
Unloading caused by the excavation of foundation pit will lead to the deformation of the surrounding strata and the adjacent metro structures. Excessive structural deformation will threaten the normal metro operation and even the safety of the subway, so effective deformation control measures are indispensable. This study takes a deep excavation project neighboring two operating metro lines in Shanghai as an example and the deformation control techniques of foundation pit excavation are introduced. Overall, the plane division excavation is adopted to reduce the exposed length and the time-space effect of the foundation pit. In order to effectively control the deformation of the enclosure structure adjacent to the subway, the high-stiffness diaphragm walls are utilized as the retaining structure along the metro sides and the concrete axial force servo system is adopted for the second strut to achieve active deformation control. Meanwhile, triaxial cement-soil mixing pile reinforcement is arranged inside the pit to enhance the resistance of the passive soil zone. Furthermore, some of the diaphragm walls deepen as penetrating curtain to control the adverse environmental impacts of dewatering of micro-confined aquifer. The deformation of diaphragm walls and the metro structures is monitored and analyzed. The result shows that the maximum displacements of the diaphragm walls and the metro structures are 15.7mm and 4.8mm, respectively, both complying with the relevant deformation control standards and verifying the effectiveness of the proposed deformation control methods.
The production of ordinary Portland cement (OPC) is associated with substantial CO 2 emissions, while reinforced concrete structures exposed to marine or deicing-salt environments require improved resistance to chloride-induced deterioration. Although supplementary cementitious materials (SCMs) and fine mineral powder (FMP) have been used to reduce cement consumption, further clarification is needed regarding how binder composition and curing condition jointly influence strength development, shrinkage, carbonation, chloride binding, and chloride transport. This study investigated the mechanical properties and chloride penetration resistance of low-carbon concrete with blended binder systems incorporating ground granulated blast-furnace slag (GGBS), fly ash (FA), silica fume (SF), and FMP. Concrete mixtures with design compressive strength levels of 30 and 45 MPa were prepared using OPC, GGBS, and FA binder systems with FMP substitution, and an 80 MPa ternary binder mixture containing FA and SF was also examined. The experimental program included compressive strength, flexural strength, splitting tensile strength, static modulus of elasticity, drying shrinkage, accelerated carbonation, salt-water immersion, water-soluble chloride, total chloride, chloride binding ratio, and apparent chloride diffusion coefficient evaluations. The results showed that FMP substitution increased compressive strength, reduced carbonation rate coefficients, increased chloride binding ratio, and decreased the apparent diffusion coefficient, particularly in blended binder systems. These findings indicate that optimized blended binder systems can contribute to low-carbon concrete with enhanced durability in chloride-bearing environments, provided that mechanical performance, dimensional stability, carbonation resistance, and chloride binding capacity are considered together.
Tropical residual soils constitute the predominant natural foundation and construction materials in many tropical regions of the world, particularly in Nigeria, where they are widely utilized in road construction, building foundations, embankments, and other civil engineering works. Despite their abundance and economic advantages, the engineering performance of these soils varies considerably due to differences in parent rock composition, weathering intensity, climatic conditions, and mineralogical characteristics. Inadequate characterization and improper utilization of these soils have contributed significantly to numerous cases of structural distress, pavement deterioration, and foundation failures. This study investigates the physical, index, and mechanical properties of tropical residual soils collected from selected locations in Edo State, Nigeria, namely Auchi, Ikpeshi, and Igarra, with the objective of assessing their suitability for multipurpose structural and geotechnical applications. Comprehensive laboratory investigations were carried out, including determination of natural moisture content, particle size distribution, Atterberg limits, specific gravity, compaction characteristics, California Bearing Ratio (CBR), and direct shear strength parameters. The results revealed relatively low natural moisture contents ranging from 4.14% to 9.69%, non-plastic to slightly plastic characteristics, satisfactory specific gravity values, and moderate shear strength properties. The soils exhibited varying load-bearing capacities and compaction responses depending on their geological origin and location. Although the materials generally demonstrated acceptable engineering properties for light- to medium-duty construction applications, a noticeable reduction in strength and bearing capacity was observed under soaked conditions, indicating susceptibility to moisture-induced performance deterioration. Consequently, the study emphasizes the importance of adequate compaction, effective drainage systems, and where necessary, soil stabilization measures to enhance long-term performance. The findings provide valuable site-specific geotechnical data and practical recommendations for the sustainable utilization of tropical residual soils in foundation engineering, pavement construction, and other multipurpose infrastructure projects within tropical environments.
