The inherent rigidity of metal stents frequently contributes to restenosis, whereas polymer stents suffer from diminished radial support due to force relaxation. Here, we propose an alternative interpretation of these limitations, which indicates that the radial force relaxation observed in polymer stents may not solely represent a disadvantage, but rather plays a critical role in alleviating the chronic irritation commonly associated with metal stents. This relaxation behavior potentially contributes a fundamental mechanism enabling polymer stents to accommodate the dynamic physiological environment more effectively. Accordingly, we conducted a systematic investigation of the radial force relaxation behavior of self-expanding poly(L-lactic acid) (PLLA) braided stents through in vitro static constant strain relaxation experiments, dynamic alternating strain relaxation experiments, and in vivo pilot animal studies. The results show that the radial force of the stent undergoes significant relaxation, which is concomitant with geometric remodeling characterized by diameter shrinkage and length elongation. This dynamic mechanical evolution underscores the stent’s enhanced adaptability to the lumen. Based on these findings, we propose a conceptual mechanical evaluation framework and a performance evolution curve that integrate the time dimension with dynamic functional evolution. Collectively, this work provides a preliminary theoretical and methodological perspective to guide the development of next-generation polymer stent technologies, notwithstanding the need for further large-scale validation and precise kinetic calibration.
Environmental vibrations induced by metro trains can affect nearby residents, historic buildings, and precision instruments. Installing vibration isolation barriers along propagation paths is a practical mitigation measure for existing metro lines. However, most existing studies used static or fixed-frequency harmonic loading, leaving the performance under moving train loads in layered ground insufficiently understood. This study combines full-scale in situ testing with 3D numerical simulations to investigate the vibration isolation performance of a single-row pile barrier under moving train loads along an at-grade metro line. A coupled layered ground-pile barrier model was established and validated using field measurements, and the effects of pile length, ground condition, and train speed were examined. The barrier significantly reduces vibration within 20–80 Hz, reaching approximately 20 dB at 25 Hz at a point 1 m from the pile axis. In layered ground, its performance is governed by whether the pile toe penetrates the soft-soil waveguide layer. When the pile toe extends into the underlying stiff layer, the piles and the stiff layer form a composite wave-impeding barrier, markedly improving far-field mitigation within 50–80 Hz. Increasing the train speed from 30 to 120 km/h amplifies the ground vibration response but has little effect on the barrier isolation performance. These findings clarify the isolation mechanism in layered ground and guide the design of single-row pile barriers near vibration-sensitive metro areas.
柔性电子以柔性材料、 可变形结构和集成化信号处理为基础, 能够在曲面、 运动以及复杂环境中实现感知与信息交互。 近年来, 柔性电子在可穿戴健康监测、 人机交互、 软体机器人和智能制造等领域发展迅速, 并且逐步从单一器件性能优化拓展到材料、 结构、 传感机制、 算法和系统应用的协同设计。 本专辑收集了本领域具有代表性的研究成果, 介绍了柔性水下机器人、 离子电子压力传感器、 可调应变传感器、 柔性磁力传感器、 激光诱导石墨烯脉搏传感阵列以及温湿度解耦传感器等方面的研究进展, 展示了柔性电子在高灵敏感知、 信号解耦、 稳定封装、 智能识别和软体系统控制中的应用潜力。 希望本期内容能够帮助读者了解柔性电子领域的研究趋势, 推动柔性器件与人工智能、 软体机器人及智能健康技术的进一步融合, 为柔性电子系统的可靠化、 集成化和工程化发展提供参考。
Predicting parameterized flows with moving boundaries requires a compact representation that preserves changes in both geometry and wake dynamics. We develop a nonlinear reduced-order model combining a motion-parameter-conditioned β-variational autoencoder (β-VAE) with latent-space temporal prediction. A separate branch multiplicatively modulates the encoder mean and standard deviation. The posterior mean defines the state advanced by transformers using easy attention or self-attention and by a long short-term memory (LSTM) network. The framework is evaluated on 2D oscillating-cylinder and flapping-airfoil flows. Three and four latent coordinates, respectively, provide compact vorticity reconstructions. In the predefined extrapolation cases, the mean deterministic reconstruction scores are 91.88
Robotic colonoscopy may reduce patient discomfort and operator dependence, but reliable steering remains challenging because intraluminal images contain specular reflections, ambiguous lumen boundaries, occlusion, and anatomy-dependent appearance changes. This paper presents an interpretable low-level vision-guided steering framework that links lumen perception, an explicit image-plane geometric target, and error-dependent gain-scheduled visual servoing. A recurrent residual U-Net trained with segment anything model (SAM)-generated pseudo masks produces a lumen probability map, while an additional confidence head predicts a frame-level segmentation-confidence score. A probability-weighted centroid and five-frame median filter form the visual target, and a reliability gate prevents low-confidence or temporally inconsistent targets from propagating to the controller. When perception is reliable, an error-dependent gain-scheduled proportional–integral–derivative (PID) controller generates yaw and pitch commands to reduce centroid-to-image-center error; otherwise, forward insertion is suspended and the system transitions through temporarily unreliable and recovery states. The framework was evaluated in a collision-free kinematic simulator and a silicone colon phantom as controlled proof-of-concept environments. The segmentation model achieved an inference speed of 30 frames per second with a validation Dice score of 0.92. The mean tracking errors for manual control and the proposed controller were 0.154 and 0.013 cm in a representative Model 1 trial, and 0.0736 and 0.0154 cm across matched simulation trials, respectively. Across three paired phantom trials, the mean image-space error decreased from 201.17 to 136.84 px. These results support the feasibility of an explicit perception–geometry–control architecture for low-level lumen-centered steering.