The mutualisation of analytical platforms might be used to address rising healthcare costs. Our study aimed to evaluate the feasibility of networking a unique matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) system for common use in several university hospitals in Brussels, Belgium. During a one-month period, 1,055 successive bacterial isolates from the Brugmann University Hospital were identified on-site using conventional techniques; these same isolates were also identified using a MALDI-TOF MS system at the Porte de Hal Laboratory by sending target plates and identification projects via transportation and the INFECTIO_MALDI software (Infopartner, Nancy, France), respectively. The occurrence of transmission problems (<2 %) and human errors (<1 %) suggested that the system was sufficiently robust to be implemented in a network. With a median time-to-identification of 5 h and 11 min (78 min, min-max: 154-547), MALDI-TOF MS networking always provided a faster identification result than conventional techniques, except when chromogenic culture media and oxidase tests were used (p < 0.0001). However, the limited clinical benefits of the chromogenic culture media do not support their extra cost. Our financial analysis also suggested that MALDI-TOF MS networking could lead to substantial annual cost savings. MALDI-TOF MS networking presents many advantages, and few conventional techniques (optochin and oxidase tests) are required to ensure the same quality in patient care from the distant laboratory. Nevertheless, such networking should not be considered unless there is a reorganisation of workflow, efficient communication between teams, qualified technologists and a reliable IT department and helpdesk to manage potential connectivity problems.
Objectives To evaluate the use of the new enzyme-linked immunosorbent assay, the ProSpecT Campylobacter Microplate Assay (Alexon-Trend, Minneapolis, MN, USA), which allows 2-h detection of both Campylobacter jejuni and Campylobacter coli antigen directly in stool specimens.Methods Over 4 months, all stool samples preserved in Cary-Blair medium, or fresh specimens, from non-hospitalized children and HIV-infected patients (adults and children), submitted to our laboratory were evaluated with the ProSpecT Campylobacter Microplate Assay. Results were compared with those obtained by routine culture methods using both a specific medium and a filtration method for the recovery of Campylobacter spp.Results Of the 1205 stool specimens cultured, 101 were found to be positive for either C. jejuni or C. coli, giving an overall recovery rate of 8.38%. Ninety samples were positive by both culture and ProSpecT Campylobacter Microplate Assay, and 11 were positive by culture only, giving a sensitivity of 89.1%. In addition, of 1104 samples negative by culture, 25 were initially positive by ProSpecT Campylobacter Microplate Assay. We found no cross-reaction with other bacterial enteropathogens isolated from stool specimens. These results thus confirm a high specificity (97.7%) for both C. jejuni and C. coli. The positive and negative predictive values found were 78.3% and 99%, respectively. There was no statistically significant difference in sensitivity and specificity if the stool was fresh or preserved with Cary-Blair medium.Conclusion These data suggest that the ProSpecT Campylobacter Microplate Assay is a rapid and easy-to-use test for the detection of both C. jejuni and C. coli in stool specimens. It could be used for patients for whom early antibiotic therapy is needed or for epidemiologic studies.