Accurate and rapid detection of pathogens in foods of animal origin has been a critical part of the One Health Action Plan of the European Union (EU). Biosensors have the potential in bringing required technologies to accomplish this on the field, wherein loop-mediated isothermal amplification (LAMP) and lab-on-a-chip have proven to be ideal. We have developed a LAMP-based point-of-care (POC) device, the VETPOD, as a solution to the contemporary challenges in the rapid detection of Salmonella spp. The core technology in the VETPOD is a ready-to-use cartridge that included an injection-molded polymer chip with pyramid-shaped optical structures embedded within the chip. These pyramid-shaped optical structures direct the incident light, due to total internal reflection (TIR), through the reaction chambers to the phototransistor. The VETPOD was validated against the ISO 6579-1 reference method. A total of 310 samples were tested that included 180 Salmonella spiked samples in 6 different meat categories and 130 strains to determine the specificity. The overall results were satisfactory, wherein the VETPOD had an acceptable sensitivity (96.51%) compared to the reference (98.81%) and near perfect agreement with ISO 6579-1 with an overall Cohen's kappa of 0.94. The relative level of detection (RLOD) for the VETPOD was 1.38 CFU/25 g that was found to be 1.17 times higher than the reference. The VETPOD showed 98% precision for inclusivity and 100% precision for the exclusivity samples. The VETPOD proved as a useful alternative to detect Salmonella spp. that can be adaptable to a broader spectrum of pathogens in future.
Sensitive and rapid detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been a vital goal in the ongoing COVID-19 pandemic. We present in this comprehensive work, for the first time, detailed fabrication and clinical validation of a point of care (PoC) device for rapid, onsite detection of SARS-CoV-2 using a real-time reverse-transcription loop-mediated isothermal amplification (RT-LAMP) reaction on a polymer cartridge. The PoC system, namely PATHPOD, consisting of a standalone device (weight less than 1.2 kg) and a cartridge, can perform the detection of 10 different samples and two controls in less than 50 min, which is much more rapid than the golden standard real-time reverse-transcription Polymerase Chain Reaction (RT-PCR), typically taking 16-48 h. The novel total internal reflection (TIR) scheme and the reactions inside the cartridge in the PoC device allow monitoring of the diagnostic results in real-time and onsite. The analytical sensitivity and specificity of the PoC test are comparable with the current RT-PCR, with a limit of detection (LOD) down to 30-50 viral genome copies. The robustness of the PATHPOD PoC system has been confirmed by analyzing 398 clinical samples initially examined in two hospitals in Denmark. The clinical sensitivity and specificity of these tests are discussed.
Sensitive detection of pathogens in livestock farms is an integral part of the One Health Action Plan of the European Union (EU). Ensuring this requires on-site testing devices that are compatible with complex matrices such as primary production samples. Among all, faeces are considered the most challenging matrix type that makes it difficult to identify pathogens because of complexity in sample preparation for molecular testing. We have developed a loop-mediated isothermal amplification (LAMP) based veterinary point-of-care (POC) device (VETPOD) and adapted it to detect Salmonella enterica in primary production samples. Three different sampling methods (semi-wet chicken faeces, boot socks collection and dust samples from poultry shed) were iteratively tested to assess their nature of complexity and possibility for adapting them as suitable sampling methods for on-site testing. During the study, the sample preparation method that included a two-step centrifugation combined with washing of the enriched Salmonella cells was found crucial in eliminating amplification inhibitors originating from the faecal matrices. A total of 90 samples were tested that included 60 samples for sensitivity study and 30 samples for relative level of detection (RLOD, a level of detection in comparison to ISO 6579:1 reference method). Overall, the VETPOD had a sensitivity of 90%, 84.62% and 81.82% for boot sock, faecal and dust samples, respectively. The RLOD was 2.23 CFU/25 g which was found to be 1.33 times higher than the ISO 6579:1. Performing with an excellent agreement with ISO 6579:1, the VETPOD proved as a promising alternative to detect Salmonella spp. in primary production and animal husbandry samples.
