The discovery of a fair sample of Earth-analogues (Earth 2.0's), i.e. rocky, Earth-mass exoplanets orbiting a Solartype star in that host star's habitable zone, and a subsequent search of evidence of bioactivity on those Earth 2.0's by the detection of biogenically produced molecules in those exoplanetary atmospheres, are two of the most urgent observational programs in astrophysics and science in general. To identify an Earth 2.0, it is necessary to measure the reflex motion radial velocity amplitude of the host star at the 10 cm/sec level, a precision considerably below that which is currently achievable with existing instruments. The follow-on project to search for the biomarkers in an Earth 2.0's atmosphere may require an effective planet/star contrast of 10-10, again well below the currently achievable level. In this paper, we discuss technical innovations in the implementation of the GMT-Consortium Large Earth Finder (G-CLEF) spectrograph that will enable these observational objectives. We discuss plans to operate G-CLEF at the Magellan Clay telescope with the MagAO-X adaptive optics system and subsequently with GMagAO-X at the Giant Magellan Telescope (GMT).
For the fifth Sloan Digital Sky Survey, SDSS-V, we moved one of the two SDSS BOSS spectrographs from Apache Point Observatory in New Mexico to Las Campanas Observatory in Chile, giving us dual-hemisphere coverage. Modifications for connecting to a new robotic fiber positioner included replacing the old fiber slit with a monolithic fiber slit made of a precision-machined glass mount presenting 528 fibers. To construct this slit, V-grooves were cut into a borosilicate glass substrate and fibers were glued into them under a cover plate. This glass slit was then attached to an Alloy 39 (steel) flexure, which in turn was affixed to a thin slit plate made of cast aluminum for insertion into the spectrograph. Because our existing spare parts inventory would not support two distant locations, and because many parts were no longer manufactured, some spectrograph subsystems were replaced with new components or designs.
We describe the Sloan Digital Sky Survey Local Volume Mapper Instrument (LVM-I) construction, testing, and initial performance. The facility is designed to produce the first integral map of thousands of degrees of the Southern sky. The map will cover spectra from bluer than [O II] to 980 nm with a dispersion of over R =Delta lambda/lambda > 4, 000 at Ha wavelength. Each spaxel will have a pitch of similar to 35 '', and the survey will be conducted using four integral field units (IFUs) with an instantaneous field of view of 530 arcmin(2). The LVM facility is designed to achieve the required sub-Rayleigh spectroscopy over large sky areas with outstanding spectrophotometric accuracy and precision. LVM-I is designed to produce this unique dataset using four siderostats on commercial mounts. The four beams are fed into 16-cm-diameter f/11.4 apochromatic objectives, and the sky is derotated with K mirrors. These telescopes produce an image of the field onto both guider cameras and a lenslet array. The array reimages the field at f/3.7 onto 107-micron-diameter fibers. Blue throughput is maximized with a short 18.5-m fiber run from the IFUs to the spectrographs. The fibers are reconfigured inside a splicing box to distribute the fibers from the four telescopes to three spectrographs. The spectrographs are near-copies of the Dark Energy Survey three-band f/1.7 spectrographs, which deliver sharp images over the entire chromatic range. Nine STA charge-coupled devices (CCDs), cooled with liquid-nitrogen dewars, are used for the survey. The LVM-I is controlled with custom Python software and distributed over various computers using power-over-ethernet networking. The system is housed in a custom enclosure with a roll-off roof to grant access to the sky. The enclosure allows all four telescopes to point all over the sky and measure the transmissivity of the atmosphere and the sky background. Some of the first-light data products are highlighted here.
The GMT-Consortium Large Earth Finder (G-CLEF) is the first instrument for the Giant Magellan Telescope (GMT). G-CLEF is a fiber feed, optical band echelle spectrograph that is capable of extremely precise radial velocity measurement. G-CLEF Flexure Control Camera (FCC) is included as a part in G-CLEF Front End Assembly (GCFEA), which monitors the field images focused on a fiber mirror to control the flexure and the focus errors within GCFEA. FCC consists of an optical bench on which five optical components are installed. The order of the optical train is: a collimator, neutral density filters, a focus analyzer, a reimager and a detector (Andor iKon-L 936 CCD camera). The collimator consists of a triplet lens and receives the beam reflected by a fiber mirror. The neutral density filters make it possible a broad range star brightness as a target or a guide. The focus analyzer is used to measure a focus offset. The reimager focuses the beam from the collimator onto the CCD detector focal plane. The detector module includes a linear translator and a field de-rotator. We performed thermoelastic stress analysis for lenses and their mounts to confirm the physical safety of the lens materials. We also conducted the global structure analysis for various gravitational orientations to verify the image stability requirement during the operation of the telescope and the instrument. In this article, we present the opto-mechanical detailed design of G-CLEF FCC and describe the consequence of the numerical finite element analyses for the design.
