
Objective: Recreational noise exposure is a common preventable cause of hearing loss, yet most evidence on hearing protection behaviors and noise risk perception in music venues comes from surveys conducted away from the listening environment, limiting insight into how patrons perceive and respond to real-time noise exposure. This study assessed hearing protection behaviors and perceptions among patrons actively exposed to high sound levels and piloted an educational tool designed to address patrons’ ability to recognize hazardous noise levels in a music district. Study Design: Cross-sectional survey. Setting: Live music entertainment district. Patients: Adult patrons. Intervention: Participants estimated noise levels before and after exposure to a decibel chart educational tool. Main Outcome Measure: Accuracy of participant-estimated sound levels compared with measured sound levels. Secondary outcomes included hearing protection use, self-reported hearing symptoms, and acceptance of free earplugs. Results: The median measured noise level was 95.0 dBA Leq (IQR: 91.3–97.0). Before education, participants underestimated sound levels by a median of 14.5 dBA Leq (IQR: –80.0 to 5.75; P = 0.030). After education, there was no significant difference between estimated and measured noise levels. Most participants (62.9%) reported postexposure hearing symptoms, and 74.3% never used hearing protection. The free earplug acceptance rate was 42.9%, and no variables independently predicted earplug acceptance. Conclusion: Noise levels exceeded recommended limits. Most participants underestimated sound levels and reported never using earplugs. A decibel chart tool improved estimation accuracy. On-site decibel feedback and free earplugs may promote hearing health practices in music settings.
Objective: To compare patient and provider experiences and opinions regarding auditory training in adult cochlear implant (CI) recipients. Study Design: Narrative review and comparison of patient and provider surveys. Setting: Tertiary referral center and email distribution list of the American Cochlear Implant Alliance. Participants: CI recipients and care providers. Interventions/Methods: We examined and performed a narrative review of two independently developed and published surveys looking at auditory training practices and habits from the perspectives of CI recipients and CI providers, respectively. Main Outcome Measure: Comparison of overlapping topics between patient and provider reports on their experiences with respect to auditory training for CI recipients. Results: Topics for comparison included how auditory training was performed, the timing or logistics of training, and barriers to utilization of training. Findings revealed that auditory training is considered a valuable resource by both CI patients and providers, with similar reports from the 2 groups on the use, timing, and perceived benefits of auditory training. However, we also noted discrepancies between patients and providers with regard to the use of specific types of training and concerns regarding reimbursement for auditory training services. Conclusion: Both CI patients and providers consider auditory training a useful and affordable resource to maximize CI outcomes. However, utilization remains inconsistent. Further study and effort are needed to address key knowledge gaps and better standardize this aspect of peri-CI care.
Objective: Examine the effects of age-at-implant and cognition on receptive language trajectories (RLTs) and expressive language trajectories (ELTs). Study Design: Retrospective cohort study. Analysis of language in children who received their first cochlear implants (CIs) before 2 years of age. Each child completed at least 2 receptive and/or 2 expressive language assessments at least 6 months apart; individual RLTs (n = 403) and ELTs (n = 364) were derived. Pearson correlation and ANOVA were used to analyze RLT/ELT across 4 age-at-implant groups: Group 1 first CI before 9 months; Group 2 CI from 9 to 12 months; Group 3 CI from 12 to 18 months; and Group 4 CI from 18 to 24 months. Cognition, sex, implant configuration, relative socioeconomic advantage, and language background were evaluated. Results: Mean RLT for Groups 1−4 were 1.02 (SD, 0.42; n = 52), 0.86 (SD, 0.36; n = 100), 0.74 (SD, 0.42; n = 140), and 0.75 (SD, 0.38; n = 111), respectively, where 1.0 represents typical language growth over 1 calendar year. Mean ELT for groups 1−4 were 0.87 (SD, 0.41; n = 51), 0.75 (SD, 0.39; n = 99), 0.68 (SD, 0.45; n = 128), and 0.67 (SD, 0.40; n = 86), respectively. There was a significant negative association between age-at-implant and RLT (r = −0.21; P < 0.001) and ELT (r = −0.14; P = 0.007). Cognition was associated with language outcomes, but other child/family variables were not. Conclusions: Cochlear implantation before 9 months of age was associated with age-appropriate language development in children with no cognitive delay. Findings strengthen current arguments for implantation before 9 months.
Objective: To determine the sensitivity and specificity of ambient pressure tympanometry (APT) for the detection of a radiologic correlate of subjective pulsatile tinnitus (PT) Study Design: Retrospective review. Setting: Tertiary care clinic. Patients: 107 adults (147 ears) with PT who underwent APT between 2021 and 2025. Interventions: Blinded audiologists classified APT tracings as pulse-synchronous or not. Main Outcome Measures: Sensitivity and specificity of APT using any radiologic diagnosis or surgeon-defined diagnosis as 2 separate gold standards. Results: Of 137 (93.2%) ears that underwent imaging, 63 (46%) had a pulse-synchronous APT pattern. Fifty-one (37.2%) had a radiologic correlate, and 65 (44.2%) were given a surgeon diagnosis. Respectively, APT sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 51%, 57%, 41.3%, and 66.2% for a radiologic correlate and were 43.1%, 54.9%, 43.1%, and 54.9% for a surgeon diagnosis. In a subgroup of 86 patients (116 ears) with a chief complaint of PT, APT sensitivity, specificity, PPV, and NPV for a radiologic correlate were 56.9%, 54.2%, 46%, and 55.2%, and for a surgeon diagnosis were 43.6%, 54.1%, 46.2%, and 51.6%. Conclusion: With a low sensitivity and specificity, APT may not be a reliable screening tool for the detection of a radiologic correlate of subjective PT. Clinicians should continue to pursue radiologic evaluation of PT despite a negative APT and counsel patients on the limits of imaging and the potential need for multiple modalities for the detection of subjective PT sources.