EDITORIAL article Front. Public Health, 05 January 2023Sec. Radiation and Health Volume 10 - 2022 | https://doi.org/10.3389/fpubh.2022.1117269
Translocation analysis using fluorescence in situ hybridization (FISH) is the method of choice for dose assessment in case of chronic or past exposures to ionizing radiation. Although it is a widespread technique, unlike dicentrics, the number of FISH-based inter-laboratory comparisons is small. For this reason, although the current Running the European Network of Biological and Physical retrospective Dosimetry (RENEB) inter-laboratory comparison 2021 was designed as a fast response to a real emergency scenario, it was considered a good opportunity to perform an inter-laboratory comparison using the FISH technique to gain further experience. The Bundeswehr Institute of Radiobiology provided peripheral blood samples from one healthy human volunteer. Three test samples were irradiated with blinded doses of 0, 1.2, and 3.5 Gy, respectively. Samples were then sent to the seven participating laboratories. The FISH technique was applied according to the standard procedure of each laboratory. Both, the frequency of translocations and the estimated dose for each sample were sent to the coordinator using a special scoring sheet for FISH. All participants sent their results in due time. However, although it was initially requested to send the results based on the full analysis, evaluating 500 equivalent cells, most laboratories only sent the results based on triage, with a smaller number of analyzed cells. In the triage analysis, there was great heterogeneity in the number of equivalent cells scored. On the contrary, for the full analysis, this number was more homogeneous. For all three samples, one laboratory showed outlier yields compared to the other laboratories. Excluding these results, in the triage analysis, the frequency of translocations in sample no. 1 ranged from 0 to 0.013 translocations per cell, and for samples no. 2 and no. 3 the genomic mean frequency were 0.27 ± 0.03 and 1.47 ± 0.14, with a coefficient of variation of 0.29 and 0.23 respectively. Considering only results obtained in the triage analysis for sample no. 1, all laboratories, except one, classified this sample as the non-irradiated one. For sample no. 2, excluding the outlier value, the mean reported dose was 1.74 ± 0.16 Gy indicating a mean deviation of about 0.5 Gy to the delivered dose of 1.2 Gy. For sample no. 3 the mean dose estimated was 4.21 ± 0.21 Gy indicating a mean deviation of about 0.7 Gy to the delivered dose of 3.5 Gy. In the frame of RENEB, this is the second FISH-based inter-laboratory comparison. The whole exercise was planned as a response to an emergency, therefore, a triage analysis was requested for all the biomarkers except for FISH. Although a full analysis was initially requested for FISH, most of the laboratories reported only a triage-based result. The main reason is that it was not clearly stated what was required before starting the exercise. Results show that most of the laboratories successfully discriminated unexposed and irradiated samples from each other without any overlap. A good agreement in the observed frequencies of translocations was observed but there was a tendency to overestimate the delivered doses. Efforts to improve the harmonization of this technique and subsequent exercises to elucidate the reason for this trend should be promoted.
