
The purpose of this study is to design and control a thick shape memory alloys (SMA) actuator to achieve fast position control with two connected SMA wires. In the past, research had focused on position and force control of thin SMA wires, because they can be cooled fast in air and as it is easy to obtain fast response speeds for SMA actuators in this manner. However, the cooling time increases for thick SMA wires, making it difficult to obtain fast position responses. Phase resistance feedback control (PRFC) minimizes cooling time by shortening the long latency time of thick SMA wires. Compared with binary control, experimental results here show that a rate increase of 18% is achieved using this new method. A new displacement-resistance model which normalizes both resistance and displacement is used to estimate the total output displacement of this new SMA actuator.
New measuring and training method of muscle power for senior age, that utilizes small 'electric generator' instead of conventional 'spring force', is described in this paper. Our study clarified that this method can measure not only the muscle power, but also the reflection time and the muscle strength without any physical stress on aged senior subject. Meanwhile, another advantage of employing electric generator is that generator can electrically produce regeneration resistance as the load for rehabilitation. This paper also describes whether the developed system can be applied for rehabilitation. With a view of physiotherapist, various investigations were executed. The evidences show the effects of the developed training method and the developed system.
A force redistribution method for compensating actuator breakdown of vibration-isolation tables is studied. The vibration-isolation table is supported by eight pneumatic actuators and has a redundant number of actuators with respect to the degrees of freedom of table motion. We propose a force redistribution method that utilizes the redundancy of the actuators. In the proposed method, when some of the actuators break down, their output forces are redistributed on the unbroken actuators. We construct a detailed mathematical model in view of the behavior of the vibration-isolation table when some of the actuators break down. A type 1 digital servo system is applied to control the vibration and position of the vibration-isolation table. We perform numerical simulations in which some of the actuators break down at a certain time and the pressure of the broken actuators decreases at a constant rate. The numerical simulations examine the effectiveness of the proposed method.
In the present study, a target level setting method for the reference signal of operational TPA was considered using the principal component regression method. A principal component having a high contribution to the response signal was selected and target levels of the reference signals were set through principal component sensitivity analysis. In addition, a method that can extract the behavior of a principal component having a high contribution to the response signal was considered for the countermeasure. In order to verify the effectiveness of these methods, operational TPA and the proposed methods were applied to a small model vehicle. In the experiment, floor vibration was set as the response signal and nine measurement points, such as motor attachment points, were used as the reference signals. Here, we set the target reduction level of the response point vibration as 5 dB. Next, the target levels of the reference signal were calculated by principal component sensitive analysis and the countermeasure was considered through the principal component behavior analysis. By referring to the analytical result, a countermeasure to reduce the floor vibration was sought. As a result, the floor vibration level was almost reduced to the target level (5 dB). These considerations and experiments indicate that operational TPA could have additional functionality, whereby the method could set reference signal targets and suggest countermeasure guidelines in addition to performing contribution separation.
This paper presents a method for comparing the input powers and contribution rates from a power source to a structure in machine operation determined by statistical energy analysis (SEA) and transfer path analysis (TPA). Identifying external forces and contribution rates from input power sources during machine operation is important for analyzing machine and equipment, and dynamic designs. SEA is used for systems with many resonant modes, and predicted results are based on spatial averages. In contrast, TPA is based on estimation of a frequency response function between an excitation point and a response point. In this study, a method is proposed for comparing SEA evaluated by the power injection method and TPA evaluated by the matrix inversion method. The proposed method is validated through numerical analyses, using a finite element method of a simple structure consisting of two flat plates connected in an L-shaped configuration and a partial car model consisting of four subsystems. As a result, the SEA input power is spatial averaged over each subsystem quantitatively agrees with the TPA input power expressed as the product of the force and velocity at the excitation point. Contribution rates from a power source, the SEA and TPA results are qualitatively similar without having to consider the phase.