The lateral flow (immuno)assay is a relatively old diagnostic platform that was developed in the 1980s. Over the almost 30 years since, a very diverse panel of lateral flow immunoassays has been developed and marketed. At the moment the platform is being transformed into a modern diagnostic tool that can be integrated with nowadays technologies, such as optical and electrochemical transducers and wireless data transfer. In addition, more sensitive detection principles have become available. The way forward for this technology is the development of sensitive, multianalyte, and quantitative assays that can compete with some of the diagnostics now used in the laboratory. A lateral flow reader dedicated to microarray and/or quantitative assays is absolutely needed to process the data to the user-friendly results. Challenges and future directions of the lateral flow platform are the combination with nucleic acid amplification procedures and the further integration with paper diagnostics. As is evident from the scientific literature and the commercial market, the lateral flow diagnostic platform is being transformed into a competitive diagnostic by the combination with and the incorporation of advanced technologies.
Arboviruses such as West Nile Virus (WNV) and Usutu Virus (USUV) are emerging pathogens that circulate between mosquitoes and birds, occasionally spilling over into humans and horses. Current serological screening methods require access to a well-equipped laboratory and are not currently available for on-site analysis. As a proof of concept, we propose here a species-independent lateral flow microarray immunoassay (LMIA) able to quickly detect and distinguish between WNV Non-Structural 1 (NS1) and USUV NS1-specific antibodies. A double antigen approach was used to test sera collected from humans, horses, European jackdaws (Corvus monedula), and common blackbirds (Turdus merula). Optimization of the concentration of capture antigen spotted on the LMIA membrane and the amount of detection antigen conjugated to detector particles indicated that maximizing both parameters increased assay sensitivity. Upon screening of a larger serum panel, the optimized LMIA showed significantly higher spot intensity for a homologous binding event. Using a Receiver Operating Characteristics (ROC) curve, WNV NS1 LMIA results in humans, horses, and C. monedula showed good correlation when compared to “gold standard” WNV FRNT90. The most optimal derived sensitivity and specificity of the WNV NS1 LMIA relative to corresponding WNV FRNT90-confirmed sera were determined to be 96% and 86%, respectively. While further optimization is required, this study demonstrates the feasibility of developing a species-independent LMIA for on-site analysis of WNV, USUV, and other arboviruses. Such a tool would be useful for the on-site screening and monitoring of relevant species in more remote or low-income regions.
The Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) pandemic has once more emphasized the urgent need for accurate and fast point-of-care (POC) diagnostics for outbreak control and prevention. The main challenge in the development of POC in vitro diagnostics (IVD) is to combine a short time to result with a high sensitivity, and to keep the testing cost-effective. In this respect, sensors based on photonic integrated circuits (PICs) may offer advantages as they have features such as a high analytical sensitivity, capability for multiplexing, ease of miniaturization, and the potential for high-volume manufacturing. One special type of PIC sensor is the asymmetric Mach–Zehnder Interferometer (aMZI), which is characterized by a high and tunable analytical sensitivity. The current work describes the application of an aMZI-based biosensor platform for sensitive and multiplex detection of anti-SARS-CoV-2 antibodies in human plasma samples using the spike protein (SP), the receptor-binding domain (RBD), and the nucleocapsid protein (NP) as target antigens. The results are in good agreement with several CE-IVD marked reference methods and demonstrate the potential of the aMZI biosensor technology for further development into a photonic IVD platform.
Pesticides are used in agriculture to prevent pests. Chlorpyrifos (CHLP) is an insecticide with potentially detrimental effects on humans, bees, and the aquatic environment. Its effects have led to a total ban by the European Union (EU), but outside the EU, CHLP is still produced and used. An indirect lateral flow immunoassay (LFIA) for the detection of CHLP was developed and integrated into a cassette to create a lateral flow device (LFD). Species-specific reporter antibodies were coupled to carbon nanoparticles to create a detector conjugate. Water samples were mixed with a specific CHLP monoclonal antibody and detector conjugate and applied to the LFD. Dose-response curves elicited the detection of low concentrations of CHLP (<1 µg/L). This sensitivity was recorded through a rapid handheld digital imaging device but also visually by naked eye. The CHLP LFD was applied to a range of European surface water samples, fortified with CHLP, revealing a sensitivity in these matrices of 2 µg/L, both by digital and visual analysis. To improve the simplicity of the CHLP LFIA, the assay reagents were dried in tubes, enabling to carry out the test by simply adding water samples and inserting the LFIA strips. This CHLP LFIA is thus suited for the on-site screening of surface waters.