The goal of the RENEB inter-laboratory comparison 2021 exercise was to simulate a large-scale radiation accident involving a network of biodosimetry labs. Labs were required to perform their analyses using different biodosimetric assays in triage mode scoring and to rapidly report estimated radiation doses to the organizing institution. This article reports the results obtained with the cytokinesis-block micronucleus assay. Three test samples were exposed to blinded doses of 0, 1.2 and 3.5 Gy X-ray doses (240 kVp, 13 mA, ∼75 keV, 1 Gy/min). These doses belong to 3 triage categories of clinical relevance: a low dose category, for no exposure or exposures inferior to 1 Gy, requiring no direct treatment of subjects; a medium dose category, with doses ranging from 1 to 2 Gy, and a high dose category, after exposure to doses higher than 2 Gy, with the two latter requiring increasing medical attention. After irradiation the test samples (no. 1, no. 2 and no. 3) were sent by the organizing laboratory to 14 centers participating in the micronucleus assay exercise. Laboratories were asked to setup micronucleus cultures and to perform the micronucleus assay in triage mode, scoring 500 binucleated cells manually, or 1,000 binucleated cells in automated/semi-automated mode. One laboratory received no blood samples, but scored pictures from another lab. Based on their calibration curves, laboratories had to provide estimates of the administered doses. The accuracy of the reported dose estimates was further analyzed by the micronucleus assay lead. The micronucleus assay allowed classification of samples in the corresponding clinical triage categories (low, medium, high dose category) in 88% of cases (manual scoring, 88%; semi-automated scoring, 100%; automated scoring, 73%). Agreement between scoring laboratories, assessed by calculating the Fleiss' kappa, was excellent (100%) for semi-automated scoring, good (83%) for manual scoring and poor (53%) for fully automated scoring. Correct classification into triage scoring dose intervals (reference dose ±0.5 Gy for doses ≤2.5 Gy, or reference dose ±1 Gy for doses >2.5 Gy), recommended for triage biodosimetry, was obtained in 79% of cases (manual scoring, 73%; semi-automated scoring, 100%; automated scoring, 67%). The percentage of dose estimates whose 95% confidence intervals included the reference dose was 58% (manual scoring, 48%; semiautomated scoring, 72%; automated scoring, 60%). For the irradiated samples no. 2 and no. 3, a systematic shift towards higher dose estimations was observed. This was also noticed with the other cytogenetic assays in this intercomparison exercise. Accuracy of the rapid triage modality could be maintained when the number of manually scored cells was scaled down to 200 binucleated cells. In conclusion, the micronucleus assay, preferably performed in a semi-automated or manual scoring mode, is a reliable technique to perform rapid biodosimetry analysis in large-scale radiation emergencies.
After large-scale radiation accidents where many individuals are suspected to be exposed to ionizing radiation, biological and physical retrospective dosimetry assays are important tools to aid clinical decision making by categorizing individuals into unexposed/minimally, moderately or highly exposed groups. Quality-controlled inter-laboratory comparisons of simulated accident scenarios are regularly performed in the frame of the European legal association RENEB (Running the European Network of Biological and Physical retrospective Dosimetry) to optimize international networking and emergency readiness in case of large-scale radiation events. In total 33 laboratories from 22 countries around the world participated in the current RENEB inter-laboratory comparison 2021 for the dicentric chromosome assay. Blood was irradiated in vitro with X rays (240 kVp, 13 mA, ∼75 keV, 1 Gy/min) to simulate an acute, homogeneous whole-body exposure. Three blood samples (no. 1: 0 Gy, no. 2: 1.2 Gy, no. 3: 3.5 Gy) were sent to each participant and the task was to culture samples, to prepare slides and to assess radiation doses based on the observed dicentric yields from 50 manually or 150 semi-automatically scored metaphases (triage mode scoring). Approximately two-thirds of the participants applied calibration curves from irradiations with γ rays and about 1/3 from irradiations with X rays with varying energies. The categorization of the samples in clinically relevant groups corresponding to individuals that were unexposed/minimally (0–1 Gy), moderately (1–2 Gy) or highly exposed (>2 Gy) was successfully performed by all participants for sample no. 1 and no. 3 and by ≥74% for sample no. 2. However, while most participants estimated a dose of exactly 0 Gy for the sham-irradiated sample, the precise dose estimates of the samples irradiated with doses >0 Gy were systematically higher than the corresponding reference doses and showed a median deviation of 0.5 Gy (sample no. 2) and 0.95 Gy (sample no. 3) for manual scoring. By converting doses estimated based on γ-ray calibration curves to X-ray doses of a comparable mean photon energy as used in this exercise, the median deviation decreased to 0.27 Gy (sample no. 2) and 0.6 Gy (sample no. 3). The main aim of biological dosimetry in the case of a large-scale event is the categorization of individuals into clinically relevant groups, to aid clinical decision making. This task was successfully performed by all participants for the 0 Gy and 3.5 Gy samples and by 74% (manual scoring) and 80% (semiautomatic scoring) for the 1.2 Gy sample. Due to the accuracy of the dicentric chromosome assay and the high number of participating laboratories, a systematic shift of the dose estimates could be revealed. Differences in radiation quality (X ray vs. γ ray) between the test samples and the applied dose effect curves can partly explain the systematic shift. There might be several additional reasons for the observed bias (e.g., donor effects, transport, experimental conditions or the irradiation setup) and the analysis of these reasons provides great opportunities for future research. The participation of laboratories from countries around the world gave the opportunity to compare the results on an international level.
