Single-molecule Förster Resonance Energy Transfer (smFRET) is utilized to study the structure and dynamics of many bio-molecules, such as proteins, DNA and their various complexes. The structural assessment is based on the well-known Förster relationship between the measured efficiency of energy transfer between a donor (D) and an acceptor (A) dye and the distance between them. Classical smFRET analysis methods called photon distribution analysis (PDA) take into account photon shot-noise, D-A distance distribution and, more recently, interconversion between states in order to extract accurate distance information. It is known that rapid D-A distance fluctuations on the order of the D lifetime (or shorter) can increase the measured mean FRET efficiency and thus decrease the estimated D-A distance. Nonetheless, this effect has been so far neglected in smFRET experiments, potentially leading to biases in estimated distances. Here we introduce a PDA approach dubbed Monte-Carlo-diffusion-enhanced photon inference (MC-DEPI). MC-DEPI recolor detected photons of smFRET experiments taking into account dynamics of D-A distance fluctuations, multiple interconverting states and photo-blinking. Using this approach, we show how different underlying conditions may yield identical FRET histograms and how the additional information from fluorescence decays helps distinguishing between the different conditions. We also introduce a machine learning fitting approach for retrieving the D-A distance distribution, decoupled from the above-mentioned effects. We show that distance interpretation of smFRET experiments of even the simplest dsDNA is nontrivial and requires decoupling the effects of rapid D-A distance fluctuations on FRET in order to avoid systematic biases in the estimation of the D-A distance distribution.
Single-molecule FRET (smFRET) has become a mainstream technique for studying biomolecular structural dynamics. The rapid and wide adoption of smFRET experiments by an ever-increasing number of groups has generated significant progress in sample preparation, measurement procedures, data analysis, algorithms and documentation. Several labs that employ smFRET approaches have joined forces to inform the smFRET community about streamlining how to perform experiments and analyze results for obtaining quantitative information on biomolecular structure and dynamics. The recent efforts include blind tests to assess the accuracy and the precision of smFRET experiments among different labs using various procedures. These multi-lab studies have led to the development of smFRET procedures and documentation, which are important when submitting entries into the archiving system for integrative structure models, PDB-Dev. This position paper describes the current ‘state of the art’ from different perspectives, points to unresolved methodological issues for quantitative structural studies, provides a set of ‘soft recommendations’ about which an emerging consensus exists, and lists openly available resources for newcomers and seasoned practitioners. To make further progress, we strongly encourage ‘open science’ practices.
Single-molecule Förster resonance energy transfer (smFRET) has become a mainstream technique for probing biomolecular structural dynamics. The rapid and wide adoption of the technique by an ever-increasing number of groups has generated many improvements and variations in the technique itself, in methods for sample preparation and characterization, in analysis of the data from such experiments, and in analysis codes and algorithms. Recently, several labs that employ smFRET have joined forces to try to bring the smFRET community together in adopting a consensus on how to perform experiments and analyze results for achieving quantitative structural information. These recent efforts include multi-lab blind-tests to assess the accuracy and precision of smFRET between different labs using different procedures, the formal assembly of the FRET community and development of smFRET procedures to be considered for entries in the wwPDB. Here we delve into the different approaches and viewpoints in the field. This position paper describes the current "state-of-the field", points to unresolved methodological issues for quantitative structural studies, provides a set of 'soft recommendations' about which an emerging consensus exists, and a list of resources that are openly available. To make further progress, we strongly encourage 'open science' practices. We hope that this position paper will provide a roadmap for newcomers to the field, as well as a reference for seasoned practitioners.
Example data files in different formats that can be converted to Photon-HDF5 format using phconvert.
Single-molecule Förster resonance energy transfer (smFRET) is a powerful technique for nanometer-scale studies of single molecules. Solution-based smFRET, in particular, can be used to study equilibrium intra- and intermolecular conformations, binding/unbinding events and conformational changes under biologically relevant conditions without ensemble averaging. However, single-spot smFRET measurements in solution are slow. Here, we detail a high-throughput smFRET approach that extends the traditional single-spot confocal geometry to a multispot one. The excitation spots are optically conjugated to two custom silicon single photon avalanche diode (SPAD) arrays. Two-color excitation is implemented using a periodic acceptor excitation (PAX), allowing distinguishing between singly- and doubly-labeled molecules. We demonstrate the ability of this setup to rapidly and accurately determine FRET efficiencies and population stoichiometries by pooling the data collected independently from the multiple spots. We also show how the high throughput of this approach can be used to increase the temporal resolution of single-molecule FRET population characterization from minutes to seconds. Combined with microfluidics, this high-throughput approach will enable simple real-time kinetic studies as well as powerful molecular screening applications.