We describe the development status of the first-generation science instruments for the Giant Magellan Telescope (GMT). The first-generation suite includes two infrared and two visible light spectrographs that together will deliver from wide-band imaging to R~200,000 spectroscopy at wavelengths from 0.3 to 5 µm. All four instruments are designed for use with diffraction limited or ground-layer adaptive optics modes. G-CLEF, a visible light echelle designed for broad scientific use and for precision radial velocity measurements, is in fabrication. The other three (GMACS, a wide field multi-object spectrograph; GMTNIRS, a near- to thermal-infrared echelle spectrograph utilizing silicon immersion gratings; and GMTIFS, a near-infrared imager and integral field spectrograph) are in Preliminary Design. The first-generation suite also includes a robotic fiber-feed system called MANIFEST, which enables spectroscopy over the 20 arcmin field of view of the telescope with custom fibers for G-CLEF, GMACS, and GMTNIRS. An additional facility instrument, GMagAO-X, is being developed to provide high-contrast imaging at visible and near-infrared wavelengths and is in Preliminary Design. We also discuss the visible and infrared cameras (called ComCam and AOTC, respectively) that will be used for alignment, verification, and commissioning of the active and adaptive optics modes of the telescope and enable early science activities.
This paper describes the deployment of the GMT-Consortium Large Earth Finder (G-CLEF) at the Clay telescope, one of the two Magellan telescopes, in late 2025, moving to the GMT in 2030. G-CLEF is a fiber-fed, ultra-high stability optical band echelle spectrograph designed for extremely precise stellar radial velocity measurement. On the Magellan Clay telescope, G-CLEF will take spectra with resolution up to ~300,000, fully resolving molecular spectral features and opening totally new discovery space for exoplanet atmosphere composition studies. G@M will also be coupled to the Magellan extreme adaptive optics facility, MagAO-X which will allow it to spatially resolve several exoplanets from their host stars. We provide a system description of the G@M instrument as it will be configured at Magellan. A top-level review of optomechanics, electronics and control systems follows, as well as a description of several risk-reduction exercises the team has undertaken.
The GMT-Consortium Large Earth Finder (G-CLEF) is a fiber-fed, optical echelle spectrograph that will be a first light instrument for the Giant Magellan Telescope (GMT). G-CLEF is a general-purpose echelle spectrograph with precision radial velocity (PRV) capability. The radial velocity (RV) precision goal of G-CLEF is 10 cm/sec; necessary for detection of Earth-sized exoplanets orbiting Solar-type stars in their habitable zone. This imposes challenging stability requirements on the optical mounts and spectrograph support structures especially when considering the instrument's operational environment. G-CLEF's accuracy will be influenced by thermal effects, ambient air pressure, vibration, and micro gravity-vector variations caused by normal telescope slewing. The design and fabrication schedule for the G-CLEF spectrograph and ancillary systems will lead the GMT telescope by approximately 5 years, therefore, we will design and build an interim installation configuration for G-CLEF at Magellan's 6.5m telescopes. This will allow us to complete and commission the spectrograph. During this period, we will collect at least 5 years of data at Magellan from roughly 2025 to 2030. We will also optimize major subsystems including; spectrograph optics and mechanics, vacuum systems, thermal control, and vibration isolation. G-CLEF completed its Critical Design Phase for the GMT configuration in 2018. In this paper, we provide an update on the G-CLEF spectrograph's opto-mechanical design, including the GMT front end assembly. We also provide an update on our current fabrication status including procurement of camera optics, reflective optics, carbon-fiber optical bench, camera optical mounts, and vacuum chamber assembly. We also discuss adaptations required to support the interim deployment at Magellan.
The Giant Magellan Telescope (GMT) Commissioning Camera (ComCam) is an all-refractive, focal reducing camera intended for the evaluation of telescope performance in both natural seeing and ground layer adaptive optics modes across a six arcminute field of view. As the first purpose-built, large imager for the GMT, it also provides unique public outreach functions and scientific research opportunities by enabling both narrowband and broadband imaging and photometric measurements at wavelengths between 360 and 950 nm. In addition to a discrete set of narrowband and broadband filters, inclusion of a deployable Fabry-Perot etalon will greatly enhance ComCam’s capabilities. With an image scale of 0.06 arcseconds per pixel, ComCam will be able to take full advantage of the GMT’s GLAO-corrected image quality under the best predicted conditions. ComCam has undergone a conceptual design review and is now under development in the preliminary design phase. Instrumental first light will be concurrent with that of the GMT.
