Postoperative adhesions occur frequently after abdominal surgery and gynecological surgeries, causing serious complications. For applications in laparoscopic surgery, we developed a thermally cross-linked gelatin film-cut (GC) by dividing a thermally cross-linked gelatin film (GF) into small fragments. In this study, we examined the basic biological properties of the GC and conducted anti-adhesion tests using a rat cecum abrasion model to evaluate the effects of film fragmentation, focusing on the influence of fragment size, dosage and film thickness. Solubility test results showed that GC degraded more slowly than its film counterparts. Furthermore, as the thickness and the size of the GC increased, its degradation rate decreased. In addition, the results of the collagenase degradation test demonstrated that the GC degraded more slowly than the unfragmented film and that as the thickness and size of the GC increased, its degradation rate decreased. The results of the rat anti-adhesion test demonstrated that compared with GF, GC was significantly less effective in preventing adhesion. However, compared with the untreated group, several GCs showed significantly lower adhesion scores. Some of the GCs demonstrated anti-adhesion effect similar to or better than those of hyaluronic acid and carboxymethyl cellulose (HA/CMC). In summary, increased fragment size, reduced film thickness, and an elevated dosage of GC improved anti-adhesion efficacy. Thus, GC exhibits excellent anti-adhesion effects when its geometry, thickness, and dosage are optimized. Consequently, anti-adhesive GC improves the clinical applicability of anti-adhesion materials, particularly in laparoscopic surgery.
Since abdominal adhesion are quite problematic in abdominal and pelvic surgery, the conventional HA/CMC film are commonly used as an anti-adhesive material. However, such types are difficult to be rolled and delivered through the port of laparoscopic surgical devices due to adherence to the laparoscopic port or other parts of the films. To create an anti-adhesion film with more favorable handling properties and anti-adhesive effect, we developed a novel punctate uneven gelatin film (PU GF). In this study, we examined the physical strength, flexibilities and adhesiveness between film to tissues or film each other, compared to the conventional film and the flat gelatin film (Flat GF). In addition, we investigated the cell proliferation on each film and the anti-adhesive effect of the films and those reattachment possibility using a rat cecum abrasion model. The PU GF showed excellent tensile strength, ductility, and adherence to tissue compared to Flat GF and the conventional film. Moreover, the adherence of PU GF to the other film and to a silicon sheet were much lower than those of the Flat GF and conventional film. The proliferation of cells in PU GF and Flat GF were suppressed compared with control, though increased with time. The anti-adhesive scores of the PU GF after one time and re-attachment were significantly higher than that of non-covered control, although there was no significant difference between that of the conventional film and control. Our findings suggest that PU GF improve handling properties of laparoscopic surgery as it has excellent physical strength, ductility, and adherence to tissue, and low adherence to trocar. In addition, the punctate film may be more useful with the re-attachability without tearing and to retained sufficient anti-adhesion effect.
Tissue engineering, a key component of regenerative medicine, aims to restore the structure and function of damaged organs using combinations of cells, scaffolds, and bioactive factors. In urology, the integration of stem cell biology has fueled significant progress in preclinical models for kidney, bladder, and urethral regeneration. Pluripotent stem cells, such as embryonic stem cells and induced pluripotent stem cells, offer broad differentiation potential, particularly in kidney organoid development. Meanwhile, multipotent stem cells-especially mesenchymal stem cells and urine-derived stem cells-have shown promise in bladder and urethral repair due to their immunomodulatory properties and relative ease of use. Despite these advancements, certain challenges remain: vascularization, functional integration, long-term safety, and scalability continue to limit the clinical application of regenerated organs. In kidney regeneration, issues such as nephron-collecting duct connectivity and urinary outflow remain unresolved. For the bladder and urethra, the need for vascularized, contractile, and innervated tissue complicates scaffold and cell selection. Nonetheless, clinical translation is becoming increasingly realistic. As the field evolves rapidly, it is essential for urologists to remain informed and actively engage in collaborative research. By integrating clinical expertise with basic science, urologists can play a crucial role in guiding regenerative strategies toward effective, patient-specific therapies.
