Ionization cooling is the preferred method for producing bright muon beams. This cooling technique requires the operation of normal conducting, radio-frequency (rf) accelerating cavities within the multitesla fields of dc solenoid magnets. Under these conditions, cavities exhibit increased susceptibility to rf breakdown, which can damage cooling channel components and imposes limits on channel length and transmission efficiency. We report, for the first time, stable high-vacuum, normal-conducting cavity operation at gradients of 50 MV/m in an external magnetic field of three tesla, through the use of beryllium cavity elements. This eliminates a significant technical risk that has previously been inherent in ionization cooling channel designs.
Solenoid Siberian snakes have successfully maintained polarization in particle rings below 1 GeV, but never in multi-GeV rings, because the spin rotation by a solenoid is inversely proportional to the beam momentum. High energy rings, such as Brookhaven's 255 GeV Relativistic Heavy Ion Collider (RHIC), use only odd multiples of pairs of transverse B-field Siberian snakes directly opposite each other. When it became impractical to use a pair of Siberian Snakes in Fermilab's 120 GeV/c Main Injector, we searched for a new type of single Siberian snake that could overcome all depolarizing resonances in the 8.9-120 GeV/c range. We found that a snake made of one 4-twist helix and 2 dipoles could maintain the polarization. This snake design could solve the long-standing problem of significant polarization loss during acceleration of polarized protons from a few GeV to tens of GeV, such as in the AGS, before injecting them into multi-hundred GeV rings, such as RHIC.
The international Muon Ionization Cooling Experiment (MICE) will perform a systematic investigation of ionization cooling with muon beams of momentum between 140 and 240 MeV/c at the Rutherford Appleton Laboratory ISIS facility. The measurement of ionization cooling in MICE relies on the selection of a pure sample of muons that traverse the experiment. To make this selection, the MICE Muon Beam is designed to deliver a beam of muons with less than ∼1% contamination. To make the final muon selection, MICE employs a particle-identification (PID) system upstream and downstream of the cooling cell. The PID system includes time-of-flight hodoscopes, threshold-Cherenkov counters and calorimetry. The upper limit for the pion contamination measured in this paper is f_π < 1.4% at 90% C.L., including systematic uncertainties. Therefore, the MICE Muon Beam is able to meet the stringent pion-contamination requirements of the study of ionization cooling.
A muon collider or Higgs factory requires significant reduction of the six dimensional emittance of the beam prior to acceleration. One method to accomplish this involves building a cooling channel using high pressure gas filled radio frequency cavities. The performance of such a cavity when subjected to an intense particle beam must be investigated before this technology can be validated. To this end, a high pressure gas filled radio frequency (rf) test cell was built and placed in a 400 MeV beam line from the Fermilab linac to study the plasma evolution and its effect on the cavity. Hydrogen, deuterium, helium and nitrogen gases were studied. Additionally, sulfur hexafluoride and dry air were used as dopants to aid in the removal of plasma electrons. Measurements were made using a variety of beam intensities, gas pressures, dopant concentrations, and cavity rf electric fields, both with and without a 3 T external solenoidal magnetic field. Energy dissipation per electron-ion pair, electron-ion recombination rates, ion-ion recombination rates, and electron attachment times to $SF_6$ and $O_2$ were measured.
The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires an efficient particle-identification (PID) system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter that forms part of the PID system and tags muons that traverse the cooling channel without decaying. The detector is capable of identifying electrons with an efficiency of 98.6%, providing a purity for the MICE beam that exceeds 99.8%. The EMR also proved to be a powerful tool for the reconstruction of muon momenta in the range 100–280 MeV/c.
A special vacuum vessel prototype was built [1] to house the first electropolished 201-MHz RF cavity for the International Muon Ionization Cooling Experiment (MICE) [2]. The resulting prototype RF module has been assembled, instrumented, installed and commissioned at Fermilab’s MuCool Test Area (MTA) [3] and the effort has provided valuable experience for design and assembly of modules that will be used in the cooling channel for the experiment. MECHANICAL ASSEMBLY AND INSTALLATION
A first electropolished 201-MHz RF cavity for the international Muon Ionization Cooling Experiment (MICE) has been assembled inside a special vacuum vessel and installed at the Fermilab’s MuCool Test Area (MTA). The cavity and the MTA hall have been equipped with numerous instrumentation to characterize cavity operation. The cavity has been commissioned to run at 14 MV/m gradient with no external magnetic field; it is also being commissioned in presence of fringe field of a multiTesla superconducting solenoid magnet, the condition in which cavity modules will be operated in the MICE cooling channel. The assembly, installation and operation of the Single-Cavity Module gave valuable experience for operation of full-sized modules at MICE.
Ionization cooling of intense muon beams requires the operation of high-gradient, normal-conducting RF structures in the presence of strong magnetic fields. We have measured the breakdown rate in several RF cavities operating at several frequencies. Cavities operating within solenoidal magnetic fields B > 0.25 T show an increased RF breakdown rate at lower gradients compared with similar operation when B = 0 T. Ultimately, this breakdown behavior limits the maximum safe operating gradient of the cavity. Beyond ionization cooling, this issue affects the design of photoinjectors and klystrons, among other applications. We have built an 805 MHz pillbox-type RF cavity to serve as an experimental testbed for this phenomenon. This cavity is designed to study the problem of RF breakdown in strong magnetic fields using various cavity materials and surface treatments, and with precise control over sources of systematic error. We present results from tests in which the cavity was run with all copper surfaces in a variety of magnetic fields.
