The use of rotating hinge (RH) prostheses for severe primary as well as revision arthroplasty is widely established. Aim of this study was to investigate long term results of a new RH prosthesis (EnduRo®, B Braun, Germany), which uses carbon-fiber reinforced poly-ether-ether-ketone (CFR PEEK) as a new bearing material, first time used in knee arthroplasty. Fifty-six consecutive patients, who received the EnduRo® RH prosthesis were included in this prospective study: 21 patients (37.5%) received the prosthesis as a primary total knee arthroplasty (TKA) and 35 patients (62.5%) underwent revision total knee arthroplasties (rTKA). Clinical and radiographic examinations were performed preoperatively as well as postoperatively after 3 and 12 months and annually thereafter. Min. Follow up was 7 and mean follow up 9,3 years. Clinical examination included Knee Society Score (KSS), Western Ontario and McMaster Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), and range of motion (ROM). Competing risk analysis was assessed for survival with respect to indication and failure mode. KSS, WOMAC, OKS, and ROM significantly improved from the preoperative to the follow up investigations (p < 0.0001). There was no difference in clinical outcome between the primary and the revision group. The overall cumulative incidence for revision for any reason was 23.6% and the cumulative incidence for complications associated with failure of the prothesis was 5.6% at 7 years, respectively. Complications occurred more frequently in the revision group (p = 0.002). The evaluated RH prosthesis provided reliable and durable results with a minimum follow-up of 7 years. Prosthesis survival was successful considering the complexity of cases. The use of this RH system in primary patients showed high survival rates. Long-term functional and clinical results proved to be satisfying in both revision and primary cases. No adverse events were associated with the new bearing material CFR-PEEK.
Ten to twenty percent of patients are dissatisfied with the clinical result after total knee arthroplasty (TKA). Aim of this study was to investigate the impact of personality traits on patient satisfaction and subjective outcome of TKA.We investigated 80 patients with 86 computer navigated TKAs (Emotion®, B Braun Aesculap) and asked for patient satisfaction. We divided patients into two groups (satisfied or dissatisfied). 12 personality traits were tested by an independent psychologist, using the Freiburg Personality Inventory (FPI-R). Postoperative examination included Knee Society Score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC) and the Visual Analogue Scale (VAS). Radiologic investigation was done in all patients.84% of our patients were satisfied, while 16% were not satisfied with clinical outcome. The FPI-R showed statistically significant influence of four personality traits on patient satisfaction: life satisfaction (ρ = 0.006), performance orientation (ρ =0.015), somatic distress (ρ = 0.001), and emotional stability (ρ = 0.002). All clinical scores (VAS, WOMAC, and KSS) showed significant better results in the satisfied patient group. Radiological examination showed optimal alignment of all TKAs. There were no complications requiring revision surgery in both groups.The results of our study show that personality traits may influence patient satisfaction and clinical outcome after TKA. Thus, patients personality traits may be a useful predictive factor for postoperative satisfaction after TKA.
Introduction. Increasing interest developed in the use of carbon-fiber-reinforced-poly-ether-ether-ketones (CFR-PEEK) as an alternative bearing material in knee arthroplasty. The effects of CFR-PEEK wear in in vitro and animal studies are controversially discussed, as there are no data available concerning human tissue. The aim of this study was to analyze human tissue containing CFR-PEEK as well as UHMWPE wear debris. The authors hypothesized no difference between the used biomaterials. Methods and Materials. In 10 patients during knee revision surgery of a rotating-hinge-knee-implant-design, synovial tissue samples were achieved (tibial inserts: UHMWPE; bushings and flanges: CFR-PEEK). One additional patient received revision surgery without any PEEK components as a control. The tissue was paraffin-embedded, sliced into 2 μm thick sections, and stained with hematoxylin and eosin in a standard process. A modified panoptical staining was also done. Results. A “wear-type” reaction was seen in the testing and the control group. In all samples, the UHMWPE particles were scattered in the tissue or incorporated in giant cells. CFR-PEEK particles were seen as conglomerates and only could be found next to vessels. CFR-PEEK particles showed no giant-cell reactions. In conclusion, the hypothesis has to be rejected. UHMWPE and PEEK showed a different scatter-behavior in human synovial tissue.
