
The Toroidal Magnetized System device has been significantly upgraded to enable development of various wall conditioning techniques, including methods based on ion and electron cyclotron (IC/EC) range of frequency plasmas, and to complement plasma-wall interaction research in tokamaks and stellarators. The toroidal magnetic field generated by 16 coils can reach its maximum of 125 mT on the toroidal axis. The EC system is operated at 2.45 GHz with up to 6 kW forward power. The IC system can couple up to 6 kW in the frequency range of 10 MHz-50 MHz. The direct current glow discharge system is based on a graphite anode with a maximum voltage of 1.5 kV and a current of 6 A. A load-lock system with a vertical manipulator allows exposure of material samples. A number of diagnostics have been installed: single- and triple-pin Langmuir probes for radial plasma profiles, a time-of-flight neutral particle analyzer capable of detecting neutrals in the energy range of 10 eV-1000 eV, and a quadrupole mass spectrometer and video systems for plasma imaging. The majority of systems and diagnostics are controlled by the Siemens SIMATIC S7 system, which also provides safety interlocks.
This work presents an overview of the integrated strategy developed, as part of the DEMO Key Design Integration Issue 1 (KDII1), to protect the EU-DEMO first wall (FW) from planned and unplanned plasma transients by employing discrete limiters. The present Breeding Blanket (BB) FW design, which aims at minimizing the loss of neutrons while travelling to the breeding zone, is able to withstand steady state heat fluxes up to ≈1-1.5 MW/m² [1], which is not sufficient to guarantee its integrity for most plasma-FW direct contact. This is different from ITER, which has a FW designed for peak heat loads up to 4.6 MW/m2 [2], and it does not have the DEMO BB breeding related requirement. A series of documents was compiled in the DEMO Pre-Conceptual Design Phase, in support of the KDII1. The work presented here was presented at the 2020 DEMO Gate 1 (G1) review, and collects also the comments of the panel and the relative additional studies triggered by them. The design process, presented in this paper was adopted to systematically evaluate the impact of design changes, or new physics inputs, on the FW protection strategy and integration issues. It includes compiling the list of transients, and performing the relative plasma simulations, the design of discrete limiters and the evaluation of their capability to reduce the heat flux density on the FW, and finally a preliminary analysis of the heat loads effects on the Plasma Facing Components (PFC). All these aspects, together with preliminary limiter design, where considered since the beginning, in an integrated way.
Infrared (IR) diagnostics are used to measure plasma-facing components (PFC) surface temperature in fusion devices. However, the interpretation of such images is complex in all-reflective environments because of unknown emissivity and multiple reflections issues. In order to assess these challenges an iterative inversion method based on a fast photonic model, the radiosity method, has been developed. This method is applied to two different direct models based on different geometries, Sec-Tore and RADIOS, in order to estimate temperatures from experimental-like data simulated with a Monte Carlo ray-tracing code with diffuse reflective surfaces or specularly reflective surfaces. RADIOS allows retrieving temperature on colder targets (lower than 200°C) with errors of 33% and the peak temperatures with errors of 6%.
Wendelstein 7-X (W7-X) is the leading experiment on the path of demonstrating that stellarators are a feasible concept for a future power plant. One of its major goals is to prove quasi-steady-state operation in a reactor-relevant parameter regime. The surveillance and protection of the water-cooled plasma-facing components (PFCs) against overheating is fundamental to guarantee a safe steady-state high-heat-flux operation. The system has to detect thermal events in real-time and timely interrupt operation if it detects a critical event. The fast reaction times required to prevent damage to the device make it imperative to automate fully the image analysis algorithms. During the past operational phases, W7-X was equipped with inertially cooled test divertor units and the system still required manual supervision. With the experience gained, we have designed a new real-time PFC protection system based on image processing techniques. It uses a precise registration of the entire field of view against the CAD model to determine the temperature limits and thermal properties of the different PFCs. Instead of reacting when the temperature limits are breached in certain regions of interest, the system predicts when an overload will occur based on a heat flux estimation, triggering the interlock system in advance to compensate for the system delay. To conclude, we present our research roadmap towards a feedback control system of thermal loads to prevent unnecessary plasma interruptions in long high-performance plasmas.
