Manganese pollution in water has severe toxic effects on biological organisms, including humans. Early detection is crucial to apply timely corrective measures and prevent irreversible consequences. Standard monitoring methods are expensive, time-consuming, and difficult to implement in resource-limited settings, leading to inefficient pollution remediation. The low cost and small size of screen-printed electrodes make them well-suited for on-site analysis but require flow conditions for sensitive results, making them difficult to implement in real-world scenarios. To address this challenge, we present the use of paper microfluidics in combination with screen-printed carbon electrodes for the electrochemical detection of manganese in water. Capillary-driven flow using paper microfluidics provided a practical fluid delivery method for on-site electroanalysis, which was compared to conventional flow methods, i.e., batch setups and flow cells, to demonstrate fitness for purpose. The sensing platform showed a linear response to Mn-(II) up to 200 μg L-1, with a detection limit of 0.69 μg L-1, well below the WHO guideline value. The response of the sensor was also analyzed in the presence of potentially interfering metals, and validated in real samples, showing excellent agreement with a standard inductively coupled plasma optical emission spectroscopy method. This approach, inducing flow with paper, is more sustainable, simple, portable, and cost-effective compared to the conventional methods, resulting in a setup with high applicability toward the detection of other pollutants such as metals, PFAS, and pharmaceuticals.
Urinary tract infections (UTIs) represent the most prevalent type of outpatient infection, with significant adverse health and economic burdens. Current culture-based antibiotic susceptibility testing can take up to 72 h resulting in ineffective prescription of broad-spectrum antibiotics, poor clinical outcomes and development of further antibiotic resistance. We report an electrochemical lab-on-a-chip (LOC) for testing samples against seven clinically-relevant antibiotics. The LOC contained eight chambers, each housing an antibiotic-loaded hydrogel (cephalexin, ceftriaxone, colistin, gentamicin, piperacillin, trimethoprim, vancomycin) or antibiotic-free control, alongside a resazurin bulk-modified screen-printed electrode for electrochemical detection of metabolically active bacteria using differential pulse voltammetry. Antibiotic susceptibility in simulated UTI samples or donated human urine with either Escherichia coli or Klebsiella pneumoniae could be established within 85 min. Incorporating electrochemical detection onto a LOC provides an inexpensive, simple method for the sensitive determination of antibiotic susceptibility that is significantly faster than using a culture-based approach.
Agroathelia rolfsii (A. rolfsii) is a fungal infection and poses a significant threat to over 500 plant species worldwide. It can reduce crop yields drastically resulting in substantial economic losses. While conventional detection methods like PCR offer high sensitivity and specificity, they require specialized and expensive equipment, limiting their applicability in resource-limited settings and in the field. Herein, we present an integrated workflow with nucleic acid extraction and isothermal amplification in a lab-on-a-chip cartridge based on immiscible filtration assisted by surface tension (IFAST) to detect A. rolfsii fungi in soil for point-of-need application. Our approach enabled both DNA extraction of A. rolfsii from soil and subsequent colorimetric loop-mediated isothermal amplification (LAMP) to be completed on a single chip, termed IFAST-LAMP. LAMP primers targeting ITS region of A. rolfsii were newly designed and tested. Two DNA extraction methods based on silica paramagnetic particles (PMPs) and three LAMP assays were compared. The best-performing assay was selected for on-chip extraction and detection of A. rolfsii from soil samples inoculated with concentrations of 3.75, 0.375 and 0.0375 mg fresh weight per 100-gram soil (%FW). The full on-chip workflow was achieved within a one-hour turnaround time. The platform was capable of detecting as low as 3.75 %FW at 2 days after inoculation and down to 0.0375 %FW at 3 days after inoculation. The IFAST-LAMP could be suitable for field-applicability for A. rolfsii detection in low-resource settings.
