• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY

    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY

    JournalISSN 0147-8389eISSN 1540-8159中科院 医学 4区

    年发文量

    研究主题

    论文(16917)

    排序
    1Safety of Bioelectric Impedance Analysis Testing in Pediatric Patients with Cardiac Implantable Electronic Devices
    Allegra J. VanderWilde,Timothy K. Knilans,Wayne A. Mays,Sandra K. Knecht,Adam W. Powell

    ABSTRACT Background Bioelectric impedance analysis (BIA) is a useful clinical tool in pediatric heart disease, but concerns regarding cardiac implanted electronic devices (CIEDs) limit its use. This study's goal was to assess the impact of BIA on CIED settings in pediatric patients. Methods This single‐center cohort study included two groups: a retrospective cohort of patients under 21 years old who had CIED interrogation within 12 months before and after BIA use, and a smaller prospective cohort who had CIED interrogation immediately before and after BIA use. The prospective group also underwent real‐time monitoring for electrical interference during BIA. Exclusion criteria included age, implanted loop recorders, and incomplete data. Analysis used either a paired t ‐test or a Wilcoxon signed‐rank test as appropriate, with p ‐value < 0.05 considered statistically significant. Results The retrospective cohort included 55 patients with 80 total tests. A statistically but not clinically significant difference in lead impedance was observed (513 [456, 627] v 513 [399, 593] ohms, p < 0.0001), though no differences were found in electrogram amplitudes, thresholds, or programmed output. When patients with multiple tests were analyzed, there remained a statistically significant difference in lead impedance (513 [399, 614] v 513 [375, 592] ohms, p = 0.0002) but not in other CIED parameters. In the prospective cohort ( n = 10), no electrical interference was appreciated during BIA, and there were no before‐and‐after differences in CIED sensing amplitudes. No inappropriate shocks or premature device failures occurred. Conclusions BIA was not associated with adverse events or meaningful changes in CIED function in this pediatric cohort.

    2026
    引用
    AI阅读
    加入学术空间
    2Primary Prevention ICD in a Contemporary Underserved Population: Factors Associated with Underutilization and Mortality
    Justin J. Song, Sarah Xu, Ariel Gidon, Carlos Matos, Mohammed Kallash,Samuel J. Apple, Girish Jayant, Rani Marhaba,Jacob Borck, Serena Zhang, Sonya Kalani,Yawen Yuan,

    Abstract Background Registry studies from 2000–2010 demonstrated underutilization of primary prevention ICD therapy. As heart failure therapies have reduced sudden cardiac death, investigators have questioned guidelines derived from trials conducted two decades prior, particularly in non‐ischemic cardiomyopathy (NICM) and elderly subgroups. We characterized contemporary referral determinants, decision‐making processes, and outcomes of primary prevention ICD therapy in a diverse, under‐represented population. Methods In this retrospective single‐center cohort study, we reviewed records of all patients meeting Class I criteria for primary prevention ICD in 2019. Multivariable logistic regression identified factors associated with ICD referral, and time‐varying Cox models compared all‐cause mortality by implantation status through 2022. Results Of 559 eligible patients, 345 (62%) were referred and 227 (41%) underwent implantation. Referral was associated with male gender, care coordination by a cardiologist rather than a generalist, and lower social vulnerability index (SVI) score. No decision‐making rationale was documented for a plurality of non‐referred and non‐implanted patients; documented rationales identified potential intervention targets. ICD implantation was not associated with all‐cause mortality (aHR 0.74, 95% CI 0.49–1.12). In exploratory analyses stratified by cardiomyopathy type, implantation was associated with lower mortality in ischemic cardiomyopathy (aHR 0.51, 95% CI 0.27–0.95) but not in NICM (aHR 1.11, 95% CI 0.63–1.95). Conclusion Many eligible patients are never referred for ICD therapy. Female gender, generalist care coordination, and high SVI were associated with non‐referral. The exploratory association of implantation with lower mortality in ischemic cardiomyopathy was not significant in propensity score overlap‐weighted analyses. The NICM estimate was imprecise.

    2026
    引用
    AI阅读
    加入学术空间
    3Pulsed Field Versus Contact Force Radiofrequency Ablation in Persistent Atrial Fibrillation: A Meta‐Analysis
    ARSH REHMAN,ZhuHua Sun, Muhammad Khalid, HaoZhe Deng, Yuanyuan Chen, Shengli An, Kun Xiang, JianQin Zhang,XinZhong Li, Fahd Mohammed Abdullah Makhsham,SenLin Huang,HaiRuo Lin,