In the ongoing COVID-19 pandemic, sensitive and rapid on-site detection of the SARS-CoV-2 coronavirus has been one of crucial objectives. A point-of-care (PoC) device called PATHPOD for quick, on-site detection of SARS-CoV-2 employing a real-time reverse-transcription loop-mediated isothermal amplification (RT-rLAMP) reaction on a polymer cartridge. The PATHPOD consists of a standalone device (weighing under 1.2 kg) and a cartridge, and can identify 10 distinct samples and 2 controls in less than 50 minutes. The PATHPOD PoC system is fabricated and clinically validated for the first time in this work
Adaptations of new generation molecular techniques for multiplexed detection of pathogens are gaining interest in the field of point-of-care (POC) industry and onsite testing. Loop-mediated isothermal amplification (LAMP), an advanced molecular amplification technique, has proven promising due to its unique features that suits ideal for POC applications. However, application of LAMP for multiplexed detection of pathogens remains challenging because of the difficulty in the identification of specific LAMP amplicons that does not have a well-definite molecular size. In this study, we developed a solid-phase loop-mediated isothermal amplification (SP-LAMP) technique to address the challenge. Integration of LAMP with the supercritical angle fluorescence (SAF) micro-optic structures as a solid support (SS) in an array format enabled spatial separation of LAMP amplicons in a multiplexed configuration. Important parameters such as length of the SS primers, length of the primer-binding region, the effect of surface density of immobilized SS primers, and cross-reactivity among the primers of different targets were iteratively tested and optimized. With the combination of SP-LAMP and SAF techniques, it was possible to detect multiple pathogens that include Salmonella spp, Campylobater spp., Campylobacter coli, Campylobacter jejuni, avian influenza virus (AIV), and pan avian internal control (IC) under singleplex conditions. The multiplexing capacity of the SP-LAMP was demonstrated using AIV and IC with promising results. The success of SP-LAMP has opened a promising direction toward the development of a multiplex POC system for rapid detection of multiple pathogens.
Trends in adapting new-generation biosensors for rapid detection of infectious diseases are gaining interest in the field of clinical diagnostics and point-of-care (POC) industry. Advanced molecular amplification techniques, next-generation affinity probes such as aptamers, and unique optical features of nanoparticles such as quantum dots, graphene, palladium, silver, and gold nanoparticles have significant impact on the development of such biosensors. Among several nucleic acid amplification techniques, loop-mediated isothermal amplification (LAMP) has proven to be a promising technique for rapid online detection because of its unique features that suit ideal for POC applications. Similarly, aptamers have widespread applications in the POC industry as they provide remarkable flexibility and convenience in engineering the desired structures. POC biosensor development primarily relies on precise incorporation, integration, and streamlining of all the necessary steps from sample preparation to detection and analysis. Realizing high accuracy and sensitivity in a time-saving and cost-effective manner has always been the pre-requisite and customer interest. With this perspective, this book chapter details the most important factors that play a role in interfacing new-generation molecular techniques, the state-of-the-art sample preparation, and pathogen concentration strategies with robust sensing platforms for POC diagnostic applications. We will focus mainly on the principal factors governing analytical precision and robustness of new-generation molecular techniques such as direct PCR, solid-phase PCR (SP-PCR), and LAMP in POC biosensors for pathogen detection. The role of aptamers in pathogen concentration and LAMP as an ideal nucleic acid amplification technique for POC biosensor development has been given priority.
The COVID-19 pandemic emphasized the importance of rapid, portable, and on-site testing technologies necessary for resource-limited settings for effective testing and screening to reduce spreading of the infection. Realizing this, we developed a fluorescence-based point-of-care (fPOC) detection system with real-time reverse transcriptase loop-mediated isothermal amplification for rapid and quantitative detection of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus. The system is built based on the Arduino platform compatible with commercially available open-source hardware–software and off-the-shelf electronic components. The fPOC system comprises of three main components: 1) an instrument with integrated heaters, 2) optical detection components, and 3) an injection-molded polymeric cartridge. The system was tested and experimentally proved to be able to use for fast detection of the SARS-CoV-2 virus in real-time in less than 30 min. Preliminary results of testing the performance of the fPOC revealed that the fPOC could detect the SARS-CoV-2 virus at a limit of detection (LOD 50% ) at two to three copies/microliter (15.36 copies/reaction), which was comparable to reactions run on a standard commercial thermocycler. The performance of the fPOC was evaluated with 12 SARS-CoV-2 clinical throat swab samples that included seven positive and five negative samples, as confirmed by reverse transcription–polymerase chain reaction. The fPOC showed 100% agreement with the commercial thermocycler. This simple design of the fPOC system demonstrates the potential to greatly enhance the practical applicability to develop a totally integrated point-of-care system for rapid on-site screening of the SARS-CoV-2 virus in the management of the pandemic.