The MuCool Test Area (MTA) at Fermilab is a facility to develop the technology required for ionization cooling for a future Muon Collider and/or Neutrino Factory. As part of this research program, we have tested two 805 MHz vacuum RF cavities in a multi-Tesla magnetic field to study the effects of the static magnetic field on the cavity operation. This study gives useful information on field emitters in the cavity, dark current, surface conditioning, breakdown mechanisms and material properties of the cavity. All these factors determine the maximum accelerating gradient in the cavity. This paper discusses the image processing technique for quantitative estimation of spark damage spot distribution on cavity interior surfaces. The distribution is compared with the electric field distribution predicted by a computer code calculation. The local spark density is proportional to probability of surface breakdown and shows a power law dependence on the maximum electric field (E). This E dependence is consistent with the dark current calculated from the Fowler-Nordheim equation.
Current muon collider schemes call for significant six dimensional (6D) cooling of the muon beam before it is accelerated [1]. One cooling scheme, the Helical Cooling Channel (HCC), employs RF cavities filled with high pressure hydrogen gas [2]. The gas acts both as an energy loss mechanism to allow for ionization cooling [3, 4], and as a buffer in order to prevent RF breakdown [5]. When a beam of particles passes through a HPRF cavity, it will ionize the gas. The amount of plasma generated is dependent on the beam energy, the stopping power of the gas, and the density of the gas. The resulting plasma will gain energy from the RF electric field and transfer it through collisions to the gas. This effect is called plasma loading. An experiment performed at theMuCool Test Area at Fermilab studied the formation of plasma created by a proton beam and its evolution over the course of many 805 MHz RF cycles [6].
A major technological challenge in building a muon cooling channel is operating rf cavities in multitesla external magnetic fields. We report the first proof-of-principle experiment of a high pressure gas-filled rf cavity for use with intense ionizing beams and strong external magnetic fields. rf power consumption by beam-induced plasma is investigated with hydrogen and deuterium gases with pressures between 20 and 100 atm and peak rf gradients between 5 and 50 MV/m. The low pressure case agrees well with an analytical model based on electron and ion mobilities. Varying concentrations of oxygen gas are investigated to remove free electrons from the cavity and reduce the rf power consumption. Measurements of the electron attachment time to oxygen and rate of ion-ion recombination are also made. Additionally, we demonstrate the operation of the gas-filled rf cavity in a solenoidal field of up to 3 T, finding no major magnetic field dependence. All these results indicate that a high pressure gas-filled cavity is a viable technology for muon ionization cooling.
A high pressure hydrogen gas-filled RF (HPRF) cavity can operate in the multi-Tesla magnetic fields required for a muon accelerator cooling channel. A beam test was performed at the Fermilab MuCool Test Area by sending a 400 MeV proton beam through an 805 MHz cavity and quantifying the effects of the resulting plasma within the cavity. The resulting energy loss per electron-ion pair produced has been measured at 10 18 to 10 16 J every RF cycle. Doping the hydrogen gas with oxygen greatly decreases the lifetime of an electron, thereby improving the performance of the HPRF cavity. Electron lifetimes as short as 1 ns have been measured, and electron-ion recombination rates are on the order of 10 6 cm 3 /s. The recombination rate of positive and negative ions in the cavity has been measured on the order of 10 8 cm 3 /s. Extrapolation in both gas pressure and beam intensity are required to obtain Muon Collider parameters, however the results indicate HPRF cavities can be used in a muon accelerator cooling channel.
A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.2–2.3 π mm-rad horizontally and 0.6–1.0 π mm-rad vertically, a horizontal dispersion of 90–190 mm and momentum spreads of about 25 MeV/c. There is reasonable agreement between the measured parameters of the beams and the results of simulations. The beams are found to meet the requirements of MICE.
Filling an RF cavity with a high pressure gas prevents breakdown when the cavity is place in a multi-Tesla external magnetic field. The choice of hydrogen gas provides the additional benefit of cooling a beam of muons. A beam of particles traversing the cavity, be it muons or protons, ionize the gas, creating an electron-ion plasma which absorbs energy from the cavity. The ionization rate can be calculated from a beam intensity measurement. Energy loss measurements indicate the loading per RF cycle per electron-ion pair range from 10 −18 to 10 −16 J in pure hydrogen, and 10 −20 to 10 −18 J when hydrogenis doped with dry air. The addition of an electronegativegas (oxygen)has been observedto reduce the lifetime of ionization electrons in the cavity to below 1 nanosecond. Additionally, the recombination rate of electrons and hydrogen ions has been measured to be on the order of 10 −6 cm 3 /s. The recombination mechanism and hydrogen ion species, along with the three-body attachment process of electrons to oxygen, will be discussed.