The in vitro polymerization of a pilin could lead to the synthesis of nanowires.
Rapid and reliable detection of SARS‐CoV‐2 RNA remains essential for effective surveillance and early diagnosis of COVID‐19 infection. In this study, a label‐free electrochemical capacitive genosensor was developed for sensitive detection of SARS‐CoV‐2 RNA using a screen‐printed carbon electrode modified with electropolymerized polypyrrole (PPy) and aminophenylboronic acid (APBA). Stable immobilization of the RNA probe was achieved through electrostatic interactions with the conductive polymer matrix and reversible boronate–ribose binding, providing improved probe stability and hybridization efficiency without the need for labeling or amplification steps. Hybridization events were monitored via chronoimpedimetric measurements based on interfacial capacitance changes at the electrode–electrolyte interface. Under optimized conditions in HEPES buffer (50 mM, pH 6.5), the developed genosensor exhibited a rapid response with an optimal hybridization time of approximately 90 s and demonstrated a linear analytical range between 10 and 1000 fM (R 2 = 0.9926 ± 0.0052, n = 5). The limit of detection and limit of quantification were calculated as 3.1 fM and 9.3 fM, respectively, comparable to previously reported amplification‐free electrochemical SARS‐CoV‐2 genosensors. Repeatability studies performed by spiking RNA into serum samples showed minimal matrix interference (~4% deviation from calibration values), with recovery values of 106.2% and 102.1% at 10 and 1000 fM, respectively, confirming satisfactory analytical accuracy. Six biosensors stored at +4 °C or at room temperature in the dark retained 96.9%/91.1% and 87.2%/78.5% of their initial response after 30 and 60 days, respectively, confirming acceptable long‐term stability, more pronounced at +4 °C. These findings demonstrate that the proposed PPy/APBA‐based capacitive genosensor provides a rapid, sensitive, and cost‐effective platform for amplification‐free detection of SARS‐CoV‐2 RNA and represents a promising candidate for point‐of‐care compatible nucleic acid diagnostics.
An electrochemical determination platform was constructed for the identification of circulating tumor DNA (ctDNA) in peripheral blood based on black phosphorene (BPE) integrated with poly(indole‐5‐carboxylic acid) (PIn5COOH). The BPE with large surface area could be combined with the indole‐5‐carboxylic acid (In5COOH) monomers by virtue of physical adsorption, and therefore upgraded the electropolymerization performance and was propitious to the enhancement of the signal response of PIn5COOH. The PIn5COOH/BPE composite with magnificent electrochemical activity was employed as a platform for the identification of DNA fixation and hybridization. The ssDNA probes were covalently combined onto the PIn5COOH/BPE composite, rich in carboxyl groups, through the terminal free amines of the ssDNA probes by way of the 1‐ethyl‐3‐(3‐dimethylaminopropyl) carbodiimide and N‐hydrosulfosuccinimide cross‐linking reaction, alongside the reduction of the self‐signal response. After the hybridization between the probe ssDNA and the target DNA was achieved, the self‐signal response of the composite was regenerated as a result of the formation of the helix construction. The detection limit of the constructed DNA identification platform was 1.8 × 10 −19 mol/L, and the complementary target DNA concentrations ranged from 1.0 × 10 −18 mol/L to 1.0 × 10 −12 mol/L. Simultaneously, the DNA detection platform exhibited favorable selectivity, stability, and repeatability.
As a major physiological hormone, cortisol plays a critical role in the human response to stress and disease, making its accurate and real‐time monitoring highly important for health management and clinical diagnosis. However, the performance of molecularly imprinted polymer (MIP)‐based electrochemical sensors is often limited by the insufficient number of accessible binding sites and inadequate sensitivity, highlighting the need for electrode materials with high surface area and efficient charge/mass transport properties. In this work, a Cu‐MOF‐loaded MXene/rGO aerogel was fabricated and used to modify a screen‐printed carbon electrode, followed by electropolymerization to construct a cortisol‐imprinted electrochemical sensor. The 3D porous MXene/rGO aerogel provided excellent electrical conductivity and a large accessible surface area, while the incorporation of highly porous Cu‐MOF further enhanced the interfacial activity and improved the sensing performance through synergistic effects. Under optimized conditions, the developed sensor exhibited a wide linear detection range of 5 pM–5 μM, an ultralow limit of detection of 0.86 pM, and satisfactory selectivity and stability. In addition, successful quantification of cortisol in artificial saliva demonstrated the feasibility and accuracy of the proposed sensor for practical sample analysis. This work provides an effective strategy for improving the analytical performance of MIP electrochemical sensors and offers promising potential for noninvasive cortisol monitoring.