Vancomycin-resistant Enterococcus (VRE) infections are classified as a Category V infectious disease under the Infectious Diseases Control Law. The reporting criteria are VCM MIC ≧16 µg/mL, and the presence of van is not included, but vanA/B are important resistance genes for infection control. Since some VRE strains with van genes have low VCM MIC, screening medium are useful for detection; however, culture time varies depending on the medium, and the content of VCM and selective agents is not clear. In this study, we evaluated the optimal culture time for CHROMagar VRE blue medium (CH-blue, Kanto Chemical) and BD BBL VRE medium (BD-VRE, BD Japan). A total of 29 strains were tested, including 24 Enterococcus faecium strain with vanA/B/D (VCM MIC 8->16 µg/mL) and one Enterococcus faecalis strain with the vanA (VCM MIC 8 µg/mL) detected in our hospital, and 4 standard strains. According to the Misra method, each medium was inoculated with 106-10 cfu/spot. Cultures were incubated at 35°C under aerobic conditions for 72 hours, with growth checked every 24 hours. CH-blue showed no concentration with a 100% detection rate in the specified 24-hour incubation, whereas BD-VRE showed a 100% detection rate only at 106 cfu/spot in the specified 48-hour incubation. Both media showed a 100% detection rate at 106 and 105 cfu/spot in the 72-hour incubation. The detection sensitivity was improved with a 72-hour incubation for both media, potentially reducing the risk of missing VRE in routine examinations.
Background: Campylobacter fetus subsp. fetus is a Gram-negative spiral-shaped rod commonly colonizing livestock such as cattle and sheep. In humans, it can cause bacteremia, meningitis, and infective endocarditis, particularly in immunocompromised hosts. Herein, we describe a sporadic case of necrotizing fasciitis caused by Campylobacter fetus subsp. fetus. Case presentation: We report a case of necrotizing fasciitis caused by C. fetus subsp. fetus in an older woman in her 80s undergoing maintenance hemodialysis. The patient initially presented with left thigh pain without remarkable findings and was discharged with symptomatic treatment. Three days later, she developed fatigue and was admitted. On hospital day 5, a Gram-negative spiral-shaped bacillus was isolated from blood cultures, and the same organism was subsequently recovered from necrotic fascia tissue of the left thigh, establishing the diagnosis of necrotizing fasciitis caused by C. fetus subsp. fetus. Conclusion: Although early identification was challenging, clinical background, Gram stain findings, and colony morphology facilitated presumptive identification, enabling the timely initiation of appropriate antimicrobial therapy. This case highlights the importance of considering C. fetus subsp. fetus in rare presentations of necrotizing fasciitis.
BacT/ALERT VIRTUO is the first fully automated blood culture analysis system that provides complete automation of bottle loading, registration, and retrieval. In April 2017, we changed the blood culture device from BacT/ALERT 3D to BacT/ALERT VIRTUO and the blood culture bottles from SA·SN culture bottles to FA·FN Plus culture bottles, and examined the detection status of anaerobic bacteria before and after the introduction of BacT/ALERT VIRTUO. The target period was set at five years for each of the 3D usage period (2012 to 2016) and VIRTUO usage period (2017 to 2021). The overall positive rate of blood cultures was 11% for 3D and 15% for VIRTUO, and the positive rate of anaerobic bacteria was 0.77% for 3D and 1.15% for VIRTUO, showing a significant increase after the introduction of VIRTUO. In addition, the median detection time for all anaerobic bacteria was 52.8 hours with 3D and 38.4 hours with VIRTUO, indicating a reduction of 14.4 hours with VIRTUO, enabling early detection of bacteria after the introduction of VIRTUO. By switching to VIRTUO and FA/FN Plus culture bottles, the positive rate for anaerobic bacteria improved and detection times were also shortened. Rapid and accurate detection of bacteria from blood cultures is important for the appropriate use of antibiotics, and BacT/ALERT VIRTUO is a useful tool fou this purpose.
For Clostridioides difficile infections, highly sensitive rapid diagnostic test kits are necessary for prompt diagnose and infection control. In this study, we evaluated "Quick Chaser CD GDH/TOX" (evaluation kit), a rapid diagnostic kit for C. difficile, using 65 clinical stool specimens, comparing with GE test immunochromato-CD GDH/TOX "Nissui" (GE test) and TECHLAB C. DIFF QUIK CHEK COMPLETE (QUIK CHEK). The results of the evaluation kit showed a high concordance rate; 100% the positive concordance rate (31/31) and 97.1% the negative concordance rate (33/34) of GDH, 94.1% the positive concordance rate (16/17) and 97.9% the negative concordance rate (47/48) of toxin against GE test, respectively. Also 96.9% the positive concordance rate (31/32) and 97.0% the negative concordance rate (32/33) of GDH, 100% the positive concordance rate (12/12) and 90.6% the negative concordance rate (48/53) of toxin against QUIK CHEK, respectively. Additionally, comparison of discrepancy cases between kits based on Nucleic Acid Amplification test, one false negative each for GDH and toxin in the evaluation kit, two false negatives for GDH and one false negative for toxin in the GE test, one false negative for GDH and six false negatives for toxin in QUIK CHEK, and no false positive cases were observed. Therefore, the detection sensitivity of GDH and toxin of the evaluation kit was equivalent to that of two types of comparative kits.
Bacteremia can easily become severe, and it is necessary to start appropriate treatment quickly before it progresses to sepsis. In this study, we investigated a method using antibiotic discs to quickly report antibiotic resistance information for bacteremia caused by gramnegative bacilli, such as Enterobacterales, which require careful selection of appropriate antibiotics due to their tendency to cause severe illness. In cases of bacteremia caused by ESBL and AmpC-producing bacteria, reports of suspected antibiotic resistance mechanisms were made within a few hours after disk placement, allowing for the rapid modification of antimicrobial therapy, thereby contributing to the treatment. This method is considered highly beneficial as it does not require special equipment and is a cost-effective approach. However, as this method is different from the conventional disk diffusion method, and since some cases showed susceptible inhibition zone diameters for antibiotics considered to have intrinsic resistance, further investigation is necessary for its use in determining susceptibility.