ABSTRACT Wastewater-based epidemiology is a powerful tool for monitoring the emergence and spread of viral pathogens at the population scale. Typical polymerase chain reaction (PCR)-based methods of quantitative and genomic monitoring of viruses in wastewater provide high sensitivity and specificity. However, these methods are limited to the surveillance of target viruses in a single assay and require prior knowledge of the target genome(s). Metagenomic sequencing methods may represent a target-agnostic approach to viral wastewater monitoring, allowing for the detection of a broad range of target viruses, including potentially novel and emerging pathogens. In this study, targeted and untargeted metagenomic sequencing methods were compared with tiled-PCR sequencing for the detection and genotyping of viral pathogens in wastewater samples. Deep shotgun metagenomic sequencing was unable to generate sufficient genome coverage of human pathogenic viruses for robust genomic epidemiology, with samples dominated by bacteria. Hybrid-capture enrichment of shotgun libraries for respiratory viruses led to significant increases in genome coverage for a range of targets. Tiled-PCR sequencing led to further improvements in genome coverage compared to hybrid capture for severe acute respiratory syndrome coronavirus 2, enterovirus D68, norovirus GII, and human adenovirus F41 in wastewater samples. In conclusion, untargeted shotgun sequencing was unsuitable for genomic monitoring of the low virus concentrations in wastewater samples analyzed in this study. Hybrid-capture enrichment represented a viable method for simultaneous genomic epidemiology of a range of viral pathogens, while tiled-PCR sequencing provided the optimal genome coverage for individual viruses with the minimum sequencing depth. IMPORTANCE Most public health initiatives that monitor viruses in wastewater have utilized quantitative polymerase chain reaction (PCR) and whole genome PCR sequencing, mirroring techniques used for viral epidemiology in individuals. These techniques require prior knowledge of the target viral genome and are limited to monitoring individual or small groups of viruses. Metagenomic sequencing may offer an alternative strategy for monitoring a broad spectrum of viruses in wastewater, including novel and emerging pathogens. In this study, while amplicon sequencing gave high viral genome coverage, untargeted shotgun sequencing of total nucleic acid samples was unable to detect human pathogenic viruses with enough sensitivity for use in genomic epidemiology. Enrichment of shotgun libraries for respiratory viruses using hybrid-capture technology provided genotypic information on a range of viruses simultaneously, indicating strong potential for wastewater surveillance. This type of targeted metagenomics could be used for monitoring diverse targets, such as pathogens or antimicrobial resistance genes, in environmental samples.
The 2022 multicountry mpox outbreak concurrent with the ongoing Coronavirus Disease 2019 (COVID-19) pandemic further highlighted the need for genomic surveillance and rapid pathogen whole-genome sequencing. While metagenomic sequencing approaches have been used to sequence many of the early mpox infections, these methods are resource intensive and require samples with high viral DNA concentrations. Given the atypical clinical presentation of cases associated with the outbreak and uncertainty regarding viral load across both the course of infection and anatomical body sites, there was an urgent need for a more sensitive and broadly applicable sequencing approach. Highly multiplexed amplicon-based sequencing (PrimalSeq) was initially developed for sequencing of Zika virus, and later adapted as the main sequencing approach for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2). Here, we used PrimalScheme to develop a primer scheme for human monkeypox virus that can be used with many sequencing and bioinformatics pipelines implemented in public health laboratories during the COVID-19 pandemic. We sequenced clinical specimens that tested presumptively positive for human monkeypox virus with amplicon-based and metagenomic sequencing approaches. We found notably higher genome coverage across the virus genome, with minimal amplicon drop-outs, in using the amplicon-based sequencing approach, particularly in higher PCR cycle threshold (Ct) (lower DNA titer) samples. Further testing demonstrated that Ct value correlated with the number of sequencing reads and influenced the percent genome coverage. To maximize genome coverage when resources are limited, we recommend selecting samples with a PCR Ct below 31 Ct and generating 1 million sequencing reads per sample. To support national and international public health genomic surveillance efforts, we sent out primer pool aliquots to 10 laboratories across the United States, United Kingdom, Brazil, and Portugal. These public health laboratories successfully implemented the human monkeypox virus primer scheme in various amplicon sequencing workflows and with different sample types across a range of Ct values. Thus, we show that amplicon-based sequencing can provide a rapidly deployable, cost-effective, and flexible approach to pathogen whole-genome sequencing in response to newly emerging pathogens. Importantly, through the implementation of our primer scheme into existing SARS-CoV-2 workflows and across a range of sample types and sequencing platforms, we further demonstrate the potential of this approach for rapid outbreak response.