This paper presents the testing campaign of the two First Wall mock-ups in the HELOKA facility, one mock-up having a 3 mm thick Oxide Dispersion Strengthened (ODS) steel layer on its surface and the other featuring a tungsten functionally graded cover. Special consideration is given to the diagnostics used for these tests, in particular, the measurement of the surface temperature of the tungsten functionally graded layer with an infrared camera. Additionally, the paper looks into the uncertainty associated with the calorimetric evaluation of the applied heating power for these experiments.
In recent years a strong effort has been made to investigate disruption avoidance schemes in order to aid the development of integrated operational scenarios for ITER. Within the EUROfusion programme the disruptive H-mode density limit (HDL) has been studied on the WPTE (Work Package Tokamak Exploitation) devices ASDEX Upgrade, TCV and JET. Advanced real-time control coupled with improved real-time diagnostics has enabled the routine disruption avoidance of the HDL. This allowed the systematic study of the influence of various plasma parameters on the onset and behavior of the HDL in regimes not easily accessible otherwise. The upper triangularity delta(top) is found to have a significant influence on the x-point radiator (XPR), which plays a major role for the evolution of the disruptive HDL. At high delta(top) the gas flow rate at which the onset of the XPR occurs is strongly reduced compared to low delta(top) . The reduction of delta(top) has proven to be an effective actuator for the HDL disruption avoidance on ASDEX Upgrade for highly shaped scenarios ( delta(top)>0.25 ). It is observed that the occurrence of the XPR and the H-L transition at the density limit are two separate events, the order of which depends on the applied auxiliary heating power. At sufficiently high heating power the XPR occurs before the H-L transition. Impurity seeding, used for divertor detachment, influences the onset and the dynamics of the XPR and the behavior of the HDL. The stable existence of the XPR, which is thought to be a requirement for detachment control in future devices, has also been observed without impurity seeding. The implementation of a robust and sustainable operational scenario, e.g. for ITER, requires the combination of continuous control and exception handling. For each disruption path the appropriate observers and actuators have to be validated in present devices. Automation of the dynamic pulse schedule has proven successful to scan the operational space of the HDL without disruption. Applying such a technique to ITER could reduce the machine risk induced by disruptions during commissioning. The methodology to develop physics-based observers, which indicate the entry into a disruption path well in time, and applying the appropriate action before the discharge becomes unstable has proven successful.
Design basis accidents are investigated continuously for the European DEMO reactor accompanying its development. One selected postulated initial event (PIE) is a loss of vacuum (LOVA) in vacuum vessel (VV) with large ingress of air induced by rupture in a VV penetration. It has been investigated for the helium cooled pebble bed (HCPB) blanket concept according to the DEMO baseline 2017. The associated primary heat transfer system (PHTS) and the related systems in the tokamak building, from the VV to the PHTS vault and galleries, are considered for the investigation. The LOVA is postulated to occur at a port seal of the electron cyclotron equatorial port plug on the side of the closure plate with (i) a small leak of 1.0 × 10 −3 m 2 , or (ii) a large break size of 1.0 × 10 −2 m 2 . Air ingress from one port cell into the VV leads to the VV pressurization and the fusion power termination followed by an unmitigated plasma disruption. A loss of off-site power for 32 h is assumed to coincide with the disruption. An in-vessel loss of coolant accident (LOCA) is considered as a consequence if the affected first wall (FW) reaches the defined temperature of 1000 °C. The radioactive inventories in the VV (tritium, W-dust) can mobilize towards the VVPSS, the affected systems in the building and the environment due to pressurization, venting and leak conditions. MELCOR 1.8.6 for fusion is applied for this deterministic safety analysis. The resulting releases of radioactivity to the environment are then provided for dose calculation using the computer systems UFOTRI and COSYMA. Outcomes of this LOVA analysis are critically discussed: the transient evolutions of different cases are compared; hydrogen production is detected in case of aggravating FW failure; the source terms (tritium, W-dust) are transported to the connected systems; and the dose results from the environmental releases are provided.