In this work, Ti-316L stainless steel was produced, and its electrochemical behavior was characterized. Ti-steel alloys were produced using an induction furnace, by mixing commercial Ti and 316L stainless steel. X-ray diffraction analyses showed the presence of both the materials, Ti and 316L, in the samples produced. The elemental composition of the materials was determined by optical emission spectroscopy and energy-dispersive spectroscopy, which showed similar quantities of both the elements. Both commercial 316L stainless steel and Ti-steel were studied in simulated biological fluid for imitate a like composition of body blood plasma. Electrochemical experiments conducted at 37 degrees C indicated the stable passive polarization behavior of the Ti-steel alloy. Furthermore, the electrochemical behavior of the 316L stainless steel was also analyzed for comparison purposes. Corrosion velocities were determined using the Tafel method and corrosion resistances were obtained using the electrochemical impedance spectroscopy. The Ti-steel exhibited better protection capacity, compared with the commercial 316L steel. The corrosion velocity and the passive current density of the Ti-steel alloy were lower than those exhibited by the 316L stainless steel.
A Fe32Cu64B4 (FeCuB) alloy was obtained by using an induction furnace under an argon atmosphere. Parameters suitable in the casting processes like voltage, temperature and cooling times were optimized. Once the FeCuB alloy was melted and solidified, X-ray diffraction (XRD) and surface morphology analysis were performed through optical and scanning electron microscopy (SEM-EDX). The results showed that complete diffusion of the precursor elements (Fe, Fe2B, Cu) requires thermal homogenization treatments (2 and 4 hours) at 750° as suggested from phase diagram of FeCuB simulation. The XRD analysis revealed that the primary crystallization consists of a mixture of the fcc-FeCuB (79%) and bcc-FeCuB (21%), with a = 3.62Å, spatial group Fm-3m and a = 2.86Å, spatial group Im-3m respectively. Micrographic images show an average grain distribution of ∼ 135µm. Finally, long times of homogenization (4 hours) allow a greater uniformity and redistribution of grain boundaries, resulting in the formation of an equiaxed grain structure in the alloy.
Resumen El propósito de esta investigación fue obtener Hidroxiapatita (HA) sintética de porosidad inducida con características osteoconductivas y mezclarlas con Proteínas Morfogenéticas Óseas (PMO) de características osteoinductivas, para que actuaran sinérgicamente y formaran un material de injerto biocompatible capaz de inducir la diferenciación de células locales a células formadoras de hueso y al mismo tiempo proporcionar un andamio osteoconductivo que dirigiera la formación de nuevo hueso, inmovilizara la molécula inductiva en el sitio de implantación por un tiempo suficiente para influenciar las células de respuesta y actuara como una barrera mecánica inicial para el crecimiento de tejido fibroso o la interposición de músculo en el defecto, para lograr finalmente el crecimiento de nuevo hueso en un tiempo considerablemente reducido y el total reemplazo del injerto por hueso enteramente autólogo. Para evaluar las características de este material, se utilizaron un total de 20 conejos machos raza Blanca de Nueva Zelanda, con un peso promedio de 2.2 kg y 75 días de edad, a los cuales se les creó un defecto óseo de forma rectangular de 8 mm de longitud y de profundidad igual a la corteza, en las diáfisis de las tibias, cara medial. En un miembro se implantaron placas de hidroxiapatita de 8mm de longitud y 2 mm de grosor; en el miembro contrario se implantó el compuesto HA-PMO. Se distribuyeron en 4 grupos de evaluación, a las 3, 6, 9 y 12 semanas de evolución, para valorar las características del implante; se realizó inferencia estadística de los datos tomados en el experimento, con un diseño en parcelas divididas siguiendo como estructura básica de aleatorización un DCA (Diseño Completamente al Azar), aplicando el factor t (tiempo) a las parcelas principales (conejos), y el factor i (tipo de implante) a las subparcelas (miembros posteriores). Palabras clave: fosfato de calcio, osteoconducción, osteoinducción. Summary The purpose of this research was to obtain synthetic Hydroxyapatite (HA) of induced porosity with osteoconductive characteristics and to mix it with Bone Morphogenetic Proteins (BMP) of osteoinductive characteristics, so they would act sinergically and would form a biocompatible graft material, able to induce differentiation of local cells to bone forming cells and at the same time supply an osteoconductive framework that lead to new bone formation, immobilize the inductive molecule at the implantation site for a sufficient time to influence the responding cells and would act as a mechanic initial barrier for fibrous tissue ingrowth or muscle interposition in the defect, thus finally achieve new bone formation in a substantial reduced time and graft total replacement by completely autologous bone. To evaluate the characteristics of this material, a total of 20 male New Zealand rabbits with an average weight of 2.2 kg and 75 days of age were used, a rectangular osseous defect of 8 mm of diameter with equal depth at the cortex was created in the medial face of the tibia diaphysis. In a hind limb, hydroxyapatite plates of 8 mm of large and 2 mm of thickness were implanted; in the opposite hind limb the compound HA-PMO was implanted. The rabbits were distributed in 4 evaluation groups at 3, 6, 9 and 12 weeks of evolution, to evaluate the characteristics of the implant. Statistical inference of the data taken on the experiment was performed, with divided parcels design, following as basic structure of aleatorization a Completely Random Design (CRD), applying t factor (time) to main parcels (rabbits), and i factor (graft material) to subparcels (posterior limbs). Key words: calcium phosphate, osteoconduction, osteoinduction.
