
Abstract In this work, the determination of uranium in aqueous samples by a liquid scintillation counter is discussed. The method is based on the extraction of uranium with a combined mixture of tributyl phosphate and extractive scintillation cocktail after suitable sample treatment. In this method, two different water-immiscible cocktails, namely, Ultima Gold F (UGF) from Perkin Elmer and Maxilight+ from Hidex, are used. A detection limit of 22 mBq/L and 17 mBq/L for UGF and Maxilight+ was obtained for a counting period of 500 min. Calibration measurements performed with test samples of known activity showed good agreement within the accepted margins.
Abstract A radiation worker today may legally receive over 5 years what a colleague a century ago received in a single week – not because science discovered radiation to be more dangerous, but because it discovered how much more there was to guard against. This article traces that 100-year descent, from the crude “tolerance dose” of ≈ 700 mSv/year set in the 1930s to today’s 20 mSv/year occupational limit, through the four International Commission on Radiological Protection (ICRP) milestones – Publications 26, 60, 103, and 118 – that rewrote the rules as evidence from Hiroshima, Chernobyl, and decades of occupational cohort studies accumulated. It examines why the linear no-threshold (LNT) model, despite persistent challenges from the radiation-hormesis camp, remains the working consensus of the ICRP, International Atomic Energy Agency, World Health Organization, and Biological Effects of Ionizing Radiation VII; clarifies the distinct rules that govern medical and emergency exposures; and looks ahead to the next ICRP system revision, which is likely to bring age- and sex-specific risk coefficients, formal recognition of circulatory disease as a radiation detriment, and artificial intelligence-assisted dosimetry – changes that will, in time, filter down through Atomic Energy Regulatory Board regulation to every badge-wearing radiation worker in India. The message for practitioners is direct: dose limits are not numbers fixed once and for all; they are a living record of what the radiation protection community has learned and is still learning about keeping people safe.
Abstract The International Commission on Radiological Protection (ICRP) developed adult mesh-type reference computational phantoms (MRCPs) in ICRP Publication 145, 2020, to address the geometric constraints of conventional voxel phantoms, especially in representing thin tissues and fine anatomical details. These MRCPs will be used for future dosimetric calculations and adopted as a basis for the upcoming general recommendations. Hence, the Publication 145 recalculated the reference dose coefficients (DCs) for external exposure using PHITS, MCNP and Geant4 Monte Carlo codes. In the present study, DC values for photon energies ranging from 0.05 to 20 MeV under anteroposterior and isotropic irradiation conditions were calculated using the recently released updated version of the FLUKA Monte Carlo code (v. 4.5.0 onwards). In this version of FLUKA, the adult male and female MRCP data provided in ICRP Publication 145 were implemented using the UMESH framework, which is compatible with mesh-type geometries. In addition, DC values were independently evaluated using the Geant4 code, and results from both transport codes were benchmarked against the reference values reported in ICRP Publication 116, which were simulated using voxel phantoms. The observed agreement confirms the correct implementation of MRCPs in both transport codes (FLUKA and Geant4) and demonstrates their applicability for further dosimetric applications.
Abstract Radon ( 222 Rn) in groundwater poses significant public health risks due to its radiological impact when ingested or inhaled. In this study, radon concentrations in drinking water sources were assessed using the RAD7 radon detector, with the aim of evaluating associated ingestion doses. A total of 20 water samples were analyzed from various hand-dug wells and boreholes in Alimosho area, Lagos State. The measured radon concentrations ranged from 1.60–11.50 Bq/L, with a mean value of 7.02 Bq/L. Corresponding ingestion doses varied between 4.08 and 29.38 µSvy − 1 , with an average of 17.78 µSvy − 1 . Although these values remain within the recommended safe limits prescribed by the World Health Organization and the United States Environmental Protection Agency, localized elevated concentrations were observed in some borehole samples. A comparative analysis with previous studies across Nigeria revealed that the results from this study are higher than those in Ogbomosho (1.86 Bq/L) but lower than values reported in Iwaraja (45.80 Bq/L) and Katsina (46.80 Bq/L). The observed variations in radon levels across regions are linked to differences in underlying geological formations, hydrogeological properties, and anthropogenic activities such as mining and quarrying. The findings suggest that while the overall risk remains low, continuous monitoring and localized assessments are essential to identify potential hotspots and guide public health interventions.