A rapid determination of estradiol is formed. Estradiol Molecular Imprinting Technology, silicon magnetic composite and UV-Visible spectrometry are well applied in this technique. Silicon magnetic composite is modified by Molecular Imprinting Technology,estradiol imprints on the layer successfully. The modified magnetic composite has a specific binding with estradiol. The complex is treated by eluent, the eluent is determinated at 280 nm by UV-Visible spectroscopy. Rapid determination of estradiol is realized ultimately. In the analyses of estradiol in milk powder, limit of this research is 1.25 μg/kg, recovery reaches 99.6% in lower concentration.
通过稳定性研究计算鱼饲料基体标准样品的保存寿命或有效期.由最小二乘法线性回归标准样品多时间点的特性值(粗蛋白质、镉)和时间的函数关系,采用t检验证明稳定性数据无显著趋势,并采用代数法或图解法计算所研制标准样品的有效期,最终得到鱼饲料分析基体标准样品的有效期为4年.
目的:建立用电感耦合等离子体质谱(ICP-MS)法测定辽宁地区大米及其种植土壤中铬、镉、铅、砷、汞、铜、锌、镍8种重金属含量的方法.方法:微波消解法处理样品,采用ICP-MS法测定,射频功率1 500 W,采用氦气碰撞模式,载气为氩气,载气流速0.7 L·min-1,等离子体气体流速15.0 L·min-1,泵速0.3r·s-1.结果:8种重金属线性关系良好(r>0.995 0);加样回收率为85.0%~96.1%(n=6);检测限为0.001~0.05mg·kg-1.结论:本方法准确可靠、灵敏简便,可用于大米及其种植土壤中多种重金属的质量研究,同时为测定同类基质中此8种重金属提供参考.
目的:建立微波消解-原子荧光光谱法测定参苓白术丸中汞的含有量.方法:4批样品微波消解后,用原子荧光光谱法测定汞的含量.结果:汞在0~2.5ng/ml(r=0.9999)内线性关系良好,方法定量限为0.001mg/kg,平均回收率为85~94%,相对标准偏差为2.6%~3.4%,柑橘叶成分分析标准物质汞的测定值均在真值的区间范围内,RSD为3.7%.结论:本研究建立的微波消解-原子荧光光谱法测定参苓白术丸中汞的检测方法准确、可靠,适用于参苓白术丸中汞含量的测定.
本文在查阅我国现行火焰原子吸收光谱法测定钠中铯盐用量的基础上,对《水质钾和钠的测定火焰原子吸收分光光度法》(GB 11904-1989)[1]中硝酸铯加入量进行探究,优化了硝酸铯加入量,建立上机样品中硝酸铯用量由0.60 g/L减量至0.20 g/L的新方法.应用此方法与标准方法同时测定地表水和饮用水,结果显示两种方法的测定结果没有显著差异.