There is a growing need for easy-to-use, low cost and portable quantitative assays to determine active pharmaceutical ingredients in the pharmaceutical industry. Here, we developed a batch spectrophotometric method and a method employing a paper-based microfluidic device for the estimation of Amoxicillin (AMX) in pure solution and pharmaceutical preparations. The detection depends on the coupling reaction of Amoxicillin with diazotized sulfadimidine (DSDM) in an alkaline medium. The yellow azo dye reaction product was measured at λmax 425 nm and linearity was observed from 2 to 30 mg L−1 with a detection limit of 0.32 mg L−1 and a quantification limit of 1.2 mg L−1 was found. The reaction was then transferred onto the paper-based microfluidic device and a plateau change in color intensity was found above 10 mg L−1. Thus, the paper-based microfluidic device can be applied for the semi-quantitative determination of Amoxicillin in pure solution and commercial pharmaceutical products for rapid screening.
Solid tumours are complex and heterogeneous systems, which exist in a dynamic biophysical microenvironment. Conventional cancer research methods have long relied on two-dimensional (2D) static cultures which neglect the dynamic, three-dimensional (3D) nature of the biophysical tumour microenvironment (TME), especially the role and impact of interstitial fluid flow (IFF). To address this, we undertook a transcriptome-wide analysis of the impact of IFF-like perfusion flow using a spheroid-on-chip microfluidic platform, which allows 3D cancer spheroids to be integrated into extracellular matrices (ECM)-like hydrogels and exposed to continuous perfusion, to mimic IFF in the TME. Importantly, we have performed these studies both in experimental (normoxia) and pathophysiological (hypoxia) oxygen conditions. Our data indicated that gene expression was altered by flow when compared to static conditions, and for the first time showed that these gene expression patterns differed in different oxygen tensions, reflecting a differential role of spheroid perfusion in IFF-like flow in tumour-relevant hypoxic conditions in the biophysical TME. We were also able to identify factors primarily linked with IFF-like conditions which are linked with prognostic value in cancer patients and therefore could correspond to a potential novel biomarker of IFF in cancer. This study therefore highlights the need to consider relevant oxygen conditions when studying the impact of flow in cancer biology, as well as demonstrating the potential of microfluidic models of flow to identify IFF-relevant tumour biomarkers.
Glioblastoma (GBM) is a deadly disease with a poor prognosis, there is therefore a crucial need for novel therapeutic targets. Current preclinical models of GBM fail to predict clinical outcomes, thus, new translationally relevant models are urgently needed for reliable therapeutic target validation. 3D spheroid culture of cancer cells has been shown to better reflect tumour biology than 2D monolayer culture, as has culturing cells in flow-based microfluidic devices, which mimic key aspects of the tumour microenvironment. Gene knockdown by siRNA is a key preclinical target validation tool, however, siRNA-mediated knockdown of cancer spheroids in microfluidic culture has not yet been demonstrated. Here we describe a simple and robust microfluidic device that can maintain GBM spheroids (U87 cells) for at least 7 days. Via RNA sequencing analysis, we demonstrate that spheroids grown in microfluidic culture are more proliferative than spheroids grown in static plate culture and downregulate genes associated with cell adhesion, potentially offering insights into the metastatic process. Comparison of target gene (PRMT2 and RAB21) knockdown using siRNA between 2D monolayer cultured cells, static spheroid culture and spheroids maintained in the microfluidic device showed that gene expression (as measured by quantitative-PCR) was significantly reduced in all culture systems. Knockdown was most efficient in cells grown in 2D monolayer culture followed by static spheroid culture, but we also demonstrate [Formula: see text] knockdown efficiency using the microfluidic device. In summary, this study describes an easy-to-use microfluidic culture platform and provides evidence that pre-clinical siRNA-mediated target validation studies will be possible in flow systems that mimic tumour physiology.