A competitive lateral flow immunoassay using amorphous carbon nanoparticles (CNPs) and nonimmunoglobulin antigen has been developed for the rapid detection of adulteration of cow?s milk with buffalo?s milk. Purified polyclonal antibodies against a specific buffalo?s milk protein fraction were conjugated to CNPs and sprayed on a conjugate pad. The test line consisted of buffalo?s skimmed milk proteins (1.6 ?g/cm), while the control line contained anti-rabbit antibodies raised in goat (0.5 ?g/cm). In the test procedure milk sample is mixed with 100 mM borate buffer (pH 8.8 containing 1% BSA and 0.05% Tween 20) and pipetted onto the sample-cum-conjugate pad. A black/grey test line can be observed if the sample is free from buffalo?s milk. The sensitivity of the test i.e. no visible test line is 5% adulteration of cow?s milk with buffalo?s milk. The test has applicability at the milk receiving stations and can be applied to heated milk samples.
Escherichia coli strains carrying Shiga toxins 1 and 2 (stx1 and stx2), intimin (eae), and hemolysin (ehxA) production genes were found in grass shoot, rhizosphere soil, and stable manure samples from a small-scale cattle farm located at the center of Netherlands, using cultivation-dependent and -independent microbiological detection techniques. Pasture land with grazing heifers in the first year of sampling in 2014 and without grazing cattle in 2015 was physically separated from the stable that housed rose calves during both years. Manure from the stable was applied to pasture via injection into soil once per year in early spring. Among a variety of 35 phylogenetic distinctly related E. coli strains, one large group consisting of 21 closely resembling E. coli O150:H2 (18), O98:H21 (2), and O84:H2 (1) strains, all belonging to phylogenetic group B1 and carrying all screened virulence traits, was found present on grass shoots (10), rhizosphere soil (3), and stable manure (8) in 2014, but not anymore in 2015 when grazing heifers were absent. Presence and absence of these strains, obtained via enrichments, were confirmed via molecular detection using PCR-NALFIA in all ecosystems in both years. We propose that this group of Shiga toxin-producing E. coli phylogenetic group B1 strains was originally introduced via stable manure injection into the pasture. Upon grazing, these potential pathogens proliferated in the intestinal track systems of the heifers resulting in defecation with higher loads of the STEC strain onto the grass cover. The STEC strain was further smeared over the field via the hooves of the heifers resulting in augmentation of the potential pathogen in the pasture in 2014, whereas in 2015, in the absence of heifers, no augmentation occurred and only a more diverse group of potentially mild virulent E. coli phylogenetic group A and B1 strains, indigenous to pasture plants, remained present. Via this model, it was postulated that human pathogens can circulate between plants and farm animals, using the plant as an alternative ecosystem. These data indicate that grazed pasture must be considered as a potential carrier of human pathogenic E. coli strains and possibly also of other pathogens.
In this study we explore the potential of using Fourier-transform infrared (FTIR) spectra of trifluoroacetate-protein and peptide complexes for monitoring proteolytic reactions. The idea of treating dry-films of protein hydrolysates with trifluoroacetic acid (TFA) prior to FTIR analysis is based on the unique properties of TFA. By adding a large excess of TFA to protein hydrolysate samples, the possible protonation sites of the proteins and peptides will be saturated. In addition, TFA has a low boiling point when protonated as well as complex-forming abilities. When forming TFA-treated dry-films of protein hydrolysates, the excess TFA will evaporate and the deprotonated acid (CF 3 COO − ) will interact as a counter ion with the positive charges on the sample materials. In the study, spectral changes in TFA-treated dry-films of protein hydrolysates from a pure protein and poultry by-products, were compared to the FTIR fingerprints of untreated dry-films. The results show that time-dependent information related to proteolytic reactions and, consequently, on the characteristics of the protein hydrolysates can be obtained. With additional developments, FTIR on dry-films treated with TFA may be regarded as a potential future tool for the analysis of all types of proteolytic reactions in the laboratory as well as in industry.