Resumen Se presenta el procedimiento de obtención de hidroxiapatita (HA) sintética, Ca10(PO4)6(OH)2 a partir de fosfato de amonio y nitrato de calcio. Se incorporan fibras de celulosa, con el propósito de obtener una buena cristalización de HA y combustión de la celulosa formando un material poroso. Los análisis muestran alta proporción de HA y menor cantidad de fosfatos tetracálcico y tricálcico. Muestras de coral tratadas con fosfato de amonio (vía hidrotérmica) y muestras de coral precalentadas a 650 y 1000 °C, sumergidas en fosfato de amonio y posteriormente tratadas a 1050 °C (vía pirotérmica) fueron evaluadas mediante difracción de rayos X (DRX). Por la vía hidrotérmica no se obtuvo descomposición apreciable de la red de aragonito típica del coral y la vía pirotérmica propuesta, exhibe una baja o nula cantidad de HA. Los resultados indican que no es posible obtener HA a partir del coral bajo las condiciones experimentales evaluadas y que la coralina no se comporta como un material biocompatible para obtener regeneración ósea. Por último, al colocar injertos aloplásticos de HA, se observó buena integración de estos al hueso; los procesos de remodelación y reparación ósea fueron adecuados y evolucionaron de forma normal. Sin embargo, el grupo que recibió como injerto aloplástico la coralina presentó necrosis y lisis del hueso con marcada reacción inflamatoria. Palabras clave: fosfato de calcio, hidroxiapatita, injertos. Summary In this study we present the procedure to obtain synthetic hydroxyapatite (HA) from ammonium phosphate and calcium nitrate sources. Cellulose fibers were incorporated with the purpose to achieve a good crystallization of HA and combustion of the cellulose was performed in order to produce a porous-like material. The X-ray diffraction analysis (XRD) showed a high proportion of HA with small quantities of tricalcium and tetracalcium phosphates. Coral samples treated with ammonium phosphate by a hydrothermal procedure or coral samples pre-heated at 650 and 1000 °C submerged in ammonium phosphates and later on treated at 1050 °C by a pyrothermal procedure were also evaluated by XRD. The hydrothermal technique did not produce decomposition of the typical aragonite frame of the coral, whereas the pyrothermal technique did not produce any quantity of HA. Finally, a good integration of the HA was observed when HA was implanted to tibial bone in dogs; remodeling and reparation were optimal and evolved according to normal processes. However, the animals implanted with coralline showed necrosis, lysis and severe inflammatory reactions at the implantation sites. These results indicate that it is not possible obtain HA from coral under the experimental conditions here evaluated and that coralline did not behave as a good biocompatible material for implants. Keywords: calcium phosphate, hydroxyapatite, implants.
El objetivo del presente esbozo es hacer una sintesis historica de la evolucion del proceso de fundicion a la cera perdida desde sus origenes hasta la epoco actual, No se trata de hacer una descripcion detallada de los descubrimientos, sino de permitir una compresion general acerca de como el proceso ha permanecido constante, sin interrupcionen el tiempo. Pero notemos que desaparece en algunos lugares y aparece en otros desde hace 60 siglos hasta ahora. Por ello se trata de una de las tecnicas mas antiguas de la humanidad.
En Antioquia (Colombia), gran parte del recurso hidrico puede ser aprovechado por microcentrales electricas, en consecuencia, en la Universidad de Antioquia, se esta desarrollando un prototipo de turbina Pelton de 5 kW con destino a zonas no interconectadas del departamento. Los alabes de dichas turbinas estan sujetos a fuerzas mecanicas e hidrodinamicas y en especial, al efecto de cavitacion, por lo tanto, los materiales para dichos alabes deben resistir las solicitaciones ya mencionadas. En el presente articulo se evaluan cuatro materiales en condiciones aceleradas de cavitacion [2] (norma ASTM G32 [3]) y corrosion/erosion (POT TEST [4]): acero inoxidable martensitico (ASTM A746 grado CA6NM [1]) y bronces al niquel (C99350), aluminio (C95300) y silicio (SAE 68B). Ademas, se caracterizaran por los metodos de espectroscopia optica, microscopia optica y mediante propiedades mecanicas utilizando las normas ASTM E8 y ASTM E18. Los ensayos mostraron que hay una menor diferencia entre el acero inoxidable martensitico y los bronces al aluminio y al niquel en cavitacion, mientras que el bronce al silicio mostro el peor comportamiento en toda la serie evaluada, aunque muy buenos resultados bajo condiciones de corrosion/erosion.
