This study investigates variations in radiofrequency- (RF-) induced energy absorption by orthopedic plates within the human body during 1.5T and 3T magnetic resonance imaging (MRI) scans, considering diverse postures. Using the poseable Duke model, we developed typical postures (O-posture, X-posture, Y-posture, and Z-posture) and placed anatomically correct representations of various orthopedic plates within these postures. Numerical simulations were conducted to evaluate electromagnetic fields and RF-induced energy absorption in these postures near orthopedic plates during MRI scans. Comparing RF-induced energy absorption (peak spatial averaged SAR over 1 g, pSAR1g) in postured models to the original posture reveals substantial variations. The pSAR1g differences for X-posture, Y-posture, and Z-posture reach 48%, 134%, and 32% at 1.5T, and 36%, 83%, and 101% at 3T, respectively. Changing posture can lead to higher or lower pSAR1g. These findings underscore the impact of patient posture on RF-induced energy absorption in orthopedic plates on the ulna bone. The study recommends considering representative body postures in future evaluations for MR conditional labeling of passive implants. Until then, maintaining a neutral posture during MR scans is advised to mitigate unforeseen RF-induced heating risks.
To derive accurate diffusion metrics, both imaging and diffusion-sensitizing gradient pulses should be accounted for when calculating the diffusion-weighted b-matrix. However, it is complex to derive analytical solutions due to complicated interactions between gradient pulses, including orthogonal directions. This study proposes a general framework to calculate the b-matrix automatically (dubbed as Auto-b). Based on the divide-and-conquer approach, the b-matrix calculation is appropriately segmented, and the symbolic mathematical library is applied to handle integration operations for each interval. If the specifications of all gradient pulses are provided to Auto-b, an accurate b-matrix can be obtained. Three examples are explored to validate the accuracy of Auto-b and to detect b-value errors when using approximate calculations. (1) In the conventional spin-echo example, Auto-b exhibits high accuracy, as indicated by the maximum relative deviation of 1.68‰ between its calculated b-matrices and those obtained from analytical expressions. (2) Auto-b is applied to investigate the contribution of imaging gradients to the b-matrix in an optimized spin-echo echo planar imaging sequence at submillimeter resolution. Specifically, ignoring the contribution of imaging gradients results in a b-value error of 12.16 s/mm2 at the 0.8 × 0.8 × 0.8 mm3 resolution and 22.47 s/mm2 at the 0.6 × 0.6 × 0.8 mm3 resolution, respectively, when nominal b = 0. (3) Auto-b is also utilized to analyze the influence of approximate calculations in the spatiotemporally encoded sequence. The results showed that neglecting the contribution of phase-encoding blips causes large b-value errors up to 11.02 s/mm2. In addition, the rectangularization of trapezoidal waveforms led to a high relative b-value error of 39.91%. This study validates the high accuracy of Auto-b and underscores the importance of accurate b-value calculations in both submillimeter imaging and spatiotemporally encoded sequences. Attributed to its automation, accuracy, and broad applicability, Auto-b is helpful for developers of diffusion sequences.
The utility of interleaved odd-number leg birdcage coils is demonstrated for decoupling in double- and triple-tuned multinuclear applications. The birdcage was designed to geometrically decouple from a planar double-tuned (1H-23Na) array and from a 31P saddle coil insert to create a triple-tuned configuration. Comparisons between an actively detuned coil and a purely geometrically decoupled architecture were used to demonstrate the capabilities of the design. In particular cases, the simplicity and adaptability of the interleaved nine-leg design for multinuclear nuclear magnetic resonance (NMR) offer a straightforward alternative to the often complex and lossy designs currently available for multinuclear birdcages and volume coils.