AIMUntil now, there has been no consensus as to whether stemmed acetabular components are appropriate for use in patients undergoing revision total hip arthroplasty (THA) who have major acetabular defects or pelvic discontinuity. We wished to address this deficiency in the literature.PATIENTS AND METHODSWe carried out a retrospective study of 35 patients (six men and 29 women) with a mean age of 68 years (37 to 87), with major acetabular defects who underwent revision THA between 2000 and 2012.RESULTSAt a mean follow-up of 63 months (24 to 141), a total of 15 patients (43%) had required at least one further operation. Six implants (17%) loosened aseptically, four (11%) were further revised for infection and two (6%) for technical failure. By taking revision for any reason as the endpoint, the rate of survival of the implant was 61% after five years; by taking revision for aseptic loosening as the end point, it was 78%. The cumulative five-year survival for aseptic loosening was 94% in patients without pelvic discontinuity, and 56% in those with pelvic discontinuity.CONCLUSIONThese results indicate a significantly worse survival in patients with pelvic discontinuity (p = 0.020) and we advise caution in the use of the pedestal component in patients with major acetabular defects and pelvic discontinuity who require revision THA. As a result of these findings we have stopped using this implant and prefer to use particulate bone grafts protected with an anti-protrusion cage and posterior column plate fixation, if necessary.TAKE HOME MESSAGEBased on these poor results, we advise caution if using the pedestal component in patients with major acetabular defects with the presence of a pelvic discontinuity. Cite this article: Bone Joint J 2016;98-B:772-9.
Ten to twenty percent of patients with total knee arthroplasty (TKA) are dissatisfied with their clinical outcome. Aim of this study was to investigate the impact of personality traits on the subjective outcome of TKA. We investigated 80 patients with 86 computer navigated TKAs. We asked for patients satisfaction and divided patients into two groups (satisfied or dissatisfied). 12 personality traits were tested by the Freiburg Personality Inventory (FPI-R). Postoperative examination included Knee Society Score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), and the Visual Analogue Scale (VAS). Radiologic investigation was done in all patients. 84% of our patients were satisfied, while 16% were not satisfied. The FPI-R showed statistical significant influence of four personality traits on patient satisfaction: life satisfaction (p = 0.006), performance orientation (p = 0.015), somatic distress (p = 0.001), and emotional stability (p = 0.002). All clinical scores (VAS, WOMAC, and KSS) showed significantly better results in the satisfied patient. Radiological examination showed optimal alignment of all TKAs. There were no complications requiring revision surgery. The results of our study show that personality traits may influence patients satisfaction and clinical outcome after TKA. Therefore patients personality traits may be a useful predictive factor for postoperative satisfaction after TKA.
BACKGROUND:Second-generation, metal-on-metal bearings were introduced in 1988, to reduce wear and avoid polyethylene particle-induced osteolysis from total hip arthroplasty. In 2007, we reported the long-term results of ninety-eight patients (105 hips) who underwent primary cementless total hip arthroplasty involving the use of a prosthesis with a high-carbide-concentration, metal-on-metal articulating surface between November 1992 and May 1994. The present study gives an update on this patient cohort.METHODS:At a minimum of seventeen years postoperatively, forty-nine patients (fifty-two hips) were available for follow-up examination. We retrospectively evaluated clinical and radiographic results as well as serum metal concentration. The mean patient age at the time of the index arthroplasty was fifty-six years.RESULTS:Three cups (6% of the hips) and one stem (2% of the hips) were revised because of aseptic loosening of the implants combined with focal osteolysis. At the time of the latest follow-up evaluation, the mean Harris hip score was 88.8 points, and the mean University of California Los Angeles (UCLA) activity score was 6.7 points. The cumulative rate of implant survival, with aseptic failure as the end point, was 93.0% at 18.8 years. The median serum cobalt concentration in patients whose hip implant was the only source of cobalt was 0.70 μg/L (range, 0.4 to 5.1 μg/L), showing no increase in the value as noted at a minimum of ten years of follow-up.CONCLUSIONS:The clinical and radiographic results of our study, which, to our knowledge, represent the longest duration of follow-up for a series of cementless total hip arthroplasties with use of a 28-mm metal-on-metal bearing, continue to be comparable with the results observed for other hard-on-hard bearings.