Abstract AIMS • Assess/evaluate transcriptomic changes in GBM, maintained on a microfluidics system, in response to treatment with arginine methylation inhibitor GSK3368715, currently in clinical trials, to identify novel therapeutic strategies, synergising with personalised patient care and precision medicine • Investigate molecular differences between healthy brain and GBM maintained on-chip in response to GSK3368715, including proliferation, apoptosis and splicing. METHOD GBM biopsies from Hull Royal Infirmary, or healthy mouse brain tissues, were maintained on-chip for 8- days and perfused with GSK3368715-treated media, at 3 μl/min, mimicking the in vivo environment. RNA- sequencing determined thousands of differentially expressed genes and alternative splicing (AS) events resulting from GSK3368715 treatment. Immunohistochemistry displayed the effect of GSK3368715 on healthy mouse brain tissue to ascertain the specificity of the arginine methylation inhibitor in leading to GBM apoptosis. RESULTS RNA-sequencing showed highly significant GO-term-enrichment in ribosome and translation pathways, suggesting decreased protein synthesis capacity after GSK3368715 treatment. Additionally, several hundreds of genes were found to be undergoing AS, compatible with a mechanism where changes in the arginine methylation pattern of spliceosome member FUS, upon GSK3368715 treatment, contribute to AS. Of these events, 136 (more than expected by chance, χ2 = 7.16, p = 0.007) were known FUS splicing targets. GO-term-enrichment of these AS events was found in DNA damage and cell death . Together these results are consistent with immunohistological findings that GSK3368715 causes apoptosis in GBM-on-chip tissue, in a specific manner. CONCLUSIONS Our results highlight an exciting potential therapeutic target for GBM, via induction of alternative splicing path- ways, through arginine methylation inhibition with GSK3368715.
Despite the large number of microfluidic devices that have been described over the past decade for the study of tissues and organs, few have become widely adopted. There are many reasons for this lack of adoption, primarily that devices are constructed for a single purpose or because they are highly complex and require relatively expensive investment in facilities and training. Here, we describe a microphysiological system (MPS) that is simple to use and provides fluid channels above and below cells, or tissue biopsies, maintained on a disposable, poly(methyl methacrylate), carrier held between polycarbonate outer plates. All other fittings are standard Luer sizes for ease of adoption. The carrier can be coated with cells on both sides to generate membrane barriers, and the devices can be established in series to allow medium to flow from one cell layer to another. Furthermore, the carrier containing cells can be easily removed after treatment on the device and the cells can be visualized or recovered for additional off-chip analysis. A 0.4 μm membrane with cell monolayers proved most effective in maintaining separate fluid flows, allowing apical and basal surfaces to be perfused independently. A panel of different cell lines (Caco-2, HT29-MTX-E12, SH-SY5Y, and HUVEC) were successfully maintained in the MPS for up to 7 days, either alone or on devices connected in series. The presence of tight junctions and mucin was expressed as expected by Caco-2 and HT-29-MTX-E12, with Concanavalin A showing uniform staining. Addition of Annexin V and PI showed viability of these cells to be >80% at 7 days. Bacterial extracellular vesicles (BEVs) produced by Bacteroides thetaiotaomicron and labeled with 1,1′-dioctadecyl-3,3,3′,3′-tetramethylindocarbo-cyanine perchlorate (DiD) were used as a model component of the human colonic microbiota and were visualized translocating from an apical surface containing Caco-2 cells to differentiated SH-SY5Y neuronal cells cultured on the basal surface of connected devices. The newly described MPS can be easily adapted, by changing the carrier to maintain spheroids, pieces, or slices of biopsy tissue and joined in series to study a variety of cell and tissue processes. The cell layers can be made more complex through the addition of multiple cell types and/or different patterning of extracellular matrix and the ability to culture cells adjacent to one another to allow study of cell:cell transfer, e.g., passive or active drug transfer, virus or bacterial entry or BEV uptake and transfer.