We describe the design and performance of the near-infrared (1.51-1.70 mu m), fiber-fed, multi-object (300 fibers), high resolution (R = lambda/Delta lambda similar to 22,500) spectrograph built for the Apache Point Observatory Galactic Evolution Experiment (APOGEE). APOGEE is a survey of similar to 10(5) red giant stars that systematically sampled all Milky Way populations (bulge, disk, and halo) to study the Galaxy's chemical and kinematical history. It was part of the Sloan Digital Sky Survey III (SDSS-III) from 2011 to 2014 using the 2.5 m Sloan Foundation Telescope at Apache Point Observatory, New Mexico. The APOGEE-2 survey is now using the spectrograph as part of SDSS-IV, as well as a second spectrograph, a close copy of the first, operating at the 2.5 m du Pont Telescope at Las Campanas Observatory in Chile. Although several fiber-fed, multi-object, high resolution spectrographs have been built for visual wavelength spectroscopy, the APOGEE spectrograph is one of the first such instruments built for observations in the near-infrared. The instrument's successful development was enabled by several key innovations, including a "gang connector" to allow simultaneous connections of 300 fibers; hermetically sealed feedthroughs to allow fibers to pass through the cryostat wall continuously; the first cryogenically deployed mosaic volume phase holographic grating; and a large refractive camera that includes mono-crystalline silicon and fused silica elements with diameters as large as similar to 400 mm. This paper contains a comprehensive description of all aspects of the instrument including the fiber system, optics and opto-mechanics, detector arrays, mechanics and cryogenics, instrument control, calibration system, optical performance and stability, lessons learned, and design changes for the second instrument.
The GMT-Consortium Large Earth Finder (G-CLEF) is one of the first instrument for the Giant Magellan Telescope (GMT). The G-CLEF is a fiber fed, optical band echelle spectrograph that is capable of extremely precise radial velocity measurement. The G-CLEF Flexure Control Camera (FCC) is included as a part in the G-CLEF Front End Assembly (GCFEA), which monitors the field images focused on a fiber mirror to control the flexure and the focus errors within the GCFEA. The five optical components constituting the FCC are aligned on a common optical bench. The order of the optical train is: a collimator, neutral density filters, a focus analyzer, a reimaging camera barrel, and a detector module. The collimator receives the beam reflected by the fiber mirror and consists of a triplet lens. The neutral density filters are located just after the collimator to make it possible a broad range star brightness as a target or a guide. The tent prism focus analyzer is positioned at a pupil produced by the collimator and is used to measure a focus offset. The reimaging camera barrel includes two pairs of doublet lenses to focus the beam onto the CCD focal plane. The detector module is composed of a linear translator and a field de-rotator. In this article, we present the optical and mechanical detailed designs of the G-CLEF FCC.
The GMT-Consortium Large Earth Finder (G-CLEF) will be part of the first generation instrumentation suite for the Giant Magellan Telescope (GMT). G-CLEF is a general purpose echelle spectrograph operating in the optical passband with precision radial velocity (PRV) capability. The measurement precision goal of G-CLEF is 10 cm/sec; necessary for the detection of Earth analogues. This goal imposes challenging stability requirements on the optical mounts and spectrograph support structures especially when considering the instrument’s operational environment. G-CLEF’s accuracy will be influenced by changes in temperature and ambient air pressure, vibration, and micro gravity-vector variations caused by normal telescope motions. For these reasons we have chosen to enclose G-CLEF’s spectrograph in a wellinsulated, vibration-isolated vacuum chamber in a gravity invariant location on GMT’s azimuth platform. Additional design constraints posed by the GMT telescope include; a limited space envelope, a thermal leakage ceiling, and a maximum weight allowance. Other factors, such as manufacturability, serviceability, available technology, and budget are also significant design drivers. G-CLEF will complete its Critical Design phase in mid-2018. In this paper, we discuss the design of GCLEF’s optical mounts and support structures including the choice of a low-CTE carbon-fiber optical bench. We discuss the vacuum chamber and vacuum systems. We discuss the design of G-CLEF’s insulated enclosure and thermal control systems which simultaneously maintain the spectrograph at milli-Kelvin level stability and limit thermal leakage into the telescope dome. Also discussed are micro gravity-vector variations caused by normal telescope slewing, their uncorrected influence on image motion, and how they are dealt with in the design. We discuss G-CLEF’s front-end assembly and fiber-feed system as well as other interface, integration and servicing challenges presented by the telescope, enclosure, and neighboring instrumentation. This work has been supported by the GMTO Corporation, a non-profit organization operated on behalf of an international consortium of universities and institutions: Arizona State University, Astronomy Australia Ltd, the Australian National University, the Carnegie Institution for Science, Harvard University, the Korea Astronomy and Space Science Institute, the São Paulo Research Foundation, the Smithsonian Institution, the University of Texas at Austin, Texas AM University, the University of Arizona, and the University of Chicago.