Long-term bladder regeneration has not been successful instead of augmentation with gastrointestinal segments, as is commonly performed for bladder reconstruction. To evaluate whether or not cell-seeded bioabsorbable materials regenerate half-resected bladder in a rabbit model. Female Japanese white rabbits were divided two groups: cell-seeded material (CSM) group and Control (n = 6 each). Control rabbits underwent resection of half the bladder. CSM rabbits were sutured with cell-seeded amniotic membrane and P(LA/CL) material after bladder resection. After 6, 12, and 18 months, rabbits underwent X-ray and cystometry, and bladder tissues after 18 months were subjected to functional and histological analyses. X-ray confirmed the peristaltic movements of the reconstructed bladders in the CSM group. On cystometry, the mean maximum bladder volume, maximum bladder pressure, and 25 mL bladder volume compliance in the CSM group were significantly greater than in the Control group at 6, 12, and 18 months. In addition, organ bath studies showed good contraction under electrical stimulation with increasing stimulation frequency in the CSM group, while, the Control group showed weak contraction on both tests in the central marginal zone. Furthermore, the rates of neovascularization, urothelial and smooth muscle formation, and neurofilamentation in the CSM group were significantly greater than in the Control group. Oral mucosal cell-seeded amniotic membrane and stomach smooth muscle cell-seeded P(LA/CL) scaffold with omentum after abdominal implantation regenerated functional bladder with satisfactory epithelium and smooth muscle without scarring more than 1 year. Impact StatementRegeneration of functional bladder without using gastrointestinal segments has been a huge challenge to urological reconstruction. Various materials, such as nonbioabsorbable materials and biomaterials have been attempted to reconstruct bladder in animal models. However, the long-term results more than a year failed due to the low biocompatibility, high risks, and difficulty creating the materials. In this study, we revealed long-term bladder regeneration using cell-seeded amniotic membrane and P(LA/CL) material in a rabbit model. The new method of bladder reconstruction seems able to regenerate functional bladder with satisfactory bladder epithelium and bladder smooth muscle function without scarring for more than 1 year successfully.
Long-term in vivo observation in large animal model is critical for evaluating the potential of small diameter tissue engineering vascular graft (SDTEVG) in clinical application, but is rarely reported. In this study, a SDTEVG is fabricated by the electrospinning of poly(ε-caprolactone) and subsequent heparin modification. SDTEVG is implanted into canine's abdominal aorta for 511 days in order to investigate its clinical feasibility. An active and robust remodeling process was characterized by a confluent endothelium, macrophage infiltrate, extracellular matrix deposition and remodeling on the explanted graft. The immunohistochemical and immunofluorescence analysis further exhibit the regeneration of endothelium and smooth muscle layer on tunica intima and tunica media, respectively. Thus, long-term follow-up reveals viable neovessel formation beyond graft degradation. Furthermore, the von Kossa staining exhibits no occurrence of calcification. However, although no TEVG failure or rupture happens during the follow-up, the aneurysm is found by both Doppler ultrasonic and gross observation. Consequently, as-prepared TEVG shows promising potential in vascular tissue engineering if it can be appropriately strengthened to prevent the occurrence of aneurysm.