Invasive non-typhoidal salmonellosis is gaining worldwide attention as an emerging disease cluster among bloodstream infections. The disease has the highest burden among immunocompromised and malnourished children in resource-limited areas due to poor access to reliable and rapid diagnostics. Point-of-care (POC) diagnostics are promising for use in such low infrastructure laboratory settings. However, there still remains a major challenge for POC testing to deal with the complexity of blood matrices in rapid detection of an extremely low concentration of blood-borne pathogens. In this work, the challenges were addressed by combining magnetic bead based pathogen concentration and Loop Mediated Isothermal Amplification (LAMP) technology. Sensitivity and performance of the combined approach were determined and compared with a direct PCR method. A direct visual detection strategy, adapted using SYTO-24 DNA intercalating dye, resulted in a limit of detection (LoD) as low as 14 CFU/mL in blood samples with a total analysis time of less than 2 h, including sample preparation. This approach has the potential for wide application as a high-throughput POC testing method to analyze pathogens in clinical, food, feed and environmental samples.
Loop-mediated isothermal amplification (LAMP) is being used as a robust rapid diagnostic tool to prevent the transmission of infectious diseases. However, carryover contamination of LAMP-amplified products originating from previous tests has been a problem in LAMP-based bio-analytical assays. In this study, we developed a Cod-uracil-DNA-glycosylase real-time reverse transcriptase LAMP assay (Cod-UNG-rRT-LAMP) for the elimination of carryover contamination and the rapid detection of SARS-CoV-2 in point-of-care (POC) testing. Using the Cod-UNG-rRT-LAMP assay, the SARS-CoV-2 virus could be detected as low as 2 copies/µl (8 copies/reaction) within 45 min of amplification and 2.63 ± 0.17 pg (equivalent to 2.296 × 109 copies) of contaminants per reaction could be eliminated. Analysis of clinical SARS-CoV-2 samples using the Cod-UNG-rRT-LAMP assay showed an excellent agreement with a relative accuracy of 98.2%, sensitivity of 97.1%, and specificity of 95.2% in comparison to rRT-PCR. The results obtained in this study clearly demonstrate the feasibility of the use of the Cod-UNG-rRT-LAMP assay for applications toward the POC diagnosis of SARS-CoV-2 and on-site testing of other pathogens.
"This commentary article focuses on early, onsite and rapid detection, such as point-of-care (POC) diagnostics of the SARS-CoV-2."
Avian influenza virus (AIV) outbreaks occur frequently worldwide, causing a potential public health risk and great economic losses to poultry industries. Considering the high mutation rate and frequent genetic reassortment between segments in the genome of AIVs, emerging new strains are a real threat that may infect and spread through the human population, causing a pandemic. Therefore, rapid AIV diagnostic tests are essential tools for surveillance and assessing virus spreading. Real-time reverse transcription PCR (rRT-PCR), targeting the matrix gene, is the main official standard test for AIV detection, but the method requires well-equipped laboratories. Reverse transcription Loop-Mediated Isothermal Amplification (RT-LAMP) has been reported as a rapid method and an alternative to PCR in pathogen detection. The high mutation rate in the AIV genome increases the risk of false negative in nucleic acid amplification methods for detection, such as PCR and LAMP, due to possible mismatched priming. In this study, we analyzed 800 matrix gene sequences of newly isolated AIV in the EU and designed a highly efficient LAMP primer set that covers all AIV subtypes. The designed LAMP primer set was optimized in real-time RT-LAMP (rRT-LAMP) assay. The rRT-LAMP assay detected AIV samples belonging to nine various subtypes with the specificity and sensitivity comparable to the official standard rRT-PCR assay. Further, a two-color visual detection RT-LAMP assay protocol was adapted with the aim to develop on-site diagnostic tests. The on-site testing successfully detected spiked AIV in birds oropharyngeal and cloacal swabs samples at a concentration as low as 100.8 EID50 per reaction within 30 minutes including sample preparation. The results revealed a potential of this newly developed rRT-LAMP assay to detect AIV in complex samples using a simple heat treatment step without the need for RNA extraction.