The analysis of human brain fMRI subjects can research neuro-related diseases and explore the related rules of human brain activity. In this paper, we proposed an algorithm framework to analyze the functional connectivity network of the whole brain and to distinguish Alzheimer's disease (AD), mild cognitive impairment (MCI), and cognitively normal (CN). In other studies, they use algorithms to select features or extract abstract features, or even manually select features based on prior information. Then, a classifier is constructed to classify the selected features. We designed a concise algorithm framework that uses whole-brain functional connectivity for classification without feature selection. The algorithm framework is a two-hidden-layer neural network based on extreme learning machine (ELM), which overcomes the instability of classical ELM in high-dimensional data scenarios. We use this method to conduct experiments for AD, MCI, and CN data and perform 10-fold cross-validation. We found that it has several advantages: (1) the proposed method has excellent classification accuracy with high speed. The classification accuracy of AD vs. CN is 96.85%, and the accuracy of MCI vs. CN is 95.05%. Their AUC (area under curve) of ROC (receiver operating characteristic curve) reached 0.9891 and 0.9888, respectively. Their sensitivities are 97.1% and 94.7%, and specificities are 96.3% and 95.3%, respectively. (2) Compared with other studies, the proposed method is concise. Construction of a two-hidden-layer neural network is to learn features of the whole brain for the diagnosis of AD and MCI, without the feature screening. It avoids the negative effects of feature screening by algorithm or prior information. (3) The proposed method is suitable for small sample and high-dimensional data. It meets the requirements of medical image analysis. In other studies, its classifiers usually deal with several to dozens of feature dimensions. The proposed method deals with 4005 feature dimensions.
As part of a homebuilt continuous wave electron paramagnetic resonance (EPR) spectrometer operating at 1.2 GHz, a magnet system for in vivo tooth dosimetry was developed. The magnet was designed by adopting NdFeB permanent magnet (PM) for the main magnetic field generation. For each pole of the magnet, 32 cylindrical PMs were arranged in 2 axially aligned ring arrays. The pole gap was 18 cm, which was wide enough for a human head breadth. The measured magnetic field was compared with the magnetic field distribution calculated in a finite element method (FEM) simulation. EPR spectra of intact human teeth irradiated 5 and 30 Gy were measured for the performance test with the developed magnet system and spectrometer. The measured mean magnetic flux density was estimated to be 44.45 mT with homogeneity of 1,600 ppm in a 2 cm diameter of the spherical volume of the XY plane, which was comparable to the FEM simulation results. The sweep coefficient of the magnetic field sweep coil was 0.35 mT per Ampere in both the measurement and FEM simulation. With ±9 A current, the sweep range was 5.7 mT, which was sufficiently wide to measure the tooth radiation-induced signal (RIS) and reference material. The peak-to-peak amplitude of the measured modulation field was 0.38 mT at the center of the magnet. With the developed magnet fully integrated into an EPR system, the EPR spectra of 5 and 30 Gy irradiated teeth were successfully acquired. The developed magnet system showed sufficiently acceptable performance in terms of magnetic flux density and homogeneity. The EPR spectrum of tooth RIS could be measured ex vivo . The RIS of 5 and 30 Gy irradiated teeth was clearly distinguishable from intact human teeth.
Introduction. In clinical settings, nodular projection (NP) and cord sign (CS) at the tumor edge and irregular nodules (IN) in the mesorectum often appeared together with extramural vascular invasion (EMVI). We aim to evaluate the diagnostic efficiency of the MRI morphology of primary tumor in predicting EMVI in patients with rectal cancer (RC). Methods. This retrospective study included 156 patients with RC. Clinical and imaging factors including NP at the primary tumor’s edge, CS at the primary tumor’s edge, maximal extramural depth (EMD), IN in the mesorectum, growth pattern, tumor length, range of rectal wall invaded (RRWI) by tumor, peritoneal reflex invasion by surgery, and pathology-proven local node involvement (PLN) were evaluated. Then, ROC curve was drawn to depict the meaningful indicators in multivariate analyses. Results. There were 53 (34%) patients with pathological extramural venous invasion (pEMVI). Among the clinical and imaging factors evaluated, NP, CS, IN, EMD, PLN, differentiation, and peritoneal reflex invasion were significantly associated with pEMVI. NP and PLN were independent predictors of EMVI. Areas under the ROC curve (AUC) of NP for prediction of EMVI was 0.82 (95% CI, 0.74–0.90), with a sensitivity of 73.58%, a specificity of 90.29%, a positive predictive value (PPV) of 75.59%, a negative predictive value (NPV) of 86.92%, and an accuracy of 84.62%, respectively. Conclusions. Patients with primary tumor with EMVI usually showed NP and CS. NP was an independent predictor of EMVI and helpful for the diagnosis of EMVI in RC patients.