Kazakhstan is known as a country with a complex radioecological situation resulting from different sources such as a natural radiation background, extensive activities of the industrial system of the former Soviet Union and a well-known testing of nuclear power weapons occurred in the Semipalatinsk Test Site (STS) area. The present study focuses on the assessment of the background of dicentric chromosomes in Kazakhstan’s population, which is the starting point in the dose assessment of irradiated people, since the baseline level of spontaneous dicentrics can vary significantly in different populations. In this context, aiming to determine the background frequency of chromosome aberrations in the population of Kazakhstan, considering the heterogeneity of natural radiation background levels of its large territory, a selection of 40 control subjects living in four cities of North, South, West and East Kazakhstan was performed. The cytogenetic study on the selected groups showed fairly low background frequency values of chromosome aberrations (0.84 ± 0.83 per 1000 cells), comparable with other data in the literature on general populations, reporting background frequency values between 0.54 and 2.99 per 1000 cells. The obtained results should be taken into account when constructing the dose–effect calibration curve used in cytogenetic biodosimetry, as a “zero” dose point, which will reduce the uncertainty in quantifying the individual absorbed dose in emergency radiological situations.
Background 223 Ra is currently used for treatment of metastatic castration resistant prostate cancer patients (mCRPC) bone metastases with fixed standard activity. Individualized treatments, based on adsorbed dose (AD) in target and non-target tissue, are absolutely needed to optimize efficacy while reducing toxicity of α-emitter targeted therapy. This is a pilot first in human clinical trial aimed to correlate dosimetry, clinical response and biological side effects to personalize 223 Ra treatment. Methods Out of 20 mCRPC patients who underwent standard 223 Ra treatment and dosimetry, in a subset of 5 patients the AD to target and non-target tissues was correlated with clinical effects and radiation-induced chromosome damages. Before each 223 Ra administrations, haematological parameters, PSA and ALP values were evaluated. Additional blood samples were obtained baseline (T0), at 7 days (T7), 30 days (T30) and 180 days (T180) to evaluate chromosome damage. After administration WB planar 223 Ra images were obtained at 2–4 and 18–24 h. Treatment response and toxicity were monitored with clinical evaluation, bone scan, 18F-choline-PET/CT, PSA value and ALP while haematological parameters were evaluated weekly after 223 Ra injection and 2 months after last cycle. Results 1. a correlation between AD to target and clinical response was evidenced with threshold of 20 Gy as a cut-off to obtain tumor control; 2. the AD to red marrow was lower than 2 Gy in all the patients with no apparently correlation between dosimetry and clinical toxicity. 3. a high dose dependent increase of the number of dicentrics and micronuclei during the course of 223 Ra therapy was observed and a linear correlation has been found between blood AD (BAD) and number of dicentrics. Conclusions This study provides some interesting preliminary evidence to be further investigated: dosimetry may be useful to identify a more appropriate 223 Ra administered activity predicting AD to target tissue; a dose dependent complex chromosome damage occurs during 223 Ra administration and this injury is more evident in heavily pre-treated patients; dosimetry could be used for radioprotection purpose. Trial registration The pilot study has been approved from the Ethics Committee of Regina Elena National Cancer Institute (N:RS1083/18–2111).