    ABSTRACT Background Atrial fibrillation (AF) remains a challenging arrhythmia to manage, and catheter ablation is a cornerstone therapy. Pulsed Field Ablation (PFA) has recently emerged as a novel non‐thermal alternative to Contact Force Radiofrequency (CF‐RF) ablation. This meta‐analysis compares the efficacy, safety, and procedural efficiency of PFA versus CF‐RF in patients with persistent atrial fibrillation. Methods A systematic review and meta‐analysis were conducted using randomized controlled trials and cohort studies identified from MEDLINE, Embase, and Cochrane databases. Primary outcomes included 12‐month freedom from atrial arrhythmia (AF, atrial flutter, or atrial tachycardia), procedure duration, fluoroscopy time, and major complications. Subgroup analyses were performed based on PFA device type (Farapulse vs. HT‐9000Pro) and patient characteristics, including left atrial size and AF duration. Results Seventeen studies met inclusion criteria. PFA was associated with significantly higher 12‐month freedom from atrial arrhythmia compared with CF‐RF (OR = 1.36, 95% CI 1.26–1.47, p < 0.001). Procedure time was markedly shorter with PFA (MD = −40.5 minutes, p < 0.001), while fluoroscopy time also showed a significant reduction (MD = −1.8 minutes, p = 0.001). Major complications were significantly lower with PFA (1.2% vs. 2.8%; OR = 0.44, 95% CI 0.35–0.57, p < 0.001). Conclusion In persistent AF, PFA, demonstrates superior efficacy, safety, and procedural efficiency compared with CF‐RFA, supporting its role as a potential first‐line ablation strategy. Larger multicenter trials with long‐term follow‐up are needed to confirm durability and device‐specific outcomes.

    2026
    引用
    AI阅读
    加入学术空间
    4Concomitant Aveir AR and Micra AV2 Hybrid Leadless Implantation During Infected Pacemaker Extraction
    Michael Alston, Sri Nuvvula, Catherine Pham, Julie Thomas,James K. Gabriels,Laurence M. Epstein

    ABSTRACT Leadless pacing is an important option for patients with device‐related infections. In those requiring dual‐chamber support, reduced atrial battery longevity due to continuous implant‐to‐implant (i2i) communication remains a concern. While recent software updates now allow for the disablement of i2i communication when clinically appropriate, this mode does not provide atrioventricular synchronous pacing. We describe a case of a hybrid leadless system combining an atrial leadless pacemaker (Aveir AR, Abbott) and a second leadless pacemaker capable of atrial mechanical‐sensed ventricular pacing (Micra AV2, Medtronic) in the setting of extraction of an infected transvenous pacemaker, providing atrial pacing with ventricular backup capability while preserving atrial device longevity.

    2026
    引用
    AI阅读
    加入学术空间
    5Insertable Cardiac Monitoring in Pediatric Patients: A Real‐World Single‐Center Experience with a New‐Generation Device
    Massimo Stefano Silvetti,Ilaria Tamburri,Ilaria Cazzoli,Cristina Raimondo, Daniela Righi,Luigina Porco,Marta Unolt,Fabio Anselmo Saputo,Giacomo Silvetti,Monica Campari,Sergio Valsecchi,Fabrizio Drago

    ABSTRACT Background Insertable cardiac monitors (ICMs) are increasingly used in pediatric patients, yet data on new‐generation devices remain limited. The aim of this retrospective study was to describe a single‐center real‐world experience with a new‐generation ICM in pediatric patients, focusing on procedural feasibility, sensing performance, transmission burden, and user experience. Methods Consecutive patients aged ≤18 years undergoing LUX‐Dx ICM implantation between 2023 and 2025 were included. Procedural characteristics, sensing parameters, transmission patterns, diagnostic yield, reprogramming strategies, and patient/caregiver‐reported experience were analyzed. Data are reported as median (25th–75th percentile) or mean ± standard deviation. Results Twenty‐nine patients underwent ICM implantation. Procedures were brief (6 ± 2 min) and complication‐free. Electrical parameters were satisfactory and stable at discharge. Follow‐up was 18 (6–23) months. A median of 2.7 transmissions per patient‐month were received, of which 55% were alerts. Time from arrhythmia detection to transmission was 15 (3–21) hours. The number of episodes per patient was 4.8 (3.1–15.9) per month, with substantial inter‐patient variability and bradycardia being the most frequent detection (80%). A diagnostic conclusion was reached in 79% of patients (positive: 45%, negative: 34%) at a median of 3 months. Reprogramming was performed in 90% of patients, mainly remotely (77%), and was predominantly directed toward reducing detection sensitivity. Patient and caregiver acceptance of remote monitoring was high. Conclusions In pediatric patients, new‐generation ICM implantation was safe, well tolerated, and associated with stable sensing performance. Remote monitoring and reprogramming enabled timely diagnosis and individualized optimization, supporting the clinical utility of contemporary ICMs in this population.

    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 16917 篇论文

    高被引作者

    作者引用发文
    Seymour Furman3630239
    John Camm3540165
    David L. Hayes312377
    Marek Malik2893103
    Jacques Clementy241748
    Serge Cazeau236427
    Blair P. Grubb2364107
    Harry Mond233935
    George Klein227987
    Bruce Wilkoff224347

    高产作者

    作者引用发文
    Seymour Furman3630239
    S. Serge Barold2160172
    John Camm3540165
    John Devens Fisher2136135
    Blair P. Grubb2364107
    Marek Malik2893103
    Pedro Brugada213091
    George Klein227987
    Kenneth Ellenbogen205279
    Sanjeev Saksena112079

    相关期刊

    The Journal of invasive cardiology
    Journal of atrial fibrillation
    Cardiac electrophysiology clinics
    Arrhythmia & electrophysiology review
    Interventional cardiology (London, England)
    The Journal of innovations in cardiac rhythm management
    Structural heart : the journal of the Heart Team
    JACC. Case reports
    Herzschrittmachertherapie und Elektrophysiologie
    Indian Pacing and Electrophysiology Journal