Nucleic acid lateral flow assays (NALFA) are often performed with gold nanoparticles. These are typically associated with ligand-labeled PCR amplicons via affinity interactions of adsorbed/conjugated proteins. Otherwise, they are conjugated to specific ssDNA sequences that hybridize to the target sequence. To avoid the need to generate ssDNA and to reduce the costs associated with primer labeling and antibody use, NALFA assays were developed that allow the direct detection of PCR amplicons using conjugates of a DNA binding protein with carbon nanoparticles (CNPs). The target gene encoding 16S ribosomal RNA of Escherichia coli was amplified by PCR using a single fluorophore-labeled forward primer and a reverse primer extended with the binding sequence of the bacteriophage lambda Cro repressor protein. Three different detection approaches were evaluated: (a) scCro/CNPs conjugate (black color), (b) HRP-scCro enzyme conjugate (red color), and (c) HRP-scCro/CNPs conjugate for dual color development. The limits of detection were between 6.9 and 10.4 ng of PCR product for all three approaches. These correspond to 3.0 to 4.5 × 103 CFU·mL−1. The single-step scCro/CNP approach proved to be the fastest one to perform and gave no false-positive signals. It also showed a broad dynamic range even though the signal intensities were lower compared to the enzyme-amplified tests. However, the latter ones produced some background signal. In our perception, the application of scCro in lateral flow assays to bind dsDNA appears to be an excellent alternative to the use of small tags that have to be chemically linked to synthetic primers. Finally, the approach is generic because any primer sequence can be extended with the specific scCro binding sequence.
Lateral Flow Immunoassays (LFIAs) allow for rapid, low-cost, screening of many biomolecules such as food allergens. Despite being classified as rapid tests, many LFIAs take 10–20 min to complete. For a really high-speed LFIA, it is necessary to assess antibody association kinetics. By using a label-free optical technique such as Surface Plasmon Resonance (SPR), it is possible to screen crude monoclonal antibody (mAb) preparations for their association rates against a target. Herein, we describe an SPR-based method for screening and selecting crude anti-hazelnut antibodies based on their relative association rates, cross reactivity and sandwich pairing capabilities, for subsequent application in a rapid ligand binding assay. Thanks to the SPR selection process, only the fast mAb (F-50-6B12) and the slow (S-50-5H9) mAb needed purification for labelling with carbon nanoparticles to exploit high-speed LFIA prototypes. The kinetics observed in SPR were reflected in LFIA, with the test line appearing within 30 s, almost two times faster when F-50-6B12 was used, compared with S-50-5H9. Additionally, the LFIAs have demonstrated their future applicability to real life samples by detecting hazelnut in the sub-ppm range in a cookie matrix. Finally, these LFIAs not only provide a qualitative result when read visually, but also generate semi-quantitative data when exploiting freely downloadable smartphone apps.
Rapid and quantitative prostate-specific antigen (PSA) biomarker detection would be beneficial to cancer diagnostics, improving early detection and therefore increasing chances of survival. Nanoparticle-based detection is routinely used in one-step nitrocellulose-based lateral flow (LF) immunoassays; however, it is well established within the scientific diagnostic community that LF technology lacks sensitivity for measuring biomarkers, such as prostate-specific antigen (PSA). A trend in point-of-care (POC) protein biomarker quantitation is the miniaturization of immunoassays in microfluidic devices. This work aimed at testing the feasibility of carbon and gold nanoparticles as immunoassay labels for PSA detection with cost-effective optical detection in a novel microfluidic POC platform called microcapillary film (MCF), consisting of a parallel array of fluoropolymer microcapillaries with 200-μm internal diameter. With neutravidin-coated carbon, nanoparticles were able to quantify an immobilized biotinylated monoclonal antibody (coating solution from 10 to 40 μg/ml) and PSA was successfully quantified in a sandwich assay using silver-enhanced gold nanoparticles and a flatbed scanner; yet, the dynamic range was limited to 10–100 ng/ml. Although direct optical detection of PSA without enzymatic amplification or fluorophores is possible and technically appealing for the simplified fluidics and signal scanning setups involved, ultimately, the binding of a thin layer of nanoparticles onto the wall of transparent microcapillaries is not sufficient to cause a significant drop on the optical colorimetric signal. Future studies will explore the use of fluorescence nanoparticles.