PURPOSE:Biological and/or physical assays for retrospective dosimetry are valuable tools to recover the exposure situation and to aid medical decision making. To further validate and improve such biological and physical assays, in 2019, EURADOS Working Group 10 and RENEB performed a field exercise in Lund, Sweden, to simulate various real-life exposure scenarios. MATERIALS AND METHODS:For the dicentric chromosome assay (DCA), blood tubes were located at anthropomorphic phantoms positioned in different geometries and were irradiated with a 1.36 TBq 192Ir-source. For each exposure condition, dose estimates were provided by at least one laboratory and for four conditions by 17 participating RENEB laboratories. Three radio-photoluminescence glass dosimeters were placed at each tube to assess reference doses. RESULTS:The DCA results were homogeneous between participants and matched well with the reference doses (≥95% of estimates within ±0.5 Gy of the reference). For samples close to the source systematic underestimation could be corrected by accounting for exposure time. Heterogeneity within and between tubes was detected for reference doses as well as for DCA doses estimates. CONCLUSIONS:The participants were able to successfully estimate the doses and to provide important information on the exposure scenarios under conditions closely resembling a real-life situation.
Purpose In case of a mass-casualty radiological event, there would be a need for networking to overcome surge limitations and to quickly obtain homogeneous results (reported aberration frequencies or estimated doses) among biodosimetry laboratories. These results must be consistent within such network. Inter-laboratory comparisons (ILCs) are widely accepted to achieve this homogeneity. At the European level, a great effort has been made to harmonize biological dosimetry laboratories, notably during the MULTIBIODOSE and RENEB projects. In order to continue the harmonization efforts, the RENEB consortium launched this intercomparison which is larger than the RENEB network, as it involves 38 laboratories from 21 countries. In this ILC all steps of the process were monitored, from blood shipment to dose estimation. This exercise also aimed to evaluate the statistical tools used to compare laboratory performance. Materials and methods Blood samples were irradiated at three different doses, 1.8, 0.4 and 0 Gy (samples A, C and B) with 4-MV X-rays at 0.5 Gy min(-1), and sent to the participant laboratories. Each laboratory was requested to blindly analyze 500 cells per sample and to report the observed frequency of dicentric chromosomes per metaphase and the corresponding estimated dose. Results This ILC demonstrates that blood samples can be successfully distributed among laboratories worldwide to perform biological dosimetry in case of a mass casualty event. Having achieved a substantial harmonization in multiple areas among the RENEB laboratories issues were identified with the available statistical tools, which are not capable to advantageously exploit the richness of results of a large ILCs. Even though Z- and U-tests are accepted methods for biodosimetry ILCs, setting the number of analyzed metaphases to 500 and establishing a tests' common threshold for all studied doses is inappropriate for evaluating laboratory performance. Another problem highlighted by this ILC is the issue of the dose-effect curve diversity. It clearly appears that, despite the initial advantage of including the scoring specificities of each laboratory, the lack of defined criteria for assessing the robustness of each laboratory's curve is a disadvantage for the 'one curve per laboratory' model. Conclusions Based on our study, it seems relevant to develop tools better adapted to the collection and processing of results produced by the participant laboratories. We are confident that, after an initial harmonization phase reached by the RENEB laboratories, a new step toward a better optimization of the laboratory networks in biological dosimetry and associated ILC is on the way.
This work presents an overview of the applications of retrospective dosimetry techniques in case of incorporation of radionuclides. The fact that internal exposures are characterized by a spatially inhomogeneous irradiation of the body, which is potentially prolonged over large periods and variable over time, is particularly problematic for biological and electron paramagnetic resonance (EPR) dosimetry methods when compared with external exposures. The paper gives initially specific information about internal dosimetry methods, the most common cytogenetic techniques used in biological dosimetry and EPR dosimetry applied to tooth enamel. Based on real-case scenarios, dose estimates obtained from bioassay data as well as with biological and/or EPR dosimetry are compared and critically discussed. In most of the scenarios presented, concomitant external exposures were responsible for the greater portion of the received dose. As no assay is available which can discriminate between radiation of different types and different LETs on the basis of the type of damage induced, it is not possible to infer from these studies specific conclusions valid for incorporated radionuclides alone. The biological dosimetry assays and EPR techniques proved to be most applicable in cases when the radionuclides are almost homogeneously distributed in the body. No compelling evidence was obtained in other cases of extremely inhomogeneous distribution. Retrospective dosimetry needs to be optimized and further developed in order to be able to deal with real exposure cases, where a mixture of both external and internal exposures will be encountered most of the times.