Gonorrhea is the second most common sexually transmitted infection (STI) with around 87 million cases worldwide estimated in 2016 by the World Health Organization. With over half of the cases being asymptomatic, potential life-threatening complications and increasing numbers of drug-resistant strains, routine monitoring of prevalence and incidence of infections are key preventive measures. Whilst gold standard qPCR tests have excellent accuracy, they are neither affordable nor accessible in low-resource settings. In this study, we developed a lab-on-a-chip platform based on microscale immiscible filtration to extract, concentrate and purify Neisseria gonorrhoeae DNA with an integrated detection assay based on colorimetric isothermal amplification. The platform was capable of detecting as low as 500 copies/mL from spiked synthetic urine and showed no cross-reactivity when challenged with DNAs from other common STIs. The credit card–size device allows DNA extraction and purification without power or centrifuges, and the detection reaction only needs a low-tech block heater, providing a straightforward and visual positive/negative result within 1 h. These advantages offer great potential for accurate, affordable and accessible monitoring of gonorrhea infection in resource-poor settings.
Arginine methylation is a post-translational modification that consists of the transfer of one or two methyl (CH3) groups to arginine residues in proteins. Several types of arginine methylation occur, namely monomethylation, symmetric dimethylation and asymmetric dimethylation, which are catalysed by different protein arginine methyltransferases (PRMTs). Inhibitors of PRMTs have recently entered clinical trials to target several types of cancer, including gliomas (NCT04089449). People with glioblastoma (GBM), the most aggressive form of brain tumour, are among those with the poorest quality of life and likelihood of survival of anyone diagnosed with cancer. There is currently a lack of (pre)clinical research on the possible application of PRMT inhibitors to target brain tumours. Here, we set out to investigate the effects of clinically-relevant PRMT inhibitors on GBM biopsies. We present a new, low-cost, easy to fabricate perfusion device that can maintain GBM tissue in a viable condition for at least eight days post-surgical resection. The miniaturised perfusion device enables the treatment of GBM tissue with PRMT inhibitors ex vivo, and we observed a two-fold increase in apoptosis in treated samples compared to parallel control experiments. Mechanistically, we show thousands of differentially expressed genes after treatment, and changes in the type of arginine methylation of the RNA binding protein FUS that are consistent with hundreds of differential gene splicing events. This is the first time that cross-talk between different types of arginine methylation has been observed in clinical samples after treatment with PRMT inhibitors.
Bioanalytical processes such as ligand-binding assays, nucleic acid amplification tests and cancer cell identification methods require multiple steps including sampling, transport, sample preparation, chemical reaction/s, detection and interpretation. These necessitate trained personnel and laboratory infrastructure, and are often time-consuming and labor-intensive. Integrated platforms capable of combining the aforementioned steps are generally challenging to realize. Approaches employing immiscible phases constrained in the microscale and paramagnetic particles have emerged as pathways to extract proteins, nucleic acids and whole cells from complex matrices via affinity purification and magnetic actuation. In recent years, further steps for detection and readout of these bioanalytes have been incorporated, providing versatile lab-on-a-chip platforms for multiple integrated bioanalytical workflows and with great potential as point-of-need devices. In this manuscript, we review and summarize the different strategies employed and lay out further avenues for development and implementation.
Porous polymeric microspheres are an emerging class of materials, offering stimuli-responsive cargo uptake and release. Herein, we describe a new approach to fabricate porous anisotropic microspheres based on temperature-induced droplet formation and light-induced polymerisation. Anisotropic liquid crystal (LC) microparticles were prepared by exploiting the partial miscibility of a thermotropic LC mixture composed of 4-cyano-4’- pentylbiphenyl (5CB, unreactive mesogens) with 2-methyl- 1,4-phenylene bis4-[3-(acryloyloxy)propoxy] benzoate (RM257, reactive mesogens) in methanol (MeOH). Isotropic 5CB/RM257-rich droplets were generated by cooling below the binodal curve (20°C), and the isotropic-to-nematic transition occurred after cooling below 0°C. The resulting 5CB/RM257-rich droplets with radial configuration were subsequently polymerised under UV light, resulting in nematic microparticles. Upon heating the mixture, the 5CB mesogens underwent a nematic-isotropic transition and eventually became homogeneous with MeOH, while the polymerised RM257 preserved its radial configuration. Repeated cycles of cooling and heating resulted in swelling and shrinking of the porous microparticles. The use of a reversible materials templating approach to obtain porous microparticles provides new insights into binary liquid manipulation and potential for microparticle production.