By mimicking the extracellular matrix, nonwoven fabrics can function as scaffolds for tissue engineering application ideally, and they have been characterized regarding their fiber diameter and fiber spacing (spacing size) in vitro. We chronologically examined the in vivo effects of these fabrics on the cellular response and tissue remodeling. Four types of nonwoven polyglycolic acid fabrics (Fabric-0.7, Fabric-0.9, Fabric-3, and Fabric-16 with fiber diameters of 0.7, 0.9, 3.0, and 16.2 μm and spacing sizes of 2.0, 19.3, 19.0, and 825.4 μm, respectively) were implanted into the rat dorsum and subjected to histologic and immunohistochemical analyses from day 3 to 70. With Fabric-0.7, inflammatory cells (mainly M1 macrophages) and myofibroblasts with collagen type III accumulated mainly on the surface of the fabric and did not infiltrate inside the fabric initially, likely due to the narrow fiber space. Massive formation of collagen type I then appeared with the degradation of the fabrics, and finally, the remodeled tissue turned into a dense scar. With Fabric-0.9 and Fabric-3, inflammatory cells (predominantly M2 macrophages) were seen in all layers of the fabric initially. A mild increase in collagen type I was then seen, with few myofibroblasts, and the remodeled tissue ultimately showed a relatively little scar with an adequate thickness of the tissue induced by the fabrics. With Fabric-16, inflammatory cells (predominantly M1 macrophages) infiltrated into all layers of the fabric initially along with many myofibroblasts, especially in the hole. Lately, massive formation of collagen type I was noted due to the slow degradation of the fabric, with the shrinking of the fabric substantially, and the remodeled tissue finally turned to a dense scar. These findings suggest that optimizing the spacing size as well as the fiber diameter of artificial scaffolds may control the cellular response and tissue remodeling and facilitate favorable tissue regeneration without scar formation.
Background We experienced a case of early stage lung cancer involving a morbidly obese patient. Obesity is associated with a higher incidence of surgical complications. We examined the effectiveness of laparoscopic sleeve gastrectomy as a primary weight loss procedure in a morbidly obese patient who required oncological surgery. Case presentation A 64-year-old morbidly obese female with a body mass index of 43.5 kg/m 2 was referred to our hospital to undergo weight loss. A right-sided lung mass was found incidentally on computed tomography conducted in preparation for laparoscopic sleeve gastrectomy, which was performed prior to tumor surgery. As a result, weight loss was achieved within 2.5 months after the laparoscopic sleeve gastrectomy, and the patient’s type-2 diabetes, hypertension, and dyslipidemia, which are linked to obesity, were markedly ameliorated. After a quick intraoperative pathological inspection revealed that the tumor was malignant, thoracoscopic right lung superior lobe resection was performed safely. Conclusions Laparoscopic sleeve gastrectomy proved to be a powerful approach in a case in which a morbidly obese patient with early stage cancer needed to lose weight rapidly.
BACKGROUND: To overcome the unfavorable issues associated with conventional anti-adhesive HA/CMC film, we developed an anti-adhesive thermally cross-linked gelatin film. OBJECTIVE: We tried to clarify the re-attachability of the film and the required properties concerning the film thickness, stiffness and anti-adhesion effect. METHODS: To determine the optimal thickness, 5 kinds of the thickness of gelatin film and the conventional film were analyzed by the tensile test, shearing test, buckling test and tissue injury test. Finally, using the optimal film thickness, we tried to clarify the anti-adhesion effect of the reattached film. RESULTS: The tensile and shearing test showed gelatin films ≥30 μm thick had greater tensile strength and a smaller number of film fractures, than the conventional film. The buckling and tissue injury test showed gelatin films ≥60 μm thick had higher buckling strength and worse injury scores than the conventional film. The anti-adhesive effect of re-attached gelatin film using optimal thickness (30–40 μm) found the anti-adhesion score was significantly better than that of the control. CONCLUSIONS: Provided it has an optimal thickness, gelatin film can be reattached with enough physical strength not to tear, safety stiffness not to induce tissue injury, and a sufficient anti-adhesion effect.
Bax, one of thebcl-2 family genes, is expressed in a number of untransformed cell lines and various breast tissues, whereas only weak or no expression has been detected in breast cancer cell lines and malignant breast tissue. Human breast cancer MCF-7 cells, which have a weakbax gene expression, were stably transfected withpCX2neo bax, encoding humanbax; and two unique clones,MCF-7/bax-1 andMCF-7/bax-2, that expressed different levels ofbax were generated. Sensitivity to cisplatin (CDDP) and etoposide (VP-16) was examined and each stable transfectant was more sensitive to these agents than the parental MCF-7 cells. The degree of enhancement in sensitivity to these anticancer agents was dependent on the expression level ofbax. The enzyme-linked immunosorbent assay (ELISA), which quantifies DNA damage, demonstrated that this sensitization was due to apoptosis. Thus, we suggest that exogenousbax-α overexpression may be one of the factors determining cellular chemosensitivity in MCF-7 breast cancer cells and that it could be applied therapeutically to enhance chemosensitivity in breast cancer cells.