The GMT-Consortium Large Earth Finder (G-CLEF) will be part of the first generation instrumentation suite for the Giant Magellan Telescope (GMT). G-CLEF will be a general purpose optical passband echelle spectrograph with a precision radial velocity (PRV) capability of 10 cm/sec, a requirement necessary for the detection of Earth analogues. The instrument will be particularly sensitive to thermal effects and the necessary stability cannot be achieved through the use of low CTE materials alone. It is the combination of low CTE materials and exquisite thermal control which will enable the instrument to achieve its precision requirements. G-CLEF will complete its Critical Design phase in mid-2018. In this paper, we discuss the precision thermal control systems which enable milli-Kelvin-level stability of the spectrograph and its red and blue focal planes. The measurement electronics and thermal control strategies used in the spectrograph are described. Of particular importance is the development of a continuous LN2 flow cryo-cooler system used to maintain the focal planes at stable cryogenic operational temperatures. This system has been validated with a prototyping effort completed during the instrument's design phase. We also review G-CLEF's insulated enclosure which simultaneously maintains the spectrograph a stable temperature and limits the maximum thermal leakage into the telescope dome. This work has been supported by the GMTO Corporation, a non-profit organization operated on behalf of an international consortium of universities and institutions: Arizona State University, Astronomy Australia Ltd, the Australian National University, the Carnegie Institution for Science, Harvard University, the Korea Astronomy and Space Science Institute, the Sao Paulo Research Foundation, the Smithsonian Institution, the University of Texas at Austin, Texas A&M University, the University of Arizona, and the University of Chicago.
The GMT-Consortium Large Earth Finder (G-CLEF) is an instrument that is being designed to exceed the state-of-the-art radial velocity (RV) precision achievable with the current generation of stellar velocimeters. It is simultaneously being designed to enable a wide range of scientific programs, prominently by operating to blue wavelengths (< 3500Å). G-CLEF will be the first light facility instrument on the Giant Magellan Telescope (GMT) when the GMT is commissioned in 2023. G-CLEF is a fiber-fed, vacuum-enclosed spectrograph with an asymmetric white pupil echelle design. We discuss several innovative structural, optical and control system features that differentiate G-CLEF from previous precision RV instruments.
The GMT-Consortium Large Earth Finder (G-CLEF) is an echelle spectrograph with precision radial velocity (PRV) capability that will be a first light instrument for the Giant Magellan Telescope (GMT). G-CLEF has a PRV precision goal of 40 cm/sec (10 cm/s for multiple measurements) to enable detection of Earth-like exoplanets in the habitable zones of sun-like stars1. This precision is a primary driver of G-CLEF’s structural design. Extreme stability is necessary to minimize image motions at the CCD detectors. Minute changes in temperature, pressure, and acceleration environments cause structural deformations, inducing image motions which degrade PRV precision. The instrument’s structural design will ensure that the PRV goal is achieved under the environments G-CLEF will be subjected to as installed on the GMT azimuth platform, including: Millikelvin (0.001 °K) thermal soaks and gradients 10 millibar changes in ambient pressure Changes in acceleration due to instrument tip/tilt and telescope slewing Carbon fiber/cyanate composite was selected for the optical bench structure in order to meet performance goals. Low coefficient of thermal expansion (CTE) and high stiffness-to-weight are key features of the composite optical bench design. Manufacturability and serviceability of the instrument are also drivers of the design. In this paper, we discuss analyses leading to technical choices made to minimize G-CLEF’s sensitivity to changing environments. Finite element analysis (FEA) and image motion sensitivity studies were conducted to determine PRV performance under operational environments. We discuss the design of the optical bench structure to optimize stiffness-to-weight and minimize deformations due to inertial and pressure effects. We also discuss quasi-kinematic mounting of optical elements and assemblies, and optimization of these to ensure minimal image motion under thermal, pressure, and inertial loads expected during PRV observations.