Abstract AIMS Assess/evaluate apoptosis in GBM samples maintained on a microfluidics system in response to GSK3368715 and other PRMT inhibitors, currently in clinical trials, with the ultimate goal of synergising with personalised patient care and precision medicine. Investigate the effect of treating GBM biopsies on-chip with PRMT inhibitors at the molecular level, including RNA and protein modifications. METHOD GBM biopsies are received from Hull Royal Infirmary and maintained on-chip for 8-days. They are perfused with media, at a rate of 3 μl/min, mimicking the in vivo environment and allowing real-time analysis of tumour behaviour. PRMT inhibitors, such as GSK3368715, are added to the media, in conjunction with TMZ, to determine their efficacy ex vivo using a range of techniques, such as: immunohistochemistry, cell viability assays, protein analysis and RNA-sequencing. RESULTS We show that PRMT inhibition increases apoptosis five-fold above the control, untreated GBM-on-chip samples. This is compounded by cell viability assays, which have indicated that cell viability in these post-chip tissues is reduced by 30% upon treatment with 1μM GSK3368715. Additionally, western blot analysis has indicated that PRMT inhibition with GSK3368715 appears to switch the methylation status of fused-in-sarcoma (FUS) protein in GBM biopsies. CONCLUSION These results indicate that PRMT inhibition may not only be a viable target for GBM therapy, but could also highlight a mechanism for re-sensitising MGMT-negative GBM to TMZ. This data produces an exciting argument for further research into the use of this novel inhibitor for improving prognosis for patients diagnosed with this devastating disease.
In response to the ongoing COVID-19 pandemic and disparities of vaccination coverage in low-and middle-income countries, it is vital to adopt a widespread testing and screening programme, combined with contact tracing, to monitor and effectively control the infection dispersion in areas where medical resources are limited. This work presents a lab-on-a-chip platform, namely IFAST-CRISPR, as an affordable, rapid and high-precision molecular diagnostic means for SARS-CoV-2 detection. The herein proposed sample-to-answer platform integrates RNA extraction, amplification and CRISPR-Cas-based detection with lateral flow readout in one device. The microscale dimensions of the device containing immiscible liquids, coupled with the use of silica paramagnetic beads and GuHCl, streamline sample preparation, including RNA concentration, extraction and purification, in 15 min with minimal hands-on steps. By combining RT-LAMP with CRISPR-Cas12 assays targeting the nucleoprotein (N) gene, visual identification of [≥] 470 copies mL-1 genomic SARS-CoV-2 samples was achieved in 45 min, with no cross-reactivity towards HCoV-OC43 nor H1N1. On-chip assays showed the ability to isolate and detect SARS-CoV-2 from 1,000 genome copies mL-1 of replication-deficient viral particles in 1 h. This simple, affordable and integrated platform demonstrated a visual, faster, and yet specificity and sensitivity-comparable alternative to the costly gold-standard RT-PCR assay, requiring only a simple heating source. Further investigations on multiplexing and direct interfacing of the accessible Swan-brand cigarette filter for saliva sample collection could provide a complete work flow for COVID-19 diagnostics from saliva samples suitable for low-resource settings.