Purpose. Although full-wave simulations could be used to aid in RF coil design, the algorithms may be too slow for an iterative optimization algorithm. If quasistatic simulations are accurate within the design tolerance, then their use could reduce simulation time by orders of magnitude compared to full-wave simulations. This paper examines the accuracy of quasistatic and full-wave simulations at 3 Tesla. Methods. Three sets of eight coils ranging from 3–10 cm (24 total) were used to measure SNR on three phantoms with conductivities of 0.3, 0.6, and 0.9 S/m. The phantom conductivities were chosen to represent those typically found in human tissues. The range of coil element sizes represents the sizes of coil elements seen in typical coil designs. SNR was determined using the magnetic and electric fields calculated by quasistatic and full-wave simulations. Each simulated SNR dataset was scaled to minimize the root mean squared error (RMSE) when compared against measured SNR data. In addition, the noise values calculated by each simulation were compared against benchtop measured noise values. Results. The RMSE was 0.285 and 0.087 for the quasistatic and full-wave simulations, respectively. The maximum and minimum quotient values, when taking the ratio of simulated to measured SNR values, were 1.69 and 0.20 for the quasistatic simulations and 1.29 and 0.75 for the full-wave simulations, respectively. The ratio ranges, for the calculated quasistatic and full-wave total noise values compared to benchtop measured noise values, were 0.83–1.06 and 0.27–3.02, respectively. Conclusions. Full-wave simulations were on average 3x more accurate than the quasistatic simulations. Full-wave simulations were more accurate in characterizing the wave effects within the sample, though they were not able to fully account for the skin effect when calculating coil noise.
When using ultrahigh-field MR systems (7T), the variations in the RF magnetic field can lead to significant loss in image uniformity. To optimize the overall MR image quality, the image region is divided into multiple smaller regions of interest (the ROIs), which can be independently optimized using transmit array optimization techniques including RF shimming, to improve RF magnetic fields and image intensity. Electromagnetic numerical simulations and corresponding transverse magnetization (|M t |) acquired using the Bloch equation-based MRI simulator are used to evaluate the proposed method. Compared to the simulation results of quadrature driving method, mean and standard deviation (SD) of | M t | in the full image (an inner diameter of 500 mm) were improved 47% (mean) and 48% (SD), whereas 94% (max) and 97% (mean) improved in the unaveraged SAR using the proposed method. The uniformity of | M t | acquired using the method was especially improved in the peripheral region of the selected phantom image compared to that of other methods. The proposed method using multiple independently optimized ROIs and numerical simulations significantly improved the uniformity of | M t | body images at 7T. This technique would be generally applicable to any high-field strength MR systems, which generate short RF wavelengths compared to the field of view.
Plant leaves (Eldar pine (Pinus eldarica M.), fig (Ficus carica L.), and olive (Olea europaea L.)), collected in territories with different ecological conditions, of the Absheron Peninsula (Azerbaijan Republic) were studied by electron paramagnetic resonance spectroscopy (EPR). The generation of nanophase iron oxide magnetic particles in biological systems under the influence of stress factors was revealed. It was found that the process of biomineralization plays a role in the formation of biogenic iron oxide magnetic nanoparticles in plants and the generation of magnetite crystals in biological tissues, and stress factors have a stimulating effect on this phenomenon.
With the objective of improving MR endoluminal imaging of the colonic wall, electromagnetic simulations of different configurations of single-layer and double-layer, and double-turn endoluminal coil geometries were run. Indeed, during colon navigation, variations in coil orientation with respect to B0 are bound to occur, leading to impaired image acquisition due to a loss of signal uniformity. In this work, three typical coil orientations encountered during navigation were chosen and the resulting signal uniformity of the different geometries was investigated through the simulatedB1x,y/IRtvalues. Sampling this quantity over a circle of radius r enabled us to calculate the coefficient of variation (= standard deviation/mean) for this given distance. This procedure was repeated forr∈5;15 mm, which represents the region of interest in the colon. Our results show that single-loop and double-layer geometries could provide complementary solutions for improved signal uniformity. Finally, using four microelectromechanical system switches, we proposed the design of a reconfigurable endoluminal coil able to switch between those two geometries while also ensuring the active decoupling of the endoluminal coil during the RF transmission of an MR experiment.
