• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    Nuklearmedizin-nuclear Medicine

    Nuklearmedizin-nuclear Medicine

    Journal中科院 医学 4区

    年发文量

    研究主题

    论文(1480)

    排序
    1Quantitative Reconstructions for Renal Sestamibi SPECT/CT: A Modeled Comparison of 360-Degree Versus 180-Degree Acquisitions.
    Jorge D Oldan,Jennifer A Schroeder, Mathurika Jeyasingam,Lilja B Solnes, Emi Lou Mondragon,Thad Benefield,Mohammad E Allaf,Mark Tulchinsky,Michael A Gorin,Yong Du, Steven P Rowe

    Rationale:99m Tc-sestamibi single-photon emission computed tomography/computed tomography (SPECT/CT) is a cost-effective and accurate means of characterizing indeterminate renal masses. This is scant literature on 99m Tc-sestamibi protocol optimization. Methods:We investigated the difference between modeled, quantitative 180-degree and 360-degree acquisitions for 99mTc-sestamibi SPECT/CT in a cohort of 50 patients who were prospectively enrolled on a scan-and-resect protocol. Two experienced, dual-boarded observers rated each renal mass for image quality (1-5 scale) and diagnosis (benign to malignant, 1-5 scale) in a blinded, randomized order. Ordinal logistic regression was used, incorporating random intercepts for patient and reader; inter-observer variability was assessed. Results:Image quality ratings were significantly higher for 360-degree acquisitions versus 180-degree (P<0.0001; odds ratio 0.22, 95% CI 0.12-0.39). The odds ratio was 0.22 (95% CI: 0.12, 0.39). There was insufficient evidence that the modeled angle of acquisition was associated with scan positivity (P=0.17). The odds ratio was 0.67 (95% CI: 0.37, 1.19). Diagnostic positivity ratings did not differ between reconstruction angles (P=0.17; odds ratio 0.67, 95% CI 0.37-1.19). Conclusions:Modeled 180-degree reconstructions of quantitative SPECT/CT are qualitatively inferior to quantitative reconstructions of 360-degree acquisitions, although there was no difference in the diagnostic accuracy between the reconstruction methods. These results suggest that 180-degree acquisitions are adequate for diagnosis.

    2026
    引用
    AI阅读
    加入学术空间
    2German Society of Nuclear Medicine Procedure Guideline for Dopamine Transporter SPECT Using [123i]ioflupane (02/2026).
    Ralph Buchert,Nathalie L Albert,Henryk Barthel,Henning Boecker, Caroline Bouter,Matthias Brendel,Joachim Brumberg,Alexander Drzezga,Gerhard Gründer,Swen Hesse,Christian la Fougère,Catharina Lange,

    Summary:This procedure guideline for SPECT examinations of striatal dopamine transporter availability is intended to support the planning, execution, quality control, interpretation and reporting of cerebral SPECT scans with [123I]ioflupane. It is an update and expansion built on the 2019 version of the procedure guideline. It was developed through an informal process as a consensus of the Neuroimaging Working Group of the German Society of Nuclear Medicine and in consultation with the German Neurological Society. It is intended for use by physicians and technical staff working in the field of nuclear medicine.

    2026
    引用
    AI阅读
    加入学术空间
    3FDG-PET/CT in Children with Malignant Diseases - Comparison of a Long Axial Field of View Scanner with a Standard Scanner.
    Wolfram A Bosbach, Valentin Manser, Carola M Bregenzer, Nasir Gözlügöl, Korbinian Krieger,Konstantinos Zeimpekis, Angela Filipa Silva Mendes,Swantje Engelbrecht, Angelo R Felgosa Cardoso,Kuangyu Shi,Axel Rominger,Hasan Sari,

    Aim:[18F]FDG positron-emission-tomography/computed tomography (PET/CT) is a crucial tool in paediatric oncology for staging, treatment response assessment, and follow-up imaging. Long axial field of view (LAFOV) PET/CT is more sensitive for the detection of annihilation events than short axial field of view (SAFOV) instrumentation, thus enabling lower radiation dose and/or briefer acquisition time. In consideration of the radiation sensitivity of children, we compared the performance of LAFOV and SAFOV PET/CT in paediatric oncology. Methods:Twenty-six paediatric oncology patients (mean age 13.7 ± 4.8 y), of whom half had diagnosis of lymphoma, underwent 37 [18F]FDG PET/CT scans (12 SAFOV, 25 LAFOV). The LAFOV acquisitions (1-3 MBq/kg) were numerically rescaled to simulate 0.5-3 MBq/kg, yielding 75 LAFOV studies. Four blinded readers rated image quality on a 5-point Likert scale, and recorded various imaging metrics, statistical comparison, and power calculations. Results:LAFOV at 2 and 3 MBq/kg achieved significantly higher Likert ratings than SAFOV. LAFOV at 1 MBq/kg yielded comparable ratings to SAFOV (p=0.13), while 0.5 MBq/kg was inferior to SAFOV (p=0.012). Hepatic background SD decreased and SNR increased dose-dependently with LAFOV (p<0.001), whereas lesion SUVmax and SUVmean remained stable across scanners. TBR was lower for LAFOV at higher doses, despite unchanged image quality. Inter-rater agreement was fair to moderate. Conclusion:LAFOV PET/CT supports [18F]FDG dose reduction without impairing image quality for lesion detection. 1 MBq/kg yielded diagnostic quality comparable to SAFOV, while 2-3 MBq/kg provided superior performance. These results support LAFOV PET/CT as a strategy to minimize radiation exposure in children.