The distribution of inkjet-printed biomolecules in porous nitrocellulose substrates often results in a non-homogeneous spot morphology commonly referred to as 'doughnut-shaped' spots. We have studied the influence of Pluronic F127 (an amphiphilic surfactant) on the functionality of inkjet-printed primary antibody molecules and on the final assay result by performing a one-step antibody binding assay in the nitrocellulose substrate. The primary antibody was printed with and without Pluronic, followed by the addition of double-labelled amplicons as antigen molecules and a fluorophore-labelled streptavidin as detection conjugate. The distribution of the fluorescence intensity down into the nitrocellulose substrate was investigated by confocal laser scanning microscopy in 'Z' stacking mode. Each horizontal slice was further analysed by applying a concentric ring format and the fluorescence intensity in each slice was represented in a colour-coded way. The mean and total fluorescence intensity of the antibody binding assay (fluorescent streptavidin) showed a peak at 0.2% (w/v) Pluronic F127. In addition, an improved spot morphology was observed also peaking at the same Pluronic concentration. Subsequently, we investigated the direct influence of Pluronic F127 on the location of the primary antibody molecules by labelling these molecules with the fluorophore Alexa-488. Our results show that upon increasing the concentration of Pluronic F127 in the printing buffer, the spot diameter increased and the number of primary antibody molecules bound in the spot area gradually decreased. This was confirmed by analysing the distribution of fluorescently labelled primary antibody molecules down into the membrane layers. We conclude that a particular ratio between primary antibody and Pluronic F127 molecules in combination with available substrate binding capacity results in an optimal orientation, that is Fab-UP, of the primary antibody molecules. Consequently, an increased number of antigen molecules (in our case the labelled amplicons) and of the fluorescent detection conjugate (streptavidin) will give an optimal signal. Moreover, distribution of the primary antibody molecules was more homogeneous at the optimal Pluronic F127 concentration, contributing to the better spot morphology observed.
Disease incidences related to Escherichia coli and Salmonella enterica infections by consumption of (fresh) vegetables, sprouts and occasionally fruits made clear that these pathogens are not only transmitted to humans via the 'classical' routes of meat, eggs and dairy products, but also can be transmitted to humans via plants or products derived from plants. Nowadays, it is of major concern that these human pathogens, especially the ones belonging to the taxonomical family of Enterobacteriaceae, become adapted to environmental habitats without losing their virulence to humans. Adaptation to the plant environment would lead to longer persistence in plants, increasing their chances on transmission to humans via consumption of plant-derived food. One of the mechanisms of adaptation to the plant environment in human pathogens, proposed in this paper, is horizontal transfer of genes from different microbial communities present in the arable ecosystem, like the ones originating from soil, animal digestive track systems (manure), water and plants themselves. Genes that would confer better adaptation to the phytosphere might be genes involved in plant colonization, stress resistance and nutrient acquisition and utilization. Because human pathogenic enterics often were prone to genetic exchanges via phages and conjugative plasmids, it was postulated that these genetic elements may be hold key responsible for horizontal gene transfers between human pathogens and indigenous microbes in agroproduction systems. In analogy to zoonosis, we coin the term phytonosis for a human pathogen that is transmitted via plants and not exclusively via animals.
ABSTRACT The resistance of Plasmodium falciparum to some antimalarial drugs is linked to single-nucleotide polymorphisms (SNPs). Currently, there are no methods for the identification of resistant parasites that are sufficiently simple, cheap, and fast enough to be performed at point-of-care, i.e., in local hospitals where drugs are prescribed. Primer extension methods (PEXT) were developed to identify 4 SNPs in P. falciparum positioned at amino acids 86, 184, and 1246 of the P. falciparum multidrug resistance 1 gene ( pfmdr1 ) and amino acid 76 of the chloroquine resistance transporter gene ( pfcrt ). The PEXT products were visualized by a nucleic acid lateral flow immunoassay (NALFIA) with carbon nanoparticles as the detection labels. PCR-PEXT-NALFIAs showed good correlation to the reference methods, quantitative PCR (qPCR) or direct amplicon sequence analysis, in an initial open-label evaluation with 17 field samples. The tests were further evaluated in a blind study design in a set of 150 patient isolates. High specificities of 98 to 100% were found for all 4 PCR-PEXT genotyping assays. The sensitivities ranged from 75% to 100% when all PEXT-positive tests were considered. A number of samples with a low parasite density were successfully characterized by the reference methods but failed to generate a result in the PCR-PEXT-NALFIA, particularly those samples with microscopy-negative subpatent infections. This proof-of principle study validates the use of PCR-PEXT-NALFIA for the detection of resistance-associated mutations in P. falciparum , particularly for microscopy-positive infections. Although it requires a standard thermal cycler, the procedure is cheap and rapid and thus a potentially valuable tool for point-of-care detection in developing countries.