We simultaneously quantified fecal bile acids (BAs) and short-chain fatty acids (SCFAs) florescence labeled with 9chloromethylanthracene using high-performance liquid chromatography-fluorescence (HPLC-FL) and developed an inexpensive and highly accurate method for determining the ratio of BAs and SCFAs in colorectal cancer patients and healthy controls.Samples were extracted with hexane/ether, and extractants were measured using HPLC-FL.The healthy subject group included 17 men and 21 women, whereas the colorectal cancer group included patients with cancer in the rectum (3 men, 2 women), sigmoid colon (3 men, 2 women), and ascending colon (2 men, 3 women).The contribution rate of determination for calibration curves was >0.99, and the additional recovery rate was 67.2%-107% for the simultaneous quantification of fecal BAs and SCFAs using HPLC-FL.Intra-day and inter-day variations in the control feces ranged 2.4%-5.1% and 3.1%-9.2%,respectively.The proportion of primary BAs to total BAs was higher in the colorectal cancer group (87.3%) than in the healthy subject group (67.9%).A significant difference was observed in the ratio of BAs to butyric acid between healthy subject and colorectal cancer groups.BA levels were higher in the colorectal cancer group.Thus, the ratio of total BAs to butyric acid may be a better predictor of colon cancer than BAs or SCFAs alone.
Polyglycolic acid (PGA) mesh fabric is widely used for reinforcing injured tissues during surgeries. However, PGA induces chronic inflammation and adhesion. The purpose of this study is to develop PGA reinforcement "without PGA-induced adhesion." We developed a reinforcement fabric unified with PGA mesh and alginate foam. The antiadhesive effects of sodium alginate foam and calcium alginate foam were evaluated in rats. Sodium alginate foam unified with PGA mesh fabric exhibited strong effects that limit the extent and severity of adhesion, whereas calcium alginate foam unified with PGA mesh was less effective in preventing adhesion. In the sodium alginate group, fibroblasts and collagen fibers around implanted sites were sparse and the material degraded rapidly by macrophage ingestion. Fibroblasts and collagen fibers play a major role in adhesion formation and their excessive proliferation results in postoperative adhesion. Thus, inhibiting their increase is the key in preventing PGA-induced adhesion. The reinforcement that is composed of PGA mesh unified with sodium alginate foam strongly inhibited PGA-induced adhesion and showed excellent handling during surgery and could be easily applied with a one-step procedure.
To create more useful, effective and safer anti-adhesion materials, we developed a thermally cross-linked gelatin film. In this study, we examined the physical properties of the film such as the physical strength and the adhesiveness to reveal the handling properties and biological properties, such as the anti-adhesion effect, the influence on cell proliferation, and the cytotoxicity to reveal the anti-adhesion mechanism, especially in comparison with the conventional hyaluronic acid and carboxymethylcellulose film (the conventional film). A tensile test under dry and wet conditions and shearing stress test showed that the gelatin film has significant higher maximum tensile stress and fracture strain than the conventional film. In the study using a rat model of cecum adhesion, the anti-adhesion effect of the gelatin film was significantly superior to that of the conventional film. In the cell proliferation test, the number of fibroblast cells on the gelatin film increased at each time point, while no cell proliferation was observed on the conventional film. Furthermore, in the cytotoxicity test using a colony assay and Live/Dead assay, the extract of the gelatin film had no cytotoxicity, while the extract of the conventional film had cytotoxicity considerably. These results suggest that the gelatin film provides better handling than the conventional film, due to better physical strength and ductility of the film. In addition, the gelatin film has a significantly greater anti-adhesion effect than the conventional film without any cytotoxicity. Therefore, the gelatin film is quite favorable as an anti-adhesion material. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 689-696, 2018.