Hybrid fibre-reinforced concrete is an effective approach for improving the mechanical performance, deformation capacity, and durability of concrete by combining fibres with complementary mechanical characteristics. Basalt fibres provide high stiffness and tensile strength, whereas polypropylene fibres contribute to crack control and post-cracking deformation. However, the combined influence of total hybrid fibre volume and fibre proportion on the mechanical and durability performance of polypropylene-basalt hybrid fibre-reinforced concrete requires further investigation. Therefore, this study experimentally evaluates the mechanical and durability properties of M40-grade polypropylene-basalt hybrid fibre-reinforced concrete with different total fibre volume fractions and fibre proportions. Twelve hybrid mixtures were prepared by varying the total fibre volume from 0.25% to 1.0% and the polypropylene-to-basalt fibre ratio as 25:75, 50:50, and 75:25, along with a plain concrete control mix. Compressive and flexural strengths were evaluated at 3, 7, 28, and 90 days, while splitting tensile strength and water absorption were assessed at 28 days. Compressive stress-strain behaviour and deformation characteristics were also examined. The results showed that compressive strength was most effective at low to moderate fibre contents of 0.25-0.50%, particularly in basalt-rich mixtures, whereas higher fibre contents reduced compressive strength because of fibre interaction, reduced workability, and dispersion limitations. Flexural strength and deformation capacity improved substantially with hybrid fibre incorporation, with basalt-rich mixtures providing higher peak strength and polypropylene fibres contributing to post-cracking deformation. The 28-day splitting tensile strength increased by nearly 30% at 0.75% total fibre volume in the basalt-rich mixture. Water absorption progressively decreased with increasing fibre content, reaching a minimum of 1.07% at 1.0% total fibre volume in the basalt-rich mixture. Overall, polypropylene-basalt hybridisation effectively balances strength, ductility, tensile resistance, and durability, with the optimum fibre content depending on the targeted performance requirements.
This study evaluates the lateral-load performance of a highly slender, 90-storey reinforced-concrete high-rise building under three structural configurations, focusing on serviceability, global stiffness and force demand. The building has a nominal height of 310.50 m, a plan width of 24 m and a height-to-width ratio of 12.9375. Case 1 is a reference multiple-tube structure without outriggers. Case 2 incorporates outriggers at the 30th and 60th floors. Case 3 retains the outriggers and revises the beam dimensions from 400 × 600 mm to 600 × 600 mm and column dimensions from 600 × 600 mm to 900 × 1200 mm. The configurations were analysed using ETABS, with wind and seismic actions considered in accordance with IS 875 (Part 3) and IS 1893 (Part 1), respectively. Performance was compared using maximum storey displacement, drift ratio, upper-level acceleration, modal periods, earthquake and wind base shear, overturning moment and modal response. Maximum displacement decreased from 1039.431 mm in Case 1 to 900.385 mm in Case 2 (13.38% reduction) and 615.833 mm in Case 3 (40.75% reduction). Maximum drift ratios were 0.001057, 0.000957 and 0.000784, respectively; the Case 3 reduction relative to Case 1 was 25.83%. Story 90 accelerations decreased from 0.210 m/s 2 to 0.193 m/s 2 and 0.151 m/s 2 , respectively. The fundamental period declined from 12.093 s to 11.315 s and 10.301 s, indicating increased global stiffness. Under EQX loading, base shear increased from 23,232.83 kN to 23,467.89 kN and 27,797.57 kN, while wind base shear decreased from 35,064 kN to 34,552 kN and 33,865 kN. Base overturning moment increased from 5.431 × 10 6 kN·m in Case 1 to 5.477 × 10 6 kN·m and 6.487 × 10 6 kN·m. Case 3 provided the greatest reductions in displacement, drift and acceleration, but its higher seismic base shear and overturning demand require careful verification of member and foundation capacities.