Concentration of pathogens directly from food samples by using magnetic beads is a potential strategy in the on site food sample analysis. In this study, magnetic beads, double modified with platinum/palladium nanoparticle (Pt/Pd NP) and DNA aptamer, is presented as catalytic nano-bioprobes for the on-site detection of Salmonella enterica serovar Typhimurium in food and fecal samples. Combination of the developed catalytic nano-bioprobes with loop mediated isothermal amplification (LAMP) enabled rapid detection of low levels of S. Typhimurium in food and chicken fecal samples without culture enrichment. S. Typhimurium-specific DNA aptamer immobilized on the magnetic bead could efficiently concentrate S. Typhimurium with a capturing efficiency higher than 76% in phosphate-buffered saline (PBS). Further, DNA-mediated inhibition of peroxidase-mimic activity of Pt/Pd NP in combination with LAMP was used as a unique approach to detect S. Typhimurium. With this unique approach, it was possible to capture and detect S. Typhimurium as low as 10-15 CFU/mL in chicken meat sample and 3-10 CFU/mL in both whole egg and chicken fecal samples within less than 3 h. Analysis of S. Typhimurium-spiked chicken meat, whole egg and chicken fecal materials have confirmed the precision of the method. A relative accuracy of 90% with an intra and inter assay precision of 8.36% and 9.92% respectively was achieved in the S. Typhimurium-spiked food samples. This unique approach has the potential for the integration in to Lab-on-a-chip based biosensors for on-site monitoring of foodborne pathogens in future.
The development of lab-on-a-chip technology and its applications in biochemical and biomedical analyses has, during the last two decades, led to the potential realisation of portable and on-site detection devices, the so-called point-of-care (PoC) detection systems. These are essentially cheap, easy-to-handle systems, offering rapid sample-to-answer results to non-technical operators. In this perspective, we do not review all the current advances of Lab-on-a-chip techniques for the realisation of PoC. Instead, we aim to provide insight into what we foresee as the three most important factors to play the essential roles for succeeding in making commercially viable PoC pathogen-detection devices. The three insights are namely: the utilizations of (i) disposable polymer (microfluidic) chips, (ii) the implementation of surface-bound (or solid-phase) nucleic-acid amplification techniques and (iii) relying (more) on open-source hardware and software. (C) 2020 The Author(s). Published by Elsevier B.V.
The development of lab-on-a-chip technology and its applications in biochemical and biomedical analyses has, during the last two decades, led to the potential realisation of portable and on-site detection devices, the so-called point-of-care (PoC) detection systems. These are essentially cheap, easy-to-handle systems, offering rapid sample-to-answer results to non-technical operators. In this perspective, we do not review all the current advances of Lab-on-a-chip techniques for the realisation of PoC. Instead, we aim to provide insight into what we foresee as the three most important factors to play the essential roles for succeeding in making commercially viable PoC pathogen-detection devices. The three insights are namely: the utilizations of (i) disposable polymer (microfluidic) chips, (ii) the implementation of surface-bound (or solid-phase) nucleic-acid amplification techniques and (iii) relying (more) on open-source hardware and software.
Bloodstream infections and invasive nontyphoidal Salmonellosis in particular remain a major health and economic burden worldwide. The complexity of blood matrixes along with extremely low concentration of pathogens in blood poses a great challenge for rapid and ultrasensitive detection. Sample preparation has been the critical step that should provide blood-matrix-free sample with the targeted pathogen in the highest possible concentration. In this work, we addressed this challenge by combining magnetic-bead-based pathogen concentration and solid-phase PCR (SP-PCR). The SP-PCR performed on a supercritical angle fluorescence (SAF) microlens array embedded in a microchip enabled quick and accurate detection of low levels of Salmonella enterica serovar typhimurium and enteritidis in blood samples without culture enrichment. Protein AG-magnetic beads immobilized with antisalmonella antibody could efficiently concentrate both Salmonella serovars with a capturing efficiency >95%. Higher tolerance of Phusion hot start DNA polymerase to PCR inhibitors and its compatibility with protein AG-magnetic beads allowed the integration of SP-PCR. Analysis of Salmonella-spiked blood samples with the SP-PCR resulted in a limit of detection (LoD) as low as 86 CFU/mL and 94 CFU/mL for S. typhimurium and S. enteritidis, respectively, that could be attributed to the high fluorescence collection efficiency of the SAF microlens array. These combinations reduced the duration of analysis to less than 3 h including sample preparation. This platform has the potential for wide application as a high-throughput biosensor to analyze pathogens in clinical, food, and environmental samples.
We believe a point-of-care (PoC) device for the rapid detection of the 2019 novel Coronavirus (SARS-CoV-2) is crucial and urgently needed. With this perspective, we give suggestions regarding a potential candidate for the rapid detection of the coronavirus disease 2019 (COVID-19), as well as factors for the preparedness and response to the outbreak of the COVID-19.
