• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    Sichuan Electric Power Technology

    Sichuan Electric Power Technology

    JournalISSN 1003-6954

    年发文量

    研究主题

    论文(3042)

    排序
    1Review on Charge Generation, Measurement and Dissipation in Large-length HVDC Cable
    ,,,,

    Carbon emission reduction, as one of the core drivers of energy transformation, can effectively promote clean energy development and mitigate the global greenhouse effect. In the context of the development of the global energy internet, large-length HVDC cables for long-distance and cross-regional power transmission occupy an essential position in the power internet. However, the accumulation of electric charges in the large-length HVDC cables is inevitable, and would threaten the safe operation of the cables, reduce their service life and might even cause insulation fault. Therefore, it is indispensable to study the electric charges in large-length HVDC cables. This article provides a brief overview of electric charge generation, measurement and dissipation in HVDC cables, and summarizes the important research issues in recent years, which can provide informative guide for both online monitoring and life assessment of large-length HVDC cables.

    2024
    引用
    AI阅读
    加入学术空间
    2Research on Substation Leakage Current Detection Device Based on Wireless Synchronous Communication
    LIU Xin,YUAN Mingzhe, HUANG Yin, LINGHU Jingbo,ZOU Jingxin, LIU Yuhang

    Auxiliary power system of substation is the key to ensure the safe and stable operation of substation,but the leakage current in the cable may cause serious accidents such as channel fire.And the fixed monitoring device has many disadvantages,such as high cost and difficult popularization.Aiming at the problem of accurate detection of leakage current of auxiliary power system,a new leakage current detection system of auxiliary power system is developed.This system is composed of multiple wireless acquisition terminals and has the functions of multi-channel synchronous acquisition,automatic data communication,current vector sum calculation,which can realize the accurate detection of leakage current and the accurate positioning of defects in auxiliary power system,so as to eliminate the potential accidents in time.In order to verify the effectiveness and accuracy of the proposed system,the actual detection is carried out in the substation site,and many potential current leakage problems in auxiliary power system are found and processed.The results show that this system can quickly,effectively and accurately detect the operation of auxiliary power system and is helpful to ensure the safe and stable operation of substation,which has high economy and practicability.

    2024
    引用
    AI阅读
    加入学术空间
    3Analysis of the Unbalanced Current among Paralleled MMCS Caused by Commutation Failures in Hybrid Cascaded UHVDC System
    ,,

    The hybrid cascaded ultra-high voltage direct current (UHVDC) transmission system, which combines the advantages of the line commutated converter (LCC) based and modular multilevel converter (MMC) based UHVDC system, has good engineering prospects. In this topology, the rectifier side adopts LCCs, and the inverter side adopts an LCC connected in series with three paralleled MMCs. In this paper, the mechanism of unbalanced current among the paralleled MMCs induced by commutation failures of LCC is analysed. Firstly, the cause of unbalanced current is explained by combining the control strategy and the change of the inverter equivalent topology after commutation failures. Furthermore, the main factors affecting the unbalanced current are analysed, including the smoothing reactor, the constant current control on the rectifier side and the voltage dependent current order control (VDCOL). Finally, the validity of the mechanism analysis is verified by simulations based on PSCAD/EMTDC platform. The technical route and key points of limiting unbalanced current are also put forward.

    2024
    引用
    AI阅读
    加入学术空间
    4Research on Identification Model of Rainfall Induced Geological Hazard Outbreak for Power Grid in Strong Earthquake Area
    BU Xianghang, LIU Fan,CAO Yongxing, FAN Songhai, CHEN Ling,WU Chi,ZHU Ke,XUE Zhihang

    以汶川地震强震区岷江干流及渔子溪沿岸的 42 个泥石流为研究对象,提取泥石流流域中物源存储量、暴发频率、流域面积等 7 个重要因子,运用CRITIC法建立电网降雨诱发泥石流灾害识别模型,将识别结果划分三级:15 条泥石流流域属于高易发性泥石流灾害;11 条泥石流流域属于中易发性泥石流灾害;16 条泥石流流域属于低易发性泥石流灾害.然后,选取研究区内 26 条泥石流曾经一次冲出物源量来验证电网泥石流灾害识别模型的可行性.最后,通过ARCGIS平台生成电网泥石流灾害易发生分区图.

    2023
    引用
    AI阅读
    加入学术空间
    5Simulation Study on Steady-state Current Carrying Capacity of Intermediate Joints of Directly Buried 110 kV Cables
    CHEN Li,SHAO Qianqiu, WANG Ranran, TANG Jun

    针对目前没有成熟的交流电缆中间接头载流量校核方法,搭建了土壤直埋 110 kV电缆中间接头和电缆本体稳态载流量三维仿真模型,利用有限元对比研究环境温度、土壤导热系数和敷设深度对电缆中间接头和本体稳态载流量的影响规律.结果表明:在不同环境温度、土壤导热系数和敷设深度下,电缆中间接头载流量始终小于电缆本体载流量,土壤导热系数为 0.5 W·(m·K)-1、环境温度为 293 K以及敷设深度为 1.75 m时的中间接头载流量相较于相同条件下的本体载流量减小了 10.8%.因此,如按照电缆本体载流量校核电缆载流能力,将导致中间接头主绝缘处于加速热老化状态.为确保电缆长期稳定运行,建议以本体载流量确定电缆载流时应留有一定裕度.

    2023
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 3042 篇论文

    高被引作者

    作者引用发文
    Junyong Liu19751
    Xingyuan Li14535
    Nian Liu10328
    Xianyong Xiao8435
    Xiqiang Chang7254
    Guorong Zhang591
    Hai Guo591
    Jianhui Su591
    Tianqi Liu4714
    Huan Teng4512

    高产作者

    作者引用发文
    Xiqiang Chang7254
    Junyong Liu19751
    Xianyong Xiao8435
    Xingyuan Li14535
    Nian Liu10328
    yufei teng2226
    Lijie Ding2924
    XiuPing Yao3022
    Xinyan Zhang2816
    Honggeng Yang2014

    相关期刊

    Zhejiang Electric Power
    Power Capacitor & Reactive Power Compensation
    Electric Switchgear
    Qinghai Electric Power
    Electrotechnics Electric
    Hunan Electric Power
    Ningxia Electric Power
    Transformer
    Electrotechnical Application
    Hebei Electric Power