During the drying of inkjet printed droplets, the solute particles (IgG-Alexa-635 molecules) in the drop may distribute unevenly on the substrate, resulting in a “coffee-stain” spot morphology.
Drying a fresh lutein-enriched egg-yolk beverage would extend its shelf life, however, functional properties should not be affected. It was investigated whether consumption of a dried beverage containing lutein-enriched egg-yolk significantly increases serum lutein.One-hundred healthy young subjects participated in this 6-weeks randomized controlled study. Subjects consumed either a "plain" control beverage (n = 26), a fresh lutein-enriched egg-yolk beverage (n = 25), a dried version of this beverage (n = 25), or a beverage composed of the dried individual components of the drink (n = 24).The fresh and both dried versions of the lutein-enriched egg-yolk beverage were able to increase serum lutein levels after 6 weeks of consumption (lutein change: -38 +/-47 nmol/L, +304 +/- 113 nmol/L, +148+/-79 nmol/L and +178+/-83 nmol/L for control, fresh, dried and combined dried group respectively; p<0.001). No significant change in serum cholesterol level was seen in the beverages containing lutein-enriched egg-yolk compared to the control drink.
We have developed a rapid mastitis detection test based on the immobilization of tag-specific antibody molecules, the binding of double-tagged amplicons, and as a secondary signal a conjugate of black carbon nanoparticles having molecules of a fusion protein of neutrAvidin and alkaline phosphatase at their surface. The antibodies were inkjet printed onto three different nitrocellulose membrane slides, Unisart (Sartorius), FAST (GE Whatman), and Oncyte-Avid (Grace-Biolabs), and the final assay signals on these slides were compared. The blackness of the spots was determined by flatbed scanning and assessment of the pixel gray volume using TotalLab image analysis software. The black spots could be easily read by the naked eye. We successfully demonstrated the detection of specific amplicons from mastitis-causing pathogens in less than 3 h. Using a similar protocol, we also showed that it was possible to detect specific amplicons from four different mastitis-causing pathogens (six strains) on the same pad. The influence of two different printing buffers, phosphate-buffered saline (pH 7.4) and carbonate buffer (pH 9.6), on the functionality of the primary antibodies was also compared.
Rapid analytical methods enabling the determination of diverse targets are essential in a number of research areas, from clinical diagnostics to feed and food quality and safety. Herein, the development of a quantitative immunochromatographic assay for the detection of the synthetic phytoregulator forchlorfenuron (CPPU) is described. The competitive lateral flow immunoassay (LFIA) was based on the immobilization onto a nitrocellulose membrane of an ovalbumin-CPPU conjugate (test line) and on the use of an immunodetection ligand consisting of carbon nanoparticles labeled with an anti-CPPU monoclonal antibody through interaction with a secondary antibody. The presence of CPPU in horticultural samples was visually interpreted by the decrease in the black signal intensity of the test line, according to the competitive character of the format. The quantitative determination of the analyte was easily performed by a two-step procedure consisting of flatbed scanning of the strips followed by computer-based image analysis of the pixel gray volumes of the test lines. Under optimized conditions, the immunochromatographic test afforded a limit of quantification in buffer of 89 ng/L. The accuracy of the strip test was assessed by the analysis of fruit samples with incurred residues, and the obtained results were compared with those derived from two reference methods, ELISA and HPLC. The LOQ of the CPPU-specific LFIA in kiwifruits and grapes was established at 33.4 μg/kg. The excellent analytical performance of the developed strip test demonstrates the potential of immunochromatographic assays for the quantitative monitoring of small organic molecules in complex matrices.