Phased array (PA) receive coils are built such that coil elements approximate independent antenna behavior. One method of achieving this goal is to use an available decoupling method to decouple adjacent coil elements. The purpose of this work was to compare the relative performance of two decoupling methods as a function of variation in sample load. Two PA receive coils with 5 channels (5-ch) each, equal outer dimensions, and formed on 12 cm diameter cylindrical phantoms of conductivities 0.3, 0.6, and 0.9 S/m were evaluated for relative signal-to-noise ratio (SNR) and parallel imaging performance. They were only tuned and matched to the 0.6 S/m phantom. Simulated and measured axial, sagittal, and coronal 5-ch PA coil SNR ratios were compared by dividing the overlap by the capacitive decoupled coil SNR results. Issues related to the selection of capacitor values for the two decoupling methods were evaluated by taking the ratio of the match and tune capacitors for large and small 2 channel (2-ch) PA coils. The SNR ratios showed that the SNR of the two decoupling methods were very similar. The inverse geometry-factor maps showed similar but better overall parallel imaging performance for the capacitive decoupled method. The quotients for the 2-ch PA coils’ maximum and minimum capacitor value ratios are 3.28 and 1.38 for the large and 3.28 and 2.22 for the small PA. The results of this paper demonstrate that as the sample load varies, the capacitive and overlap decoupling methods are very similar in relative SNR and this similarity continues for parallel imaging performance. Although, for the 5-ch coils studied, the capacitive decoupling method has a slight SNR and parallel imaging advantage and it was noted that the capacitive decoupled coil is more likely to encounter unbuildable PA coil configurations.
Purpose . To revisit the “loopole,” an unusual coil topology whose unbalanced current distribution captures both loop and electric dipole properties, which can be advantageous in ultra-high-field MRI. Methods . Loopole coils were built by deliberately breaking the capacitor symmetry of traditional loop coils. The corresponding current distribution, transmit efficiency, and signal-to-noise ratio (SNR) were evaluated in simulation and experiments in comparison to those of loops and electric dipoles at 7 T (297 MHz). Results . The loopole coil exhibited a hybrid current pattern, comprising features of both loops and electric dipole current patterns. Depending on the orientation relative to B 0 , the loopole demonstrated significant performance boost in either the transmit efficiency or SNR at the center of a dielectric sample when compared to a traditional loop. Modest improvements were observed when compared to an electric dipole. Conclusion . The loopole can achieve high performance by supporting both divergence-free and curl-free current patterns, which are both significant contributors to the ultimate intrinsic performance at ultra-high field. While electric dipoles exhibit similar hybrid properties, loopoles maintain the engineering advantages of loops, such as geometric decoupling and reduced resonance frequency dependence on sample loading.
Ultra-low field magnetic resonance imaging (ULF MRI) is an effective imaging technique that applies the ultrasensitive detector of superconducting quantum interference device (SQUID) sensor to detect the MR signal at a microtesla field range. In this work, we designed and developed a SQUID-based ULF MRI system with a frequency-adjustable measurement field, the performance of which was characterized via water phantoms. In order to enhance the MR signals, a 500 mT Halbach magnet was used to prepolarize the magnetization of the sample prior to excitation. The signal-to-noise-ratio (SNR) of the spin-echo- (SE-) based pulse sequence can reach up to 70 in a single scan. The images were then reconstructed successfully by using the maximum likelihood expectation maximization (MLEM) algorithm based on the backprojection imaging method. It was demonstrated that an in-plane resolution of 1.8 × 1.8 mm2 can be achieved which indicated the feasibility of SQUID-based MRI at the ULF.
Apart from magnetic attraction risks, the primary biophysical concern associated with MRI is radiofrequency heating of the human body and associated discomfort, health deterioration, or potential burns. This paper reviews experimental data and numerical modeling of systemic (core and brain) temperature and local thermal effects associated with diagnostic MRI exposures at 1.5T (64 MHz) and 3.0T (128 MHz). Allowable temperatures and duration of systemic exposure are established based on knowledge of (short-term) human thermobiology. Longer term effects related to DNA damage or altered cellular pathways are not covered in this review. Updated limits are proposed for core temperature increase (≤1.3°C) and for Specific Absorption (<4 kJ/kg). The potential use of thermal dose (CEM43) for local thermal protection is described, and previously proposed exposure limit values are evaluated against available data from current MRI practice. Gaps in knowledge are identified, and recommendations for additional research are provided.
Diffusion-weighted EPI has become an indispensable tool in body MRI. Geometric distortions due to field inhomogeneities are more prominent at large field–of–view and require correction for comparison with T2W TSE. Several known correction methods require acquisition of additional lengthy scans, which are difficult to apply in body imaging. We implement and evaluate a geometry correction method based on the already available non phase-encoded EPI reference data used for Nyquist ghost removal. The method is shown to provide accurate and robust global geometry correction in the absence of strong, local phase offsets. It does not require additional time for calibrations and is directly compatible with parallel imaging methods. The resulting images can serve as improved starting point for additional geometry correction methods relying on feature extraction and registration.