In case of Radiological and Nuclear (R/N) emergencies, the early knowledge on the individual radiation absorbed dose is of paramount importance for sorting out unaffected subjects from those requiring medical intervention. Retrospective dosimetry by using biological and physical methods aims to prioritize the selection of over-exposed individuals for a rapid triage-dose assessment. In this context, the BioPhyMeTRE project focuses on the validation of innovative biological and physical methods allowing a rapid screening/triage of potential victims, by using inexpensive and user-friendly analytical procedures and devices. The biological method combines the two most standardized biodosimetry methods into a single one and the physical technique concerns the use of a low-cost, portable mini photo-luminescence reader for the individual dose assessment by using personal objects that civilians wear or carry every day. Next to the experimental work, the project includes training for the transfer of knowledge and skills among the partners, inter-laboratory exercises for the validation of the analytical procedures and disseminations of the results. The preliminary results of these activities are here reported.
Biological dosimetry methods are well established and validated for providing dose estimates following external radiation exposures. In contrast, interpreting biological dosimetry data in cases of internal exposures is still challenging. In this context, a joint collaboration between two Working Groups (WG) of European Radiation Dosimetry Group (EURADOS), WG10 on 'Retrospective Dosimetry' and WG7 on 'Internal Dosimetry', was initiated with the aim to address the main issues related to the advantages and limitations of biological and electron paramagnetic resonance (EPR) dosimetry in cases of internal and mixed internal/external exposures. The organization of the review work, the main findings of the analysis performed and the driving lines for possible future research work are briefly described in the present document.
In case of mass radiological emergencies, new strategies involving biological and clinical endpoints are requested for an efficient triage classification of casualties. For this purpose, we developed a novel protocol combining the two most established cytogenetic methods used in biological dosimetry (dicentric and micronucleus assays) into a single one, in order to have a time-saving, inexpensive and potentially automatable instrument to be used for triage purposes in case of large-scale radiological events. This method could be considered as a 'three in one' assay allowing the simultaneous scoring of chromosome aberrations and micronuclei on a single slide, and also enabling to discriminate between metaphases in first and second cell division without the Fluorescence plus Giemsa staining. This method needs further validation through inter-comparisons involving biological dosimetry laboratories, to verify its reproducibility. Moreover, the possibility to apply the already existing software for automation for dicentric and micronucleus assays could be also verified.
Biological dosimetry is an essential tool for estimating radiation doses received from individuals when the physical dosimetry is not available or inadequate. Early knowledge about the absorbed dose levels in radiation accidents is of paramount importance for selecting the unaffected subjects from those individuals requiring medical evaluation and intervention. A lesson learned from many radiological incidents is the importance to identify the "worried well." Several assays are useful for biological dosimetry approaches, since no one single assay is sufficiently robust for all potential radiation scenarios including early-phase acute exposures, partial-body exposures, and biosampling years after exposure or in case of suspected mixed exposures (radiological and chemicals). The most commonly used biodosimetry methods are based on the evaluation of the radiation-specific dicentric chromosomes (Dic) and micronuclei (MN) in exposed individuals' peripheral blood lymphocytes (PBL). The present chapter does not claim to make an exhaustive and complete picture on the complex world of biodosimetry, to which a large number of specific guidelines for performing laboratory services by the International Organization for Standardization (ISO) are dedicated, but it aims to support the reader in understanding the application of two cytogenetic methods in the individual ionizing radiation dose assessment, suggesting some appropriate scientific sources to consult for each case.
