
A method is described for the qualitative and quantitative determination of phenylbutazone and oxyphenbutazone in horse urine and plasma samples viewing antidoping control. A horse was administered intravenously with 3 g of phenylbutazone. For the qualitative determination, a screening by HPLC was performed after acidic extraction of the urine samples and the confirmation process was realized by GC-MS. Using the proposed method it was possible to detect phenylbutazone and oxyphenbutazone in urine for up to 48 and 120 h, respectively. For the quantitation of these drugs the plasma was deproteinized with acetonitrile and 20 microliters were injected directly into the HPLC system equipped with a UV detector and LiChrospher RP-18 column. The mobile phase used was 0.01 M acetic acid in methanol (45:55, v/v). The limit of detection was 0.5 microgram/ml for phenylbutazone and oxyphenbutazone and the limit of quantitation was 1.0 microgram/ml for both drugs. Using the proposed method it was possible to quantify phenylbutazone up to 30 h and oxyphenbutazone up to 39 h after administration.
This review article focuses on the specificities of chiral liquid chromatography, with particular emphasis on stability, stereoconversion, enantiomeric separation, recovery and drug concentration determinations. In addition, the paper presents an overview of the different steps which have to be followed for a chiral method to be validated. Sensitivity, selectivity, linearity, precision and accuracy all have to be ensured for three chemical entities, the two enantiomers and the racemate. Only accurate and precise concentrations of the parent drug and its metabolites will lead to the reliable description of their in vitro stability and in vivo body disposition.
High-performance liquid affinity chromatography is a powerful method for the purification of biological compounds owing to its specificity, rapidity and high resolution. In our laboratory, we develop chromatographic supports based on porous silica beads. However, in order to minimize non-specific interactions between the inorganic surface and proteins in aqueous solution, the silica beads are coated with modified dextran. As previously reported, many affinity ligands can be covalently grafted onto dextran-coated silica. In this study, N-acetylneuramic acid, which belongs to the sialic acid family and is present in immunoglobulin G (IgG) epitopes, is used as an active ligand. The interactions of this affinity support and IgG subclasses are analyzed. This immobilized ligand enables purification of IgG3 antibodies.
A high-performance liquid chromatographic (HPLC) assay for a urinary hydroxyproline-containing peptide (hydroxyproline peptide, HypP) is described. This peptide represents about 50% of urinary hydroxyproline-containing peptides. Its concentration and total 4-hydroxyproline (Hyp) concentration evaluated in 325 urine samples have been shown to be closely correlated (r = 0.972; y = 0.499x − 1.5), which may indicate that the two markers provide the same information. The HypP assay, similar to Hyp assay, is carried out without hydrolysis of urine samples. After the blocking of primary amino acids by o-phthaldialdehyde (OPA) and derivatization of secondary amino acids by 9-fluorenylmethyl chloroformate (FMOC-Cl), the FMOC derivatives of HypP and 3,4-dehydroproline (internal standard) were separated on a strong anion-exchange column and detected fluorimetrically. HypP concentration was calculated by measurement of peak-area ratios of HypP and the hydroxyproline standard. The HypP/creatinine (mmol/mol) ratio in fasting urine samples from healthy adults was found to be 8.2 (S.D. = 1.6, n = 33) in 27–44-year-old premenopausal women and 6.9 (S.D. = 1.7, n = 21) in 28–49-year-old men.
