We present design details for drift chambers to be used in the CLAS detector at CEBAF. Novel features include nonparallel endplates fabricated from composite materials, a gas mixture which includes helium to reduce multiple scattering, low wire tension, and a hexagonal cell layout. Magnetic field strength in the active region ranges from 0 to 2 T, and wire length varies from 10 to 300 cm. We discuss specific construction details for the outer drift chambers.