Purpose The purpose of this study is to correlate the physical dose to non-target tissues (blood) to the radiation-induced chromosome damage in terms of the dicentrics and micronuclei (MN) in peripheral blood lymphocytes (PBL) after radium-223 (223RaCl2) therapy in patients with bone metastasis derived from prostate cancer [1] . Methods Four patients undergoing 223RaCl2 therapy for skeletal diseases have been enrolled in this prospective clinical study. The effective dose to blood per injected activity was calculated considering the alpha, beta and gamma emission of Ra-223 and considering a standard man weight of 70 kg. PBL cultures for dicentric assay and MN were performed before treatment (T0), 6 days (T1) and 30 days (T2) after the first cycle of treatment and after the end of the therapy (T3). Haematological toxicity parameters (blood cell count) have been monitored during therapy and analysed along with doses to blood. Results The administration of 223RaCl2 produces a high dose dependent increase of radiation-induced chromosome damage in terms of dicentrics and MN induction observed in the circulating lymphocytes. Surprisingly, the increase of chromosome damage observed between T1 and T2 is not due to an 223RaCl2 addition dose, suggesting that circulating lymphocytes were exposed to an extra dose by the emissions from the target areas. In addition, clinical monitoring during the treatment showed a progressive increasing fatigue, leucopenia and anemia with a partial recovery after some months after the end of therapy. Conclusions The cytogenetic data suggest a persistence of the radiation emission from the target tissue to non-target ones and seem to be correlated to the observed haematological toxicity, highlighting possible adverse effects related to this therapy. These data need further investigation in order to evaluate the potential side effects to normal, non-target tissue in patients treated with alpha emitters.
Substantial evidences suggest that reactive oxygen species participate in the normal aging process and in cancer and neurodegenerative age-related diseases. Parkinson's disease (PD), one of the most common oxidative stress associated pathology in aging people, is treated with a standard pharmacological protocol consisting in a combined therapy L-dopa plus an inhibitor of dopa-decarboxylase, such as carbidopa. The therapy is well validated for the ability to restoring dopaminergic neurotransmission in PD patients, while L-dopa and carbidopa ability in modulating oxidative stress is currently under discussion. Our aim was to evaluate the impact of L-dopa and carbidopa on several biomarkers of exogenously-induced oxidative stress to validate the overall antioxidant effectiveness of the therapy. For this purpose we used peripheral blood lymphocytes from healthy donors treated in vitro with L-dopa and carbidopa and then challenged by different concentrations of H2O2. Glutathione (GSH, GSSG, GSH/GSSG), malondialdehyde (TBARs), protein carbonyls as well as DNA damage (8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) and micronuclei (MN)), modulation was evaluated. Our results show that L-dopa, but not carbidopa, decreases the markers of lipid and protein oxidation and increases the total content of glutathione. Both L-dopa and carbidopa (alone or in combination) are able to counteract the formation of 8-oxodG and to reduce H2O2-induced micronuclei.
Abstract Reactive oxygen species (ROS) are important mediators of the cytotoxicity induced by the direct reaction of ionising radiation (IR) with all critical cellular components, such as proteins, lipids, and nucleic acids. The derived oxidative damage may propagate in exposed tissues in a dose- and spatiotemporal dependent manner to other cell compartments, affecting intracellular signalling, and cell fate. To understand how cell damage is induced, we studied the oxidative events occurring immediately after cell irradiation by analysing the fate of IR-derived ROS, the intracellular oxidative damage, and the modification of redox environment accumulating in Chinese hamster ovary (CHO) within 1 h after cell irradiation (dose range 0–10 Gy). By using the immuno-spin trapping technique (IST), spectrophotometric methods, and electron paramagnetic resonance (EPR) spectroscopy, we showed that IR-derived ROS (i) induced an IST-detectable, antioxidant-inhibitable one-electron oxidation of specific intracellular proteins; (ii) altered the glutathione (GSH) content (which was found to increase below 2 Gy, and decrease at higher doses, leading to a redox imbalance); (iii) decreased glutathione peroxidase and glutaredoxin activity; (iv) modified neither glutathione reductase nor thioredoxin reductase activity; (v) were detected by spin trapping technique, but adduct intensity decreased due to cell competition for ROS; and (vi) induced no EPR-detectable radicals assignable to oxidised cellular components. In conclusion, our results showed that IR generated an early high oxidising potential (protein radical intermediates, redox imbalance, modified redox enzyme activity) in irradiated cells potentially able to propagate the damage and induce oxidative modification of secondary targets.