The objective of the present study was to evaluate the biotribological behaviour, in terms of wear and particle release, of bushings and flanges made of carbon fibre reinforced poly-ether-ether-ketone (CFR-PEEK) in articulation with a zirconium nitride (ZrN) multilayer surface coating in a rotating hinge knee system. For the bushings of the rotational and flexion axles and the medial and lateral flanges, a CFR-PEEK with 30% polyacrylonitrile fibre content was used in a new bearing combination with ZrN. In vitro wear simulation was performed for patients with metal ion hypersensitivity, using a new rotating hinge knee design with a ZrN surface articulation in comparison with the clinically established cobalt–chromium version. For the bushings and flanges made of CFR-PEEK subjected to wear simulation, the volumetric wear rates were 2.3 ± 0.48 mm3 million−1 cycles in articulation to cobalt–chromium as reference and 0.21 ± 0.02 mm3 million−1 cycles in the coupling with ZrN, a 10.9-fold decrease. The released CFR-PEEK particles were comparable in size and shape for the coupling to cobalt–chromium and ZrN with most of the particles in a size range between 0.1 and 2 μm. The study reveals comparable low wear and no macroscopic surface fatigue in a new rotating hinge knee design with highly congruent flanges and axles bushings made of CFR-PEEK articulating to a ZrN multilayer surface coating. Favourable wear behaviour of the newly introduced CFR-PEEK/ZrN coupling in comparison with the clinically established CFR-PEEK/cobalt–chromium articulation was found.
In a randomised study, 28 patients with a mean age of 62.2 years (32 to 81) with osteoarthritis or avascular necrosis of the hip received either a ceramic-on-ceramic or a metal-on-metal total hip replacement. Apart from the liners the acetabular and femoral components were made of Ti-Al-Nb alloy. The serum aluminium and cobalt levels were measured before, and at one year after surgery. The 15 patients in the ceramic-on-ceramic group had a median pre-operative aluminium level of 1.3 microg/l (0.25 to 8.4) and a cobalt level below the detection limit. At one year the aluminium level was 1.1 microg/l (0.25 to 2.3) and the cobalt level was 0.4 microg/l (0.15 to 0.7). The 13 patients in the metal-on-metal group had a median pre-operative aluminium level of 1.9 microg/l (0.25 to 4.4) and a cobalt level below the detection limit. At one year the median aluminium level was 0.9 microg/l (0.25 to 3.9) whereas the cobalt level was 1.4 microg/l (0.5 to 10.5). This increase in the cobalt level at one year was significant (p < 0.001). Our findings indicate that ceramic-on-ceramic bearings do not cause elevated levels of serum aluminium in the first post-operative year.
Objective: To investigate the presence of mesenchymal precursor cells (MPCs) in synovial surface projections of patients with osteoarthritis (OA), to characterize their phenotype and to show their localization.Methods: Progenitor cells in synovial surface projections were identified by immunohistochemistry, morphometric analysis and confocal laser scanning microscopy using the following phenotypic markers: STRO-1, CD34, and alpha smooth muscle actin (alpha-SMA).Results: In the synovial tissue of all 21 patients with OA MPCs were detected. Immunohistochemistry and subsequent morphometric analysis showed that approximately twice as many STRO-1(+) cells/mm(2) were observed in synovial tissue of patients with OA as compared to healthy organ donors and that number of STRO-1(+) cells/mm(2) correlated with total cell number/mm(2). Interestingly, in the synovial tissue of patients with OA, twice as many STRO-1(+) cells/mm(2) were found in synovial surface projections as compared to the sublining area without villi. Using confocal laser scanning microscopy two populations of STRO-1(+) MPCs could be detected in synovial surface projections. Single STRO-1(+) cells that co-expressed alpha-SMA resemble a population of pericyte precursors required to stabilize the immature vasculature. The second STRO-1(+) cell population that was found lacked a-SMA but co-expressed CD34 on their surface with low intensity.Conclusion: Here we can show that in the synovial tissue of patients with OA twice as many STRO-1(+) MPCs can be found in synovial surface projections as compared to the sublining area. These cells are preferentially located at the basis and in the protruding end of the synovial surface projection. (C) 2006 OsteoArthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