    2026
    引用
    AI阅读
    加入学术空间
    4A Translational Journey in Germany: from Literature to Local Implementation of [ 89 Zr]Zr-DFO-trastuzumab
    Joana do Mar Ferreira Machado,Kristof Zarschler,Torsten Knieß,Martin Kreller, Matthias Miederer, Florian Brandt, Rudi Apolle, Theresa Link, Robert Winzer, Pauline Wimberger, Klaus Kopka, Oliver Kiß

    Aim:[⁸⁹Zr]Zr-DFO-trastuzumab has emerged as a powerful tool to visualise non-invasively HER2 expression across metastatic lesions, complementing conventional pathological HER2 evaluation and helping to identify patients unlikely to benefit from therapy with trastuzumab-based therapies. This paper outlines the roadmap of the manufacturing implementation of [89Zr]Zr-DFO-trastuzumab at our centre in Germany. Methods:In this paper, we describe the key questions encountered during implementation of the manufacturing process for [89Zr]Zr-DFO-trastuzumab and how these were addressed through discussions between academia, hospital departments, teams experienced in the radiolabelling of antibodies and regulatory authorities. Results:Discussions with multiple institutions were essential for the implementation of the GMP-compliant radiosynthesis of [⁸⁹Zr]Zr-DFO-trastuzumab at our manufacturing site. Example decisions included shortening the shelf-life of [⁸⁹Zr]Zr-DFO-trastuzumab to 24 hours to mitigate container-closure integrity concerns and adoption of a bead-based method to determine the immunoreactive fraction. Conclusion:This work presents a practical overview of operational considerations relevant to the clinical implementation of [⁸⁹Zr]Zr-DFO-trastuzumab, with potential applicability to other ⁸⁹Zr-labelled high-molecular-weight radiotracers in Germany. By sharing these practical insights, we aim to support broader patient access to established radiopharmaceuticals and encourage dialogue around open regulatory and practical questions, particularly in anticipation of future clinical trials.

    2026
    引用
    AI阅读
    加入学术空间
    5German Society of Nuclear Medicine Procedure Guideline for Brain Perfusion SPECT Using 99Mtc-Labelled Radiopharmaceuticals (09/2025).
    Ralph Buchert,Philipp T Meyer,Nathalie L Albert,Henryk Barthel,Henning Boecker, Caroline Bouter,Matthias Brendel,Joachim Brumberg, Heinz Hubert Coenen,Alexander Drzezga,Gerhard Gründer,Frank Grünwald,

    Abstract:This procedure guideline for brain perfusion SPECT is intended to support the planning, execution, quality control, evaluation and reporting of brain perfusion SPECT studies using the 99 mTc-labelled radiopharmaceuticals [99 mTc]Tc-HMPAO and [99 mTc]Tc-ECD. It is an update and expansion built on the 2019 version of the procedure guideline. It was developed through an informal process as a consensus of the Neuroimaging Working Group of the German Society of Nuclear Medicine. It is intended for use by physicians and physical-technical staff (technologists, physicists) working in nuclear medicine.

    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 1480 篇论文

    高被引作者

    作者引用发文
    Markus Dietlein161365
    Harald Schicha142862
    O Schober94434
    Christoph Reiners87529
    J. Kotzerke73349
    Wolfgang Eschner66317
    Matthias Schmidt61935
    B Leisner4887
    S. N. Reske43814
    F. Gruenwald42517

    高产作者

    作者引用发文
    Markus Dietlein161365
    Harald Schicha142862
    J. Kotzerke73349
    Matthias Schmidt61935
    O Schober94434
    Felix Mottaghy31334
    Torsten Kuwert39229
    Christoph Reiners87529
    Martin Freesmeyer27328
    Markus Luster24227

    相关期刊

    Nuklearmedizin. Nuclear medicine
    Nuclear medicine review. Central & Eastern Europe
    The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) and the International Association of Radiopharmacology (IAR), and Section of the Society of...
    World journal of nuclear medicine
    Asia Oceania journal of nuclear medicine & biology
    Molecular Imaging and Radionuclide Therapy
    Iranian Journal of Nuclear Medicine
    Médecine Nucléaire
    Der Nuklearmediziner
    Revista Española de Medicina Nuclear e Imagen Molecular (English Edition)