
Purpose: To evaluate the long-term prognostic value of a biomarker-guided implant risk tool in predicting the occurrence of peri-implantitis. Materials and methods: From a pool of private implant patients enrolled in a supportive care programme for at least 10 years, 80 partially edentulous subjects were recruited and evaluated retrospectively. A prognostic score was estimated based on the area under the curve for receiver operating characteristic including 95% confidence intervals. Analyses were performed at the patient level. Results: The mean implant follow-up period was 10.5 years. Incidence of peri-implantitis was 17.5%. The percentage of cases at high risk of peri-implantitis according to the biomarker-guided implant risk tool was 27.6%. The area under the receiver operating characteristic curve for the biomarkerguided implant risk tool was 0.836 for peri-implantitis events. A high biomarker-guided implant risk score was significantly associated with incidence of peri-implantitis, with a hazard ratio of 4.8. Conclusion: The biomarker-guided implant risk tool might represent a promising means to assess patients at high risk of developing peri-implantitis.
Purpose: Autogenous bone chips are a key component of augmentative and periodontal surgical reconstruction. The choice of an appropriate bone scraper can influence efficiency, effectiveness and user satisfaction. The aim of this non-randomised clinical cadaver-based usability pilot study was to compare the Safescraper (META, Reggio Emilia, Italy) with the newly developed Bone Gainer (PalDent Tech, Berlin, Germany) in terms of usability. Materials and methods: In collaboration with the Department of Oral and Cranio-Maxillofacial Surgery at the University Hospital Basel, 16 users with varying levels of experience evaluated the performance of both instruments on human cadaver heads in the posterior maxilla during a lateral fenestrating antrostomy. The summative evaluation used a 25-item Likert questionnaire covering the domains of ergonomics, perceived effectiveness, perceived efficiency, satisfaction and overall assessment. Paired Wilcoxon tests were used and effect sizes (r) were calculated. Results: The Bone Gainer was rated significantly better than the Safescraper across most domains (P < 0.01), except for the criteria "can be used without instruction" and "initial blade sharpness". Effect sizes were consistently large (r "z: 0.82 to 0.86). Conclusions: The results indicate that the choice of instrument may significantly influence perceived usability and subjective user experience. Because this is a cadaver pilot study without clinical endpoints, its applicability to everyday patient care remains limited. Future studies should validate the observed differences in clinical settings and assess their significance for surgical outcomes.
Purpose: To assess patients' knowledge, attitudes and experiences regarding peri-implantitis in a university-based clinical setting and compare findings across general dentistry, periodontics and prosthodontics clinics to identify gaps in patient understanding. Materials and methods: A cross-sectional survey was conducted among 306 patients from the School of Dentistry, University of Michigan (general dentistry 104; prosthodontics 100; periodontics 102). Participants completed questionnaires covering oral hygiene habits, awareness of implants and peri-implantitis, risk factors, treatment options and satisfaction with care. Descriptive statistics, logistic regression and intergroup comparisons were performed to analyse responses. Results: Although 79% of participants were familiar with dental implants, only 32% were aware of peri-implantitis and its management. Patients treated in periodontics and prosthodontics clinics were more likely to report having received information about dental implants compared to those in general dentistry (P < 0.05). Female participants demonstrated greater awareness of risk factors and treatment options than male participants (P < 0.05). Although most patients recognised the importance of maintenance care, knowledge regarding complications and contributing factors remained limited. Conclusion: Within this university-based population, a substantial gap in patient awareness and understanding of peri-implantitis persists despite general familiarity with dental implants. These findings highlight the need for improved patient education and communication strategies to support preventive care and long-term implant maintenance.
Purpose: To evaluate the medium-term clinical, radiographic and aesthetic outcomes of polished-collar implants placed with simultaneous horizontal guided bone regeneration and transmucosal healing after a minimum follow-up period of 3 years. Materials and methods: Patients treated with implant placement and simultaneous guided bone regeneration between January 2021 and November 2022 were screened. Inclusion criteria included placement of a polished-collar implant, horizontal guided bone regeneration and transmucosal healing. Baseline was defined as 7 to 14 days after delivery of the final prosthetic restoration and follow-up was performed after at least 3 years. The primary outcome was change in marginal bone level. Secondary outcomes included probing depth, bleeding on probing, plaque control record, keratinised tissue, midfacial recession and Pink Esthetic Score. Non-parametric tests were applied. Results: Twenty patients (12 men, 8 women) were included, with a mean follow-up period of 42.0 +/- 5.2 months. Mean marginal bone level was 1.06 +/- 0.55 mm at baseline and 1.10 +/- 0.52 mm at follow-up (change in marginal bone level-0.08 +/- 1.02 mm). Fifty percent of implants showed no bone loss or slight gain, 45% < 1 mm loss and 5% between 1.0 and 1.5 mm; no implants showed loss >= 1.5 mm. Probing depth, bleeding on probing, keratinised tissue and midfacial recession remained unchanged (P> 0.05), while plaque control record increased (P = 0.013). Pink Esthetic Score improved from 10.40 +/- 1.79 to 11.90 +/- 1.80 (P < 0.001). Implant survival rate was 100%. Peri-implant health was observed in 85% of cases and mucositis in 15%, with no peri-implantitis. Conclusion: Simultaneous horizontal guided bone regeneration with transmucosal healing around polished-collar implants resulted in stable marginal bone levels and favourable clinical and aesthetic outcomes after 3 years of loading.
PURPOSE:To assess the precision, patient satisfaction and efficiency achieved with three complete-arch implant impression techniques: intraoral scanning, dental photogrammetry and conventional plaster impressions. MATERIALS AND METHODS:Twenty participants with a completely edentulous maxilla or mandible rehabilitated with four to eight implants were included in the study. Each participant underwent six impressions: two using an intraoral scanner, two using a photogrammetry system and two using the conventional open-tray plaster technique. The precision of each impression method was assessed in terms of positioning and angular errors, specifically by the residual mean square and global deflection error. For each of these parameters, impression techniques were compared with a non-parametric Friedman test. Patient satisfaction was evaluated on a visual analogue scale across six domains, and the total time taken for the impression was recorded for each technique. RESULTS:Dental photogrammetry demonstrated the greatest overall precision, with the lowest root mean square error (0.030 ± 0.014 mm) compared to intraoral scanning (0.117 ± 0.068 mm) and plaster (0.110 ± 0.045 mm) (P 0.0001) and the lowest global deflection error (0.349 ± 0.499 degrees) compared to intraoral scanning (1.140 ± 0.556 degrees) and plaster (0.901 ± 0.643 degrees) (P 0.0001). Patient satisfaction was higher for the two digital techniques than for the conventional method. Intraoral scanning was the fastest technique, whereas plaster impressions and photogrammetry required more chair time. CONCLUSIONS:Photogrammetry offers superior precision and favourable patient acceptance for complete-arch implant impressions compared to intraoral scanning and conventional methods. Although intraoral scanning is the fastest method, its precision remains lower in edentulous patients. Photogrammetry could be a valuable alternative in digital workflows for complete-arch impressions. CONFLICT-OF-INTEREST STATEMENT:The authors declare there are no conflicts of interest relating to this study.