AIM:Several risk factors are associated with heterotopic bone formation following total hip replacement. All these risk factors were defined in cohorts without any treatment against postoperative ectopic bone. The aim of this prospective study was to reveal risk factors for the development of postoperative ossifications in patients who underwent a 7-day course of indomethacin therapy.METHODS:211 consecutive patients with 217 cementless total hip arthroplasties were included. Patients were given 100 mg indomethacin daily in a 7-day course.RESULTS:Grade 2 or 3 ossifications were observed in 13 (5%) of the male and 3 (2%) of the female Individuals postoperatively (p = 0.0043; odds ratio = 0.45). Older individuals (p = 0.0021; odds ratio = 1.03) as well as patients with primary osteoarthritis (p = 0.0307; odds ratio = 0.28) also showed a higher risk for developing ectopic bone formations.CONCLUSION:With a 7-day course of indomethacin after total hip arthroplasty, male and elderly individuals, as well as patients with primary osteoarthritis, are considered to be at high risk to develop heterotopic ossifications postoperatively. Indomethacin reduces the incidence of postoperative ectopic ossifications, but not the patient's risk.
The purpose was to assess axial alignment of the lower limb using mechanical axis measurements on conventional and digital radiographs. Total-leg radiographs of 24 patients, 8 male and 16 female, with a mean age of 68.6+/-10.2 years, were performed in a standardized anterior-posterior projection and standing position using a conventional and digital phosphor storage film screen radiography system. Knee joint angulation was assessed by measuring the angle between a line drawn from the center of the femoral head to the middle of the femoral condyles and a line drawn from the middle of the tibial condyles to the midpoint of the malleolus. On conventional leg radiographs, line drawing and angle measurement were performed manually with a transparent goniometer. Angle measurement on digital leg radiographs was performed on a PACS workstation using computer-assisted measurement software (IMPAX, AGFA-GEVAERT, Belgium). Evaluation time for both measurements was recorded. We diagnosed 14 varus and 10 valgus angulations of the knee joint. The mean individual difference between axis deviation of conventional digital leg radiographs was 0.93+0.6 degrees (min 0 degrees, max 2 degrees), the mean difference in varus angulation was 1.13+/-0.45 degrees (min 0.3 degrees, max 2 degrees), and the mean difference in valgus angulation was 0.65+/-0.71 degrees (min 0 degrees, max 2 degrees). Angle measurements on conventional and digital radiographs did not show any statistically significant difference. Mean time exposure was 4.9 min/patient for manual and 1.08 min/patient for computer-assisted angle measurement (P<0.001). Computer-assisted angle measurement on digital total-leg radiographs represents a reliable method with no significant angle differences compared to conventional radiographic systems and offers a significantly lower evaluation time.
Aim: This retrospective study aimed at the statistical identification of risk factors for dislocation for a certain cementless hip endoprothesis. Material and method: At our department 2605 primary total hip arthroplasties were performed between 1987 and 1997. In 40 patients (1.5%) a dislocation occurred. These patients were compared with a control group matched in number. Results: No difference was found in both groups with respect to age, height, weight, body-mass index, and diagnosis. A tendency was found that more males were involved in the dislocation group. There were more previous operations found in this group (p = 0.005). Also significant was the fact, that patients in the dislocation group more often had epidural anaesthesia (p = 0.02), more often the implantation of the smaller 28-mm head ( vs. 32 mm) (p = 0.02), and a higher inclination angle of the acetabular component (p = 0.02). No difference was found in terms of the surgeons experience, the postoperative leg length, femoral offset, medialisation, cranialisation and antetorsion of the acetabular component. Conclusion: Dislocation after total hip arthroplasty is a multifactorial complication. With the use of the Alloclassic((R))/Zweymuller total hip endoprthesis, a higher risk for dislocation was found for patients with previous hip surgery, the use of the smaller endoprosthesis head, a high acetabular inclination angle, and in the use of epidural anaesthesia.