The GMT-Consortium Large Earth Finder (G-CLEF) is the very first light instrument of the Giant Magellan Telescope (GMT). The G-CLEF is a fiber feed, optical band echelle spectrograph that is capable of extremely precise radial velocity measurement. KASI (Korea Astronomy and Space Science Institute) is responsible for Flexure Control Camera (FCC) included in the G-CLEF Front End Assembly (GCFEA). The FCC is a kind of guide camera, which monitors the field images focused on a fiber mirror to control the flexure and the focus errors within the GCFEA. The FCC consists of five optical components: a collimator including triple lenses for producing a pupil, neutral density filters allowing us to use much brighter star as a target or a guide, a tent prism as a focus analyzer for measuring the focus offset at the fiber mirror, a reimaging camera with three pair of lenses for focusing the beam on a CCD focal plane, and a CCD detector for capturing the image on the fiber mirror. In this article, we present the optical and mechanical FCC designs which have been modified after the PDR in April 2015.
The GMT-Consortium Large Earth Finder (G-CLEF) is a fiber-fed, optical echelle spectrograph selected as the first light instrument for the Giant Magellan Telescope (GMT) now under construction at the Las Campanas Observatory in Chile. G-CLEF has been designed to be a general-purpose echelle spectrograph with precision radial velocity (PRV) capability for exoplanet detection. The radial velocity (RV) precision goal of G-CLEF is 10 cm/sec, necessary for detection of Earth-sized exoplanets. This goal imposes challenging stability requirements on the optical mounts and the overall spectrograph support structures especially when considering the instrument’s operational environment. The accuracy of G-CLEF’s PRV measurements will be influenced by minute changes in temperature and ambient air pressure as well as vibrations and micro gravity-vector variations caused by normal telescope slewing. For these reasons we have chosen to enclose G-CLEF’s spectrograph in a well-insulated, vibration isolated vacuum chamber in a gravity invariant location on GMT’s azimuth platform. Additional design constraints posed by the GMT telescope include: a limited space envelope, a thermal emission ceiling, and a maximum weight allowance. Other factors, such as manufacturability, serviceability, available technology and budget are also significant design drivers. All of the above considerations must be managed while ensuring performance requirements are achieved. In this paper, we discuss the design of G-CLEF’s optical mounts and support structures including the choice of a low coefficient of thermal expansion (CTE) carbon-fiber optical bench to minimize the system’s sensitivity to thermal soaks and gradients. We discuss design choices made to the vacuum chamber geared towards minimize the influence of daily ambient pressure variations on image motion during observation. We discuss the design of G-CLEF’s insulated enclosure and thermal control systems which will maintain the spectrograph at milli-Kelvin level stability while simultaneously limiting thermal emissions into the telescope dome. Also discussed are micro gravity-vector variations caused by normal telescope slewing, their uncorrected influence on image motion, and how they are dealt with in the design. Finally, we discuss G-CLEF’s front-end assembly and fiber-feed system as well as other interface challenges presented by the telescope, enclosure and neighboring instrumentation.
Instrument development for the 24m Giant Magellan Telescope (GMT) is described: current activities, progress, status, and schedule. One instrument team has completed its preliminary design and is currently beginning its final design (GCLEF, an optical 350-950 nm, high-resolution and precision radial velocity echelle spectrograph). A second instrument team is in its conceptual design phase (GMACS, an optical 350-950 nm, medium resolution, 6-10 arcmin field, multi-object spectrograph). A third instrument team is midway through its preliminary design phase (GMTIFS, a near-IR YJHK diffraction-limited imager/integral-field-spectrograph), focused on risk reduction prototyping and design optimization. A fourth instrument team is currently fabricating the 5 silicon immersion gratings needed to begin its preliminary design phase (GMTNIRS, a simultaneous JHKLM high-resolution, AO-fed, echelle spectrograph). And, another instrument team is focusing on technical development and prototyping (MANIFEST, a facility robotic, multifiber feed, with a 20 arcmin field of view). In addition, a medium-field (6 arcmin, 0.06 arcsec/pix) optical imager will support telescope and AO commissioning activities, and will excel at narrow-band imaging. In the spirit of advancing synergies with other groups, the challenges of running an ELT instrument program and opportunities for cross-ELT collaborations are discussed.