Postoperative air leaks remain a major cause of morbidity after lung resection. This study evaluated the effect of a combination of polyglycolic acid (PGA) sheet and alginate gel on pulmonary air leaks in rats. Four pulmonary sealing materials were evaluated in lung injury: fibrin glue, combination of PGA sheet and fibrin glue, alginate gel, and combination of PGA sheet and alginate gel. With the airway pressure maintained at 20 cmH 2 O, a 2 mm deep puncture wound was created on the lung surface using a needle. Lowering the airway pressure to 5 cmH 2 O, each sealing material was applied. The lowest airway pressure that broke the seal was measured. The seal-breaking pressure in each experimental group was fibrin, 10.4±6.8 cmH 2 O; PGA + fibrin, 13.5±6.5 cmH 2 O; alginate gel, 10.3±4.9 cmH 2 O; and PGA + alginate, 35.8±11.9 cmH 2 O, respectively. The seal-breaking pressure was significantly greater in the PGA + alginate gel group than in the other groups (p<0.01). There were no significant differences among the other three groups. Alginate gel combined with a PGA sheet is a promising alternative to fibrin glue as a safe and low-cost material for air leak prevention in pulmonary surgery.
To create anti-adhesive materials to be more effective and safer, we developed a thermally cross-linked gelatin film that showed superior anti-adhesive effects with excellent peritoneal regeneration. However, it may act as a convenient scaffold for tumor cell growth, thereby accelerating peritoneal dissemination when used in surgery for abdominal tumors. In this study, we tried to clarify this issue using mouse carcinomatous peritonitis models. First, we examined the in vitro tumor cell growth of mouse B16 melanoma or Colon26 cells on the gelatin film or the conventional hyarulonate/carboxymethylcellulose film. Tumor cell growth on each film was significantly lower than that of the control (no film). Next, we conducted the following in vivo experiments: After the parietal peritoneum was partially removed and covered with each film or without any film, mice were inoculated intraperitoneally with B16 melanoma or Colon26/Nluc cells expressing NanoLuc luciferase gene. At 7 days after the operation, we measured the weight of B16 melanoma tumors or the NanoLuc activity of Colon26/Nluc cells using in vivo imaging at the injured sites. There were no significant differences in the weight of the tumors and the NanoLuc activity among the three groups. We also observed the survival time of mice receiving the same operation and treatments. There was no significant difference in the survival time among the three groups. These results suggest that the gelatin film will likely not accelerate peritoneal dissemination as a convenient scaffold for tumor cell growth when used in surgery for abdominal tumors. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 2122-2130, 2018.
Background:. Seroma formation is a major complication following latissimus dorsi (LD) flap transfer for breast reconstruction. We implanted a nonwoven polyglycolic acid (PGA) fabric—a biodegradable polymer—in the LD flap donor site and examined its effect on postoperative seroma formation and resolution in a comparative study on 38 patients undergoing primary 1-stage breast reconstruction by LD flap. Method:. A PGA treatment group had a PGA fabric placed in the donor wound (PGA group, n = 20), whereas a second group was treated with standard donor site closure (control group, n = 18). The incidence of seromas was comparable between the groups. Result:. There was a significant reduction in aspiration volume by needle aspiration after drain removal (P < 0.05) and in the time until seroma resolution (P < 0.01) in the PGA group compared with the control group. Conclusion:. These results indicate that application of PGA at the LD donor site is useful in controlling postoperative seromas.
A reduction in mortality with the early use of tranexamic acid has been demonstrated in severely injured patients who are bleeding. However, the modest treatment effect with no reduction in blood transfusion has raised concerns. The aim of the present study was to estimate the effectiveness of regular use of tranexamic acid in severely injured patients.