Gaussian mixture model (GMM) was proposed to depict the perfusion volume fraction distribution in the generalized intravoxel incoherent motion model (GIVIM) to improve GIVIM's ability of describing complex perfusion conditions and their changes. Different hepatic perfusion conditions were accounted for by performing different combinations of imaging sequence and diffusion time on six normal livers. In order to evaluate GIVIM-GMM's reliability in perfusion condition analysis, the fitting to diffusion-weighted (DW) data and the consistency between diffusion-related parameters' change and the data's change were tested and the recent GIVIM and the triexponential models were chosen for comparison. The difference of the fitting results was evaluated by performing the extra-sum-of-squares F test and information criteria on normal human DW data. The difference of the consistency was assessed by using two-tailed paired Student's t test. In the extra-sum-of-squares F test, the relative difference ratio F values derived from theGIVIM and GIVIM-GMM and that derived from the triexponential model and the GIVIM-GMM are respectively 25.334 and 27.976, which indicates that significant difference existed and that the GIVIM-GMM provides better fit to the normal human liver DW data. In information criteria test, the evidence ratio values were determined by dividing the GIVIM's or triexponential model's correct probability by the GIVIM-GMM's. Both evidence ratio values (2.3942x10(-10), 8.6167x10(-9), respectively) are much smaller than 1, which also expresses that the best model used to fit the normal human liver DW data was the GIVIM-GMM. In two-tailed paired student's t test, the GIVIM-GMM provides more parameters to give a finer description of perfusion than the triexponential model or GIVIM. In short, all the results demonstrated that the GIVIM-GMM provides better performance than the existing IVIM models for depicting the signal attenuation in DW imaging.
Recording of data other than MR signals are often of interest during MRI. We present unique, versatile circuitry developed for sampling and real-time processing of such non-MR signals to facilitate recording of these by an MR scanner. The circuitry is capable of acquiring multiple signals at 200 kHz sampling rate, measure RF power correlates, perform fast and flexible signal processing, and transmitting both amplitude and frequency modulated RF signals receivable by MR scanners. As an example of use, an electronic point-source signal is generated by the circuitry, and transmitted wirelessly to the receive coil of an MR scanner during an echo planar imaging sequence.
PURPOSE:To identify novel concepts for RF-shim loop architectures suitable for 7T made of two concentric conducting loops fulfilling RF and DC functions, respectively, and to determine their relative SNR performance. The goal is to minimize interference between the two systems while making efficient use of the space closest to the body.THEORY:We show by means of theoretical derivation of the frequency spectrum that the proposed two-loop structure exhibits an anti-resonant null and a resonant peak in the frequency domain.METHODS:The proposed structure is comprised of two concentric wire loops either arranged as nested loops or in the form of a coaxial cable, in which the two conductors carry the RF and shim signals, respectively. We use theory, simulation, and phantom measurements to obtain frequency spectra and SNR maps for the proposed structures.RESULTS:Retained SNR is found to be 75% in the coaxial loop and ranges from 57% to 67% in three different coaxial configurations. We have found both implementations to be a viable concept for the use in RF-shim devices if remaining SNR limitations can be overcome.CONCLUSIONS:We have investigated two new design modalities in 7T RF-shim coil design that separate the RF and shim conductors such that the previously proposed toroidal chokes are eliminated - thereby removing undesired additional loss, bulk, and design complexity.
Introduction Magnetic resonance elastography (MRE) is an MR imaging method for the quantification of spatial stiffness of soft tissues using mechanically induced dynamic shear waves. In some applications, the penetration of shear waves can be limited through attenuation and shadowing of the waves. In order to increase the actuator performance, we present a dual driver approach to compensate for shear wave attenuation and to achieve better coverage over the entire region of interest. Materials and Methods (a) We designed pneumatic turbines that created a sinusoidal centrifugal force due to an eccentric weight. Two turbines were connected in-phase with each eccentric weight having the same angular position relative to its pivot point. (b) We developed a tissue elasticity mimicking abdominal phantom. (c) The phantom served as a test object to investigate the feasibility to generate shear waves at two surface origins with the dual actuator system and to compare it against a single actuation setup. Results and Discussion A stable phase relationship of the shear waves generated by the turbines was achieved as the positions of the eccentric weights were mechanically fixed. The abdominal phantom yielded sufficient MR signal. Liver and rib cage were clearly visible in MR imaging. The shear waves generated by the dual turbine propagated through the region of interest. Our turbine design is reproducible through 3D printing and can be integrated into existing clinical equipment for 1.5 T and 3 T scanners.