This retrospective study aimed at the statistical identification of risk factors for dislocation for a certain cementless hip endoprothesis.At our department 2605 primary total hip arthroplasties were performed between 1987 and 1997. In 40 patients (1.5%) a dislocation occurred. These patients were compared with a control group matched in number.No difference was found in both groups with respect to age, height, weight, body-mass index, and diagnosis. A tendency was found that more males were involved in the dislocation group. There were more previous operations found in this group (p = 0.005). Also significant was the fact, that patients in the dislocation group more often had epidural anaesthesia (p = 0.02), more often the implantation of the smaller 28-mm head (vs. 32 mm) (p = 0.02), and a higher inclination angle of the acetabular component (p = 0.02). No difference was found in terms of the surgeons experience, the postoperative leg length, femoral offset, medialisation, cranialisation and antetorsion of the acetabular component.Dislocation after total hip arthroplasty is a multifactorial complication. With the use of the Alloclassic/Zweymüller total hip endoprothesis, a higher risk for dislocation was found for patients with previous hip surgery, the use of the smaller endoprosthesis head, a high acetabular inclination angle, and in the use of epidural anaesthesia.
AIM:This retrospective study aimed at the statistical identification of risk factors for dislocation for a certain cementless hip endoprothesis.MATERIAL AND METHOD:At our department 2605 primary total hip arthroplasties were performed between 1987 and 1997. In 40 patients (1.5%) a dislocation occurred. These patients were compared with a control group matched in number.RESULTS:No difference was found in both groups with respect to age, height, weight, body-mass index, and diagnosis. A tendency was found that more males were involved in the dislocation group. There were more previous operations found in this group (p = 0.005). Also significant was the fact, that patients in the dislocation group more often had epidural anaesthesia (p = 0.02), more often the implantation of the smaller 28-mm head (vs. 32 mm) (p = 0.02), and a higher inclination angle of the acetabular component (p = 0.02). No difference was found in terms of the surgeons experience, the postoperative leg length, femoral offset, medialisation, cranialisation and antetorsion of the acetabular component.CONCLUSION:Dislocation after total hip arthroplasty is a multifactorial complication. With the use of the Alloclassic/Zweymüller total hip endoprothesis, a higher risk for dislocation was found for patients with previous hip surgery, the use of the smaller endoprosthesis head, a high acetabular inclination angle, and in the use of epidural anaesthesia.
An Achilles tendon allograft with its bony insertion was used to bridge a Titanium implant, containing an endoprosthetic tendon anchor, and the sheep biceps muscle, Twelve sheep were operated on unilaterally and followed up clinically and histologically for 2, 4 (n = 2), 8, and 12 months (n = 4), Full function of the front limb was regained after 8 to 12 weeks, There were no signs of mechanical loosening at all times. The morphologic changes at the bone block and implant fixation site were an initial revascularization of the allograft bone, which was observed at 2 months and enhanced at 4 months but occurred without any evidence of bone remodeling, This was changed in all specimens taken at 8 and 12 months where intensive new bone development, remodeling, and bone ingrowth in the titanium implant was found. Bone mass was shifted significantly to the tendon insertion half of the bone block because of a creeping substitution of the cancellous allograft bone and bone ingrowth to the implant. Overall bone mass slightly decreased with time but resorption of allograft bone outweighed new bone development only at lesser loaded areas. Transplantation of a bone and tendon allograft to an implant resulted in a revitalized, mechanically stable, and biologically anchored compound.
We compared two methods of reconstruction of the abductor mechanism in 15 patients after prosthetic replacement of the upper femur, to assess abductor strength and function. Six patients in group I had direct fixation of the gluteus medius tendon and a segment of the original bone to the prosthesis. Nine patients in group 2 had the abductor tendon fixed to the iliotibial band. We assessed clinical function, isometric muscle strength and muscle cross-sectional area for each patient. The patients in group 1 had better clinical and functional results (p = 0.059), with average peak torques for hip abduction of 92% of that in the non-operated leg in group 1, and of 57% in group 2. Group 1 had a mean muscle cross-sectional area of 69% and a mean value of strength per cross-sectional area of 134% when compared with the control side. The respective values for group 2 were 52% and 91%. Direct fixation of the abductor muscles to the prostheses gave improved function and higher isometric abductor muscle force.