AimAdhesion after pelvic surgery causes infertility, ectopic pregnancy, and ileus or abdominal pain. The materials currently available for clinical use are insufficient. The purpose of this study was to develop an anti-adhesive material that overcomes the limitations of conventional anti-adhesive agents.MethodsThe adhesion prevention effects of three methods - a two-layered sheet composed of gelatin film and gelatin sponge, Seprafilm and INTERCEED - were evaluated in 37 dogs. Anti-adhesive effects were investigated macroscopically and microscopically in a cauterized uterus adhesion model. Cell growth on the materials in vitro using human peritoneal mesothelial cells, fibroblasts and uterine smooth muscle cells were also evaluated.ResultsThe two-layered gelatin sheet had significantly superior anti-adhesive effects compared to the conventional materials (Seprafilm and INTERCEED). A single-cell layer of mature mesothelium formed three weeks after surgery in the gelatin group. Peritoneum regeneration in the Seprafilm and INTERCEED groups was delayed and incomplete in the early phase. Little inflammation around the materials occurred and cell growth was significantly proliferated with the gelatin sheet.ConclusionThe anti-adhesive effects of a two-layered gelatin sheet were superior to conventional agents in a cauterized canine uterus model, demonstrating early regeneration of the peritoneum, little inflammation and material endurance. The newly developed two-layered gelatin sheet is a useful option as an anti-adhesive agent for deeply injured and hemorrhagic sites.
Background/objective: Uncontrolled surgical bleeding is associated with increased morbidity, mortality, and hospital cost. Topical hemostatic agents available today have problems controlling hemostatic effects; furthermore, their handling is difficult and they are unsafe. Methods: We devised a new hemostatic agent comprising gelatin sponge and film designed to be applied to the bleeding site, thereby creating a topical hemostatic agent made of gelatin alone. The gelatin was prepared by alkali treatment to eliminate viral activity. Hemostatic effects, surgical handling, and tissue reactions of the materials, namely a two-layer sheet of gelatin, TachoSil, and gelatin sponge, were evaluated using 21 dogs' spleens. Results: The two-layer gelatin sheet and gelatin sponge exhibited superior hemostatic effects (100% hemostasis completed) compared with TachoSil (0-17% hemostasis). The gelatin matrix immediately absorbed blood flowing from wounds and activated the autologous components in the absorbed blood that promoted coagulation at the bleeding site. The two-layer gelatin sheet had the best surgical handling among the evaluated materials. Materials made of gelatin were associated with fewer inflammatory reactions compared with materials of TachoSil. Conclusion: The two-layer sheet of gelatin is a useful topical agent because of its superior hemostatic effects and usability, and is associated with a lower risk of transmitting diseases and inflammatory reactions. (C) 2016 Asian Surgical Association and Taiwan Robotic Surgery Association. Publishing services by Elsevier B.V.
Background and study aims: Recently, the shielding method with polyglycolic acid (PGA) fabric and fibrin glue (P-F method) has been reported to prevent serious complications after endoscopic submucosal dissection (ESD). However, the effectiveness and mechanism to prevent complications by this method remain unclear and the corresponding basic research has not been fully conducted. Methods and results: We examined the effectiveness and mechanism of the P-F method, using a surgical ESD model of canine stomach and in vitro experiments. In the model experiment treated by P-F method or no treatment (control), ulcer perforation or penetration occurred only in the control group, but not in the P-F group. Microscopically, the P-F group showed less damages of the ulcer lesion than that of the control group, showing thicker granulation tissues including PGA fibers on the third day and excellent mucosal regeneration on the fourteenth day. In vitro culture experiments showed that fibroblasts proliferated at a significantly higher rate on PGA than on fibrin or a complex thereof. However, under hydrochloric acid treatment, fibroblasts were protected by fibrin, followed by the complex of both, and PGA. Conclusion: The P-F method exhibited a protective effect against gastric juice by fibrin glue to reduce tissue damages and a scaffold function of PGA fabric to induce better granulation formation at the earlier phase, resulting in excellent long-term tissue repair, on ulcer lesion following ESD, although the results were based on basic experiments.