A high-performance liquid chromatographic (HPLC) method with ultraviolet (UV) absorbance was developed for the analysis of piperacillin-tazobactam (tazocillin), in plasma and urine. The detection was performed at 218 nm for tazobactam and 222 nm for piperacillin. The procedure for assay of these two compounds in plasma and of piperacillin in urine involves the addition of an internal standard (ceftazidime for tazobactam and benzylpenicillin for piperacillin) followed by a treatment of the samples with acetonitrile and chloroform. To quantify tazobactam in urine, diluted samples were analysed using a column-switching technique without internal standard. The HPLC column, LiChrosorb RP-select B, was equilibrated with an eluent mixture composed of acetonitrile-ammonium acetate (pH 5). The proposed technique is reproducible, selective, and reliable. The method has been validated, and stability tests under various conditions have been performed. Linear detector responses were observed for the calibration curve standards in the ranges 5–60 μg/ml for tazobactam, and 1–100 μg/ml for piperacillin and spans what is currently though to be the clinically relevant range for tazocillin concentrations in body fluids. The limit of quantification was 3 μg/ml for tazobactam and 0.5 μg/ml for piperacillin in plasma and urine. Extraction recoveries from plasma proved to be more than 85%. Precision, expressed as C.V., was in the range 0.4–18%.
Validations of analytical methods are important for the generation of data for bioavailability, bioequivalence and pharmacokinetic studies. It is essential to use well defined and fully validated analytical methods to obtain reliable results that can be satisfactorily interpreted. This manuscript is intended to provide guiding principles for the evaluation of a method's overall performance. For this purpose, all of the variables of the method are considered, including sampling procedure, sample preparation, chromatographic separation, detection and data evaluation. The criteria considered are as follows; stability, selectivity, limits of quantification and of detection, accuracy, precision, linearity, recovery and ruggedness. Models used for analytical calibration curves are explained in term of validity and limitations, along with a presentation of the most common statistical considerations used to validate the model. Appropriate means of testing precision and accuracy, the most important factors in assessing method quality, are presented. Other issues, such as re-validation, cross-validation, partial sample volume, endogenous drugs and biological matrix of limited availability, are also discussed.
A method for separating and detecting retinoids by reversed-phase capillary liquid chromatography with amperometric electrochemical detection is described. Packed columns with an inner diameter of 180 μm were employed for the separation using a C18 stationary phase and a mobile phase containing acetonitrile-water-methanol (65:32.5:2.5, v/v/v) with 1% tetrabutylammonium perchlorate and 0.174 M acetate buffered at pH 5. The detection cell consisted of a carbon fiber barrel electrode held at 0.9 V versus an Ag/AgCl reference. Injection volumes of 2 μl produced detection limits of 2.73, 0.472, 0.428, and 0.267 fmol (or 410, 64.1, 60.9, and 38.2 pg ml−1) for 13-cis-retinoic acid, all-trans-retinoic acid, retinaldehyde, and retinol, respectively. This represents an improvement in detection limits of at least three orders of magnitude for similar analyses using liquid chromatography and UV absorbance detection. The detector signal was linear over two orders of magnitude of analyte concentration. Retinoid concentrations in bovine serum were determined and found to be in good agreement with previously reported values.
An analytical investigation of a new peptide family, the human galanins and their fragments, was carried out by reversed-phase HPLC, capillary zone electrophoresis (CZE) at different pH values and micellar electrokinetic capillary chromatography (MECC) in phosphate-borate-sodium dodecyl sulphate buffer. None of the methods seems to be superior to the others. The complementary nature of the electrophoretic methods is obvious when the profiles of peptides are compared; impurities not separated by HPLC are separated by CZE or MECC and vice versa. With these three different separation methods, a more complex analytical control of the synthetic work can be achieved.
A sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of a benzonaphthazepine antipsychotic agent, SCH 39166, and its active metabolite, SCH 40853. The HPLC method required a single-step organic extraction at alkali pH followed by HPLC analysis utilizing a CN column with UV detection at 205 nm. The limit of quantitation was 1 ng/ml for SCH 39166 and 0.5 ng/ml for SCH 40853. The HPLC method was cross-validated with a previously reported GC method by the analysis of 73 plasma samples spiked with various concentrations of SCH 39166 and SCH 40853. The correlation coefficient was 0.9969 for SCH 39166 and 0.9984 for SCH 40853. Both GC and HPLC methods were used for the determination of plasma concentrations and yielded similar pharmacokinetic parameters for SCH 39166 and SCH 40853 in man following oral administration of SCH 39166 (100 mg).