In response to the ongoing coronavirus disease 2019 (COVID-19) pandemic and disparities of vaccination coverage in low-and middle-income countries, it is vital to adopt a widespread testing and screening programme, combined with contact tracing, to monitor and effectively control the infection dispersion in areas where medical resources are limited. This work presents a lab-on-a-chip device, namely 'IFAST-LAMP-CRISPR', as an affordable, rapid and high-precision molecular diagnostic means for detection of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2). The herein proposed 'sample-to-answer' platform integrates RNA extraction, amplification and molecular detection with lateral flow readout in one device. The microscale dimensions of the device containing immiscible liquids, coupled with the use of silica paramagnetic beads and guanidine hydrochloride, streamline sample preparation (including RNA extraction, concentration and purification) in 15 min with minimal hands-on steps. The pre-amplification in combination with CRISPR-Cas12a detection assays targeting the nucleoprotein (N) gene achieved visual identification of ≥ 470 copies mL-1 genomic SARS-CoV-2 samples in 45 min. On-chip assays showed the ability to isolate and detect SARS-CoV-2 RNA from 100 genome copies mL-1 of replication-deficient viral particles in 1 h. This simple, affordable and integrated platform demonstrated a visual, faster, and yet specificity- and sensitivity-comparable alternative to the costly gold-standard reverse transcription-polymerase chain reaction (RT-PCR) assay, requiring only a simple heating source. Initial testing illustrates the platform viability both on nasopharyngeal swab and saliva samples collected using the easily accessible Swan-brand cigarette filter, providing a complete workflow for COVID-19 diagnostics in low-resource settings.
Failure of conventional water treatment systems may lead to the contamination of water sources, which can cause outbreaks of waterborne healthcare associated infections. Advanced oxidation processing by non-thermal plasma has the potential to treat water without the addition of chemicals. Antibiotic resistant Pseudomonas aeruginosa and Escherichia coli were chosen to investigate the use of non-thermal plasma generated in a microfluidic reactor to disinfect bacteria contaminated water. The microfluidic reactor used in this study utilized a dielectric barrier discharge, in a gas-liquid phase annular flow regime. Microbiological analysis of water inoculated with P. aeruginosa and E. coli was carried out before and after plasma treatment. Using air as the carrier gas, effective disinfection of water was achieved. At the lowest flow rate (35 µL/min), P. aeruginosa and E. coli viability were drastically reduced, with an approximate 8 log maximum decrease in viability following an estimated residence time of 5 s of plasma treatment. Scanning electron microscopy indicated changes in cell morphology due to the plasma treatment. Live/Dead assays revealed that the membranes of the cells had been damaged after plasma treatment. This work demonstrated that non-thermal plasma has the potential to disinfect against microbial contamination in water.
We demonstrate how a combination of paper microfluidic devices and handheld mobile technology can be used by citizen scientists to carry out a sustained water monitoring campaign. We have developed a paper-based analysis device and a 3 minute sampling workflow that requires no more than a container, a test device and a smartphone app. The contaminant measured in these pilots are phosphates, detectable down to 3 mg L -1 . Together these allow volunteers to successfully carry out cost-effective, high frequency, phosphate monitoring over an extended geographies and periods.