There is a continued need for further clarification of various aspects of radiation-induced chromosomal aberration, including its correlation with radiation track structure. As part of the EMRP joint research project, Biologically Weighted Quantities in Radiotherapy (BioQuaRT), we performed experimental and theoretical analyses on chromosomal aberrations in Chinese hamster ovary cells (CHO-K1) exposed to α particles with final energies of 5.5 and 17.8 MeV (absorbed doses: ∼2.3 Gy and ∼1.9 Gy, respectively), which were generated by the microbeam at the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig, Germany. In line with the differences in linear energy transfer (approximately 85 keV/μm for 5.5 MeV and 36 keV/μm for 17.8 MeV α particles), the 5.5 MeV α particles were more effective than the 17.8 MeV α particles, both in terms of the percentage of aberrant cells (57% vs. 33%) and aberration frequency. The yield of total aberrations increased by a factor of ∼2, although the increase in dicentrics plus centric rings was less pronounced than in acentric fragments. The experimental data were compared with Monte Carlo simulations based on the BIophysical ANalysis of Cell death and chromosomal Aberrations model (BIANCA). This comparison allowed interpretation of the results in terms of critical DNA damage [cluster lesions (CLs)]. More specifically, the higher aberration yields observed for the 5.5 MeV α particles were explained by taking into account that, although the nucleus was traversed by fewer particles (nominally, 11 vs. 25), each particle was much more effective (by a factor of ∼3) at inducing CLs. This led to an increased yield of CLs per cell (by a factor of ∼1.4), consistent with the increased yield of total aberrations observed in the experiments.
Purpose The purpose of this study is to correlate the physical dose to non-target tissues to the radiation-induced chromosome damage in terms of the dicentrics and micronuclei (MN) in peripheral blood lymphocytes (PBL) after radium-223 chloride (223RaCl2) therapy in patients with bone metastasis derived from prostate cancer [1] . Methods Four patients undergoing 223RaCl2 therapy for skeletal diseases have been enrolled in this prospective clinical study. The effective dose to non-target tissues per injected activity was calculated considering the alpha, beta and gamma emission of Ra-223 and considering a standard man weight of 70 kg. PBL cultures for dicentric assay and micronuclei induction were performed before treatment (T0), 6 days (T1) and 30 days (T2) after the first cycle of treatment. Haematological toxicity parameters (blood cell count) have been monitored during therapy and analysed along with doses to blood and non-target tissues. Results The administration of 223RaCl2 produces a high dose dependent increase of radiation-induced chromosome damage in terms of dicentrics and micronuclei observed in the circulating lymphocytes (non target-tissue). Surprisingly, this increase of chromosome damage observed is not due to an 223RaCl2 addition dose, suggesting that circulating lymphocytes were exposed to an extra dose by the emissions from the target organs. In addition, clinical monitoring during the treatment showed a progressive increasing fatigue, leucopenia and anemia with a partial recovery after some months after the end of therapy. Conclusions The cytogenetic data seem to suggest a persistence of the radiation emission from the target tissue to non-target ones and seem to be correlated to the observed haematological toxicity, highlighting possible adverse effects related to this therapy. These data need further investigation in order to evaluate the potential side effects to normal, non-target tissue in patients treated with alpha emitters.
Purpose: To establish a training data set of digital images and to investigate the scoring criteria and dose assessment of the dicentric assay within the European network of biodosimetry (RENEB), a web based scoring inter-comparison was undertaken by 17 RENEB partners.Materials and methods: Two sets of 50 high resolution images were uploaded onto the RENEB web site. One set included metaphases after a moderate exposure (1.3 Gy) and the other set consisted of metaphases after a high dose exposure (3.5 Gy). The laboratories used their own calibration curves for estimating doses based on observed aberration frequencies.Results: The dose estimations and 95% confidence limits were compared to the actual doses and the corresponding z-values were satisfactory for the majority; only the dose estimations from two laboratories were too low or too high. The coefficients of variation were 17.6% for the moderate and 11.2% for the high dose. Metaphases with controversial results could be identified for training purposes.Conclusions: Overall, the web based scoring of the two galleries by the 17 laboratories produced very good results. Application of web based scoring for the dicentric assay may therefore be a relevant strategy for an operational biodosimetry assistance network.