Single-molecule FRET (smFRET) allows measuring distances between donor and acceptor fluorophores on the 3-10 nm range. Solution-based smFRET allows measurement of binding-unbinding events or conformational changes of dye-labeled biomolecules without ensemble averaging and free from surface perturbations. When employing dual (or multi) laser exci-tation, smFRET allows resolving the number of fluorescent labels on each molecule, greatly enhancing the ability to study heterogeneous samples. A major drawback to solution-based smFRET is the low throughput, which renders repetitive measurements expensive and hin-ders the ability to study kinetic phenomena in real-time. Here we demonstrate a high-throughput smFRET system which multiplexes acquisition by using 48 excitation spots and two 48-pixel SPAD array detectors. The system employs two excitation lasers allowing separation of species with one or two active fluorophores. The performance of the system is demonstrated on a set of doubly-labeled double-stranded DNA oligonucleotides with different distances between donor and acceptor dyes along the DNA duplex. We show that the acquisition time for accurate subpopulation identification is reduced from several minutes to seconds, opening the way to high-throughput screening applications and real-time kinetics studies of enzymatic reactions such as DNA transcription by bacterial RNA polymerase.
Single-molecule fluorescence resonant energy transfer (smFRET) allows identifying sub-populations within doubly-labeled molecules, based on the distances between the donor (D) and acceptor (A) fluorescent labels. Solution-based smFRET allows measurement of binding-unbinding events or conformational changes of dye-labeled biomolecules without ensemble averaging and free from surface perturbations. When employing dual (or multi) laser excitation, smFRET allows resolving the number of fluorescent labels on each molecule, greatly enhancing the ability to study heterogeneous samples. A major drawback to solution-based smFRET techniques is their low throughput, which renders measurements time-consuming and prevents from studying kinetic phenomena in real-time. Here we demonstrate a high-throughput smFRET setup which multiplexes acquisition by using 48 excitation spots and two 48-pixel single-photon avalanche diode (SPAD) arrays. Using two excitation lasers, one of which is alternated on the 10 us time scale, allows identifying and sorting species with one or two active fluorophores, extending the range of measurable FRET efficiencies and enabling proper fluorescence-aided molecular sorting. The performance of the system is demonstrated with a set of doubly-labeled double-stranded DNA oligonucleotides with different D-A distances. We show that the acquisition time for accurate subpopulation identification is reduced from several minutes to seconds, opening the way to high-throughput screening applications and real-time kinetics studies of enzymatic reactions.
Classical structural biology can only provide static snapshots of biomacromolecules. Single-molecule Förster resonance energy transfer (smFRET) paved the way for studying dynamics in macromolecular structures under biologically relevant conditions. Since its first implementation in 1996, smFRET experiments have confirmed previously hypothesized mechanisms and provided new insights into many fundamental biological processes, such as DNA maintenance and repair, transcription, translation, and membrane transport. We review 22 years of contributions of smFRET to our understanding of basic mechanisms in biochemistry, molecular biology, and structural biology. Additionally, building on current state-of-the-art implementations of smFRET, we highlight possible future directions for smFRET in applications such as biosensing, high-throughput screening, and molecular diagnostics.
Bio-macromolecules carry out complicated functions through structural changes. To understand their mechanism of action, the structure of each step has to be characterized. While classical structural biology techniques allow the characterization of a few "structural snapshots" along the enzymatic cycle (usually of stable conformations), they do not cover all (and often fast interconverting) structures in the ensemble, where each may play an important functional role. Recently, several groups have demonstrated that structures of different conformations in solution could be solved by measuring multiple distances between different pairs of residues using single-molecule Förster resonance energy transfer (smFRET) and using them as constrains for hybrid/integrative structural modeling. However, this approach is limited in cases where the conformational dynamics is faster than the technique's temporal resolution. In this study, we combine existing tools that elucidate sub-millisecond conformational dynamics together with hybrid/integrative structural modeling to study the conformational states of the transcription bubble in the bacterial RNA polymerase-promoter open complex (RPo). We measured microsecond alternating laser excitation-smFRET of differently labeled lacCONS promoter dsDNA constructs. We used a combination of burst variance analysis, photon-by-photon hidden Markov modeling, and the FRET-restrained positioning and screening approach to identify two conformational states for RPo. The experimentally derived distances of one conformational state match the known crystal structure of bacterial RPo. The experimentally derived distances of the other conformational state have characteristics of a scrunched RPo. These findings support the hypothesis that sub-millisecond dynamics in the transcription bubble are responsible for transcription start site selection.
We developed membrane voltage nanosensors that are based on inorganic semiconductor nanoparticles. We provide here a feasibility study for their utilization. We use a rationally designed peptide to functionalize the nanosensors, imparting them with the ability to self-insert into a lipid membrane with a desired orientation. Once inserted, these nanosensors could sense membrane potential via the quantum confined Stark effect, with a single-particle sensitivity. With further improvements, these nanosensors could potentially be used for simultaneous recording of action potentials from multiple neurons in a large field of view over a long duration and for recording electrical signals on the nanoscale, such as across one synapse.