The volume of point of care (POC) testing continues to grow steadily due to the increased availability of easy-to-use devices, thus making it possible to deliver less costly care closer to the patient site in a shorter time relative to the central laboratory services. A novel class of molecules called microRNAs have recently gained attention in healthcare management for their potential as biomarkers for human diseases. The increasing interest of miRNAs in clinical practice has led to an unmet need for assays that can rapidly and accurately measure miRNAs at the POC. However, the most widely used methods for analyzing miRNAs, including Northern blot-based platforms, in situ hybridization, reverse transcription qPCR, microarray, and next-generation sequencing, are still far from being used as ideal POC diagnostic tools, due to considerable time, expertize required for sample preparation, and in terms of miniaturizations making them suitable platforms for centralized labs. In this review, we highlight various existing and upcoming technologies for miRNA amplification and detection with a particular emphasis on the POC testing industries. The review summarizes different miRNA targets and signals amplification-based assays, from conventional methods to alternative technologies, such as isothermal amplification, paper-based, oligonucleotide-templated reaction, nanobead-based, electrochemical signaling- based, and microfluidic chip-based strategies. Based on critical analysis of these technologies, the possibilities and feasibilities for further development of POC testing for miRNA diagnostics are addressed and discussed.
Campylobacteriosis is one of the most common foodborne diseases worldwide. Two Campylobacter species - C. jejuni and C. coli in poultry and poultry products are considered to be the main source of human campylobacteriosis. Therefore, studying Campylobacter status in poultry flocks is needed to prevent transmission of disease and reduce human risk, health cost, and economic losses. In this study, we adapted and used a Loop-Mediated Isothermal Amplification (LAMP) assay for specific, sensitive, simple and cost-effective rapid detection of C. jejuni and C. coli in the poultry production chain. Amplified LAMP products were detected using a small, low-cost portable commercial blue LED transilluminator and a direct visual detection strategy was demonstrated. By using optimized conditions for amplification a limit of detection (LOD) of 50 CFU/ml was achieved for testing of C. jejuni and C. coli in spiked chicken feces without enrichment. The method took 60-70 min from receiving the samples to the final results (including 30 min for amplification). The optimized LAMP showed a relative accuracy of 98.4%, a specificity of 97.9%, and a sensitivity of 100% in comparison to real-time PCR method. Cohen's kappa index also showed an excellent agreement (0.94) between the two methods. The results showed that the method is specific, sensitive and is suitable to develop for rapid detection of Campylobacter spp. at poultry production.
Foodborne salmonellosis remains a major economic burden worldwide and particularly for food industries. The diverse and complexity of food matrices pose great challenges for rapid and ultra-sensitive detection of Salmonella in food samples. In this study, combination of pathogen pre-concentration with rapid molecular identification is presented to overcome these challenges. This combination enabled effective real-time PCR detection of low levels of Salmonella enterica serovar Typhimurium without culture enrichment. Anti-salmonella antibody, immobilized on protein AG-magnetic beads, could efficiently concentrate Salmonella Typhimurium with a capturing efficiency of 95%. In the direct PCR, a strong linear relationship between bacteria concentration and the number of cycles was observed with a relative PCR efficiency of ∼92% resulting in a limit of detection (LoD) of ∼2 CFU/mL. Analysis of spiked food samples that include vegetable salad, egg yolk, egg white, whole egg and minced pork meat has validated the precision of the method. A relative accuracy of 98.3% with a sensitivity of 91.6% and specificity of 100% was achieved in the Salmonella spiked food samples. The use of a Phusion hot start DNA polymerase with a high tolerance to possible PCR inhibitors allowed the integration of direct PCR, and thereby reducing the duration of analysis to less than 3 h. The Cohen's kappa index showed excellent agreement (0.88) signifying the capability of this method to overcome the food matrix effects in rapid and ultra-sensitive detection of Salmonella in food. This approach may lay a future platform for the integration into a Lab-on-a-chip system for online monitoring of foodborne pathogens.
This protocol provides insights into the rapid, low-cost, and largescale fabrication of polymer microfluidic chips containing three-dimensional microstructures used in point-of-care devices for applications such as detection of pathogens via molecular diagnostic methods. The details of the fabrication methods are described in this paper. This study offers suggestions for researchers and experimentalists, both at university laboratories and in industrial companies, to prevent doom fabrication issues. For a demonstration of bio-application in point-of-care testing, the 3D microarrays fabricated are then employed in multiplexed detection of Salmonella (Salmonella Typhimurium and Salmonella Enteritidis), based on a molecular detection technique called solid-phase polymerase chain reaction (SP-PCR).