Monitoring water quality traditionally involves experts collecting samples for laboratory-based analysis; a time consuming, costly process.1 It has been recognised that frequent measurements are needed to understand patterns and pressures of changing contaminant concentrations.2 One approach empowers citizens with simple tools, enabling them to monitor water quality regularly.3 Generally, citizen-led sampling has involved volunteers collecting samples for later analysis by experts. We describe an approach comprising of a series of paper-based sensors, that when coupled with a smartphone, enable citizens to participate in simultaneous collection of samples and generation of onsite measurements. We developed paper microfluidic analytical devices (PADs) for the detection of contaminants (nutrients, metals, organics). All devices were designed to be simple to use with rapid colour readout achieved with minimal user input. Filter paper was patterned with hydrophobic wax barriers to create reaction zones. Within these zones, chemical reagents were stored, that would, upon sample addition, change colour proportionally to the analyte concentration. After addition and drying of reagents, devices were sealed by lamination with a hole cut to allow for sample entry. For water analysis, the devices were placed directly onto the water sample and incubated for a short time (< 10 min). The coloured reaction products were visible to the naked eye; more precise quantification was achieved by capturing a digital image followed by colour intensity analysis. We adapted spectroscopic determination chemistry, so that it was suitable for use on a portable paper platform; successfully developing separate devices for phosphate (LOD 3 mg L-1), copper (LOD 2 mg L-1), chromium (LOD 0.5 mg L-1), nickel (LOD 3 mg L-1), and triclosan (LOD 3 mg L-1). To detect very low concentrations (>µg L-1) of contaminants (metals, organics) usually found in the environment, we aim to combine the simple paper-based readout with an in-field pre-concentration step. By incorporating an electrospun membrane with a simple filtration system, adsorption of copper ions on the membrane surface was demonstrated. Coupling such a pre-concentration method with colour-generating paper readout devices, would potentially provide a simple means for on-site monitoring at environmentally relevant levels. Citizen-led sampling was undertaken to monitor phosphates in freshwater across the Humber region (UK), Belgium, Germany and the Netherlands. Devices featured six reaction zones, two control zones and internal calibration (coloured squares). Results were captured using a custom-developed app, RiverDIP (Natural Apptitude) that also recorded location, turbidity (photos), GPS, date, time and waterbody. Submitted data were analysed, and subsequently plotted on an online map, allowing volunteers to see all sampling efforts with > 300 results returned so far. Engagement with volunteers was investigated to empower people by informing them of sources of domestic pollution. In summary, we have developed a series of simple-to-use paper-based devices to detect water contaminants and demonstrated the feasibility of citizen-led sampling to monitor water quality. Future work will involve further development towards a system for simple onsite pre-concentration and monitoring of heavy metals involving volunteers in the sampling process. * 1.J. Environ. Manage.,87 2008, 639-648. * 2.Sens., 5, 2005, 4-37. * 3.Front. Ecol. Environ.,10, 2012, 298-304.
Contamination of waterways is of increasing concern, with recent studies demonstrating elevated levels of antibiotics, antidepressants, household, agricultural and industrial chemicals in freshwater systems. Thus, there is a growing demand for methods to rapidly and conveniently monitor contaminants in waterways. Here we demonstrate how a combination of paper microfluidic devices and handheld mobile technology can be used by citizen scientists to carry out a sustained water monitoring campaign. We have developed a paper-based analytical device and a 3 minute sampling workflow that requires no more than a container, a test device and a smartphone app. The contaminant measured in these pilots are phosphates, detectable down to 3 mg L-1. Together these allow volunteers to successfully carry out cost-effective, high frequency, phosphate monitoring over an extended geographies and periods.
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused the unprecedented global pandemic of coronavirus disease-2019 (COVID-19). Efforts are needed to develop rapid and accurate diagnostic tools for extensive testing, allowing for effective containment of the infection via timely identification and isolation of SARS-CoV-2 carriers. Current gold standard nucleic acid tests require many separate steps that need trained personnel to operate specialist instrumentation in laboratory environments, hampering turnaround time and test accessibility, especially in low-resource settings. We devised an integrated on-chip platform coupling RNA extraction based on immiscible filtration assisted by surface tension (IFAST), with RNA amplification and detection via colorimetric reverse-transcription loop mediated isothermal amplification (RT-LAMP), using two sets of primers targeting open reading frame 1a (ORF1a) and nucleoprotein (N) genes of SARS-CoV-2. Results were identified visually, with a colour change from pink to yellow indicating positive amplification, and further confirmed by DNA gel electrophoresis. The specificity of the assay was tested against HCoV-OC43 and H1N1 RNAs. The assay based on use of gene N primers was 100% specific to SARS-CoV-2 with no cross-reactivity to HCoV-OC43 nor H1N1. Proof-of-concept studies on water and artificial sputum containing genomic SARS-CoV-2 RNA showed our IFAST RT-LAMP device to be capable of extracting and detecting 470 SARS-CoV-2 copies mL-1 within 1 h (from sample-in to answer-out). IFAST RT-LAMP is a simple-to-use, integrated, rapid and