Monitoring membrane potential in neurons requires sensors with minimal invasiveness, high spatial and temporal (sub-ms) resolution, and large sensitivity for enabling detection of sub-threshold activities. While organic dyes and fluorescent proteins have been developed to possess voltage-sensing properties, photobleaching, cytotoxicity, low sensitivity, and low spatial resolution have obstructed further studies. Semiconductor nanoparticles (NPs), as prospective voltage sensors, have shown excellent sensitivity based on Quantum confined Stark effect (QCSE) at room temperature and at single particle level. Both theory and experiment have shown their voltage sensitivity can be increased significantly via material, bandgap, and structural engineering. Based on theoretical calculations, we synthesized one of the optimal candidates for voltage sensors: 12 nm type-II ZnSe/CdS nanorods (NRs), with an asymmetrically located seed. The voltage sensitivity and spectral shift were characterized in vitro using spectrally-resolved microscopy using electrodes grown by thin film deposition, which "sandwich" the NRs. We characterized multiple batches of such NRs and iteratively modified the synthesis to achieve higher voltage sensitivity (Delta F/F>10%), larger spectral shift (>5 nm), better homogeneity, and better colloidal stability. Using a high throughput screening method, we were able to compare the voltage sensitivity of our NRs with commercial spherical quantum dots (QDs) with single particle statistics. Our method of high throughput screening with spectrally-resolved microscope also provides a versatile tool for studying single particles spectroscopy under field modulation.
We describe an 8-spot confocal setup for high-throughput smFRET assays and illustrate its performance with two characteristic experiments. First, measurements on a series of freely diffusing doubly-labeled dsDNA samples allow us to demonstrate that data acquired in multiple spots in parallel can be properly corrected and result in measured sample characteristics consistent with those obtained with a standard single-spot setup. We then take advantage of the higher throughput provided by parallel acquisition to address an outstanding question about the kinetics of the initial steps of bacterial RNA transcription. Our real-time kinetic analysis of promoter escape by bacterial RNA polymerase confirms results obtained by a more indirect route, shedding additional light on the initial steps of transcription. Finally, we discuss the advantages of our multispot setup, while pointing potential limitations of the current single laser excitation design, as well as analysis challenges and their solutions.
Single-molecule fluorescence spectroscopy (SMFS), based on the detection of individual molecules freely diffusing through the excitation spot of a confocal microscope, has allowed unprecedented insights into biological processes at the molecular level, but suffers from limited throughput. We have recently introduced a multispot version of SMFS, which allows achieving high-throughput SMFS by virtue of parallelization, and relies on custom silicon single-photon avalanche diode (SPAD) detector arrays. Here, we examine the premise of this parallelization approach, which is that data acquired from different spots is uncorrelated. In particular, we measure the optical crosstalk characteristics of the two 48-pixel SPAD arrays used in our recent SMFS studies, and demonstrate that it is negligible (crosstalk probability ≤1.110−3) and undetectable in cross-correlation analysis of actual single-molecule fluorescence data.
These are usALEX smFRET burst data for measurements of lacCONS promoter DNA doubly labeled at different positions to probe bubble opening. Each construct is measured three times:1. Free DNA2. RNAP-promoter open bubble (RPo) complex3. RPo complex after addition of all NTPs - promoter escape and run-off
In many cases, initiation is rate limiting to transcription. This due in part to the multiple cycles of abortive transcription that delay promoter escape and the transition from initiation to elongation. Pausing of transcription in initiation can further delay promoter escape. The previously hypothesized pausing in initiation was confirmed by two recent studies from Duchi et al.(1) and from Lerner, Chung et al.(2) In both studies, pausing is attributed to a lack of forward translocation of the nascent transcript during initiation. However, the two works report on different pausing mechanisms. Duchi et al. report on pausing that occurs during initiation predominantly on-pathway of transcript synthesis. Lerner, Chung et al. report on pausing during initiation as a result of RNAP backtracking, which is off-pathway to transcript synthesis. Here, we discuss these studies, together with additional experimental results from single-molecule FRET focusing on a specific distance within the transcription bubble. We show that the results of these studies are complementary to each other and are consistent with a model involving two types of pauses in initiation: a short-lived pause that occurs in the translocation of a 6-mer nascent transcript and a long-lived pause that occurs as a result of 1-2 nucleotide backtracking of a 7-mer transcript.
This data set is a collection of usALEX smFRET burst data measured for the lacCONS promoter DNA labeled at the transcription bubble region (in initiation). Each measurement follows the results in different steady-state initiation states.
Measurements used in:48-spot single-molecule FRET setup with periodic acceptor excitationIngargiola et al., bioRxiv (2017), doi: *to-be-issued*Copyright (C) 2017 The Regents of the University of California
Single-molecule spectroscopy on freely-diffusing molecules allows detecting conformational changes of biomolecules without perturbation from surface immobilization. Resolving fluorescence lifetimes increases the sensitivity in detecting conformational changes and overcomes artifacts common in intensity-based measurements. Common to all freely-diffusing techniques, however, are the long acquisition times. We report a time-resolved multispot system employing a 16-channel SPAD array and TCSPC electronics, which overcomes the throughput issue. Excitation is obtained by shaping a 532 nm pulsed laser into a line, matching the linear SPAD array geometry. We show that the line-excitation is a robust and cost-effective approach to implement multispot systems based on linear detector arrays.