The hydroxyapatite is the natural component of the human bone which can synthetically obtained by the reaction between calcium nitrate and ammonium phosphate keeping its bioactivity properties. Therefore, it can be chemically linked with the bone tissue. In this work microporous hydroxyapatite was obtained by a precipitation method, a polymer was added to generate the porosity and calcined at 750 and 850 °C. The synthesized hydroxyapatite (denominated HA UdeA) was compared with a commercial product. The samples were characterized by X Ray Diffraction (XRD), Fourier Transformed Infra Red (FTIR), Scanning Electronic Microscopy (SEM) and Thermoanalytical techniques (DTA – TGA). The results indicate that HA UdeA and the commercial product presented similar characteristics as crystalline structure, chemical composition and adsorption of species. Although some differences in shape and particle size were observed both ceramics can be used as implant biomaterials, for example in bone repair.
Los vidrios metalicos del tipo (Fe,Co)75Si15B10 se obtuvieron por solidificacion rapida utilizando la tecnica Melt spinning. Como dichos materiales son magneticamente blandos, su posible uso en los nucleos de los transformadores pueden reducir las perdidas por histeresis en 70%. El presente trabajo evalua tanto las propiedades magneticas como de resistencia a la corrosion de vidrios metalicos magneticamente blandos del tipo en funcion de la cristalinidad de la estructura y el contenido de cobalto. Se encontro que las aleaciones con cobalto exhiben un comportamiento magneticamente mas blando, ya que el campo coercitivo disminuye al aumentar el contenido de cobalto, indicando que las perdidas por histeresis se pueden reducir en un 30%. Sin embargo, muestra un valor mas bajo de magnetizacion remanente y flujo de saturacion con respecto a la muestra Fe75Si15B10, lo cual puede constituir una desventaja en el caso de transporte de grandes flujos magneticos. Se encontro que la sustitucion progresiva de hierro por el cobalto mejora notablemente la resistencia a la corrosion en ambientes de cloruros: En el ensayo EIS, la aleacion Co75Si15B10 mostro una impedancia a baja frecuencia cinco ordenes de magnitud mayor que la muestra Fe75Si15B10. Los resultados de perdida de peso corroboran este resultado. Por otro lado, Las muestras amorfas exhiben un mejor comportamiento en cuanto resistencia a la corrosion que las homologas cristalinas y semicristalinas, comprobandose la hipotesis que la presencia de nanoprecipitados genera regiones electroquimicamente mas activas en las interfaces matriz-precipitado.
Recubrimientos de Hidroxiapatita sintética producida por precipitación y calcinación a 850 °C fueron depositados sobre sustratos de Ti6Al4V mediante proyección térmica por combustión. Las fases presentes en el material sintetizado y en los recubrimientos elaborados fueron determinadas mediante Difracción de Rayos X. Los recubrimientos fueron evaluados en condiciones in vitro con fluido fisiológico a 37 °C que simula el plasma humano, por periodos de 3, 7, 15 y 30 días. La superficie de los recubrimientos fue caracterizada antes y después de los ensayos in vitro mediante Microscopía Electrónica de Barrido y por Barrido de Energía Dispersiva. La concentración de iones de fosfato y de calcio en el fluido fisiológico fue determinada mediante espectrofotometría. Los resultados de las pruebas in vitro sugieren la acción de dos mecanismos: disolución del recubrimiento en el fluido fisiológico y posterior precipitación de cristales de calcio y fósforo sobre la superficie de la capa de Hidroxiapatita.
Coatings were elaborated onto Ti6Al4V substrates using the oxyacetylene flame spraying process from hydroxyapatite synthesized by precipitation and calcination to 850 degrees C. The phases in the hydroxyapatite powders and coatings were determined by X Ray Diffraction. The,surface of coating was exposed to in vitro condition using a Simulated Biological Fluid (SBF), which was heated to 37 degrees C. The in vitro tests were realized during 3, 7, 15 and 30 days. The surface of coatings was evaluated before and after the in vitro tests, by Scanning Electron Microscopy and chemical microanalysis was realized by Energy Dispersive X-Ray Spectroscopy, while the phosphate and calcium ions in the SBF were determined by spectrophotometry. The in vitro tests results indicate that phosphate and calcium ions were dissolved from the surface of coating to fluid and then, calcium phosphate crystals were precipitate on the coatings.
Summary The effects of two types of hydroxylapatite on bone synthesis and properties were evaluated. An osteoconductive resorbable hydroxyapatite (OseoU), synthesized at two different temperatures of calcination (Type A and Type B) was compared with a commercial mixture of hydroxyapatite (Osteogen®), commonly used in several surgical procedures involving bone loss. The synthesis was performed in the laboratories of the University of Antioquia by precipitating a mixture of calcium nitrate and ammonium phosphate. The products obtained and the commercial hydroxyapatite were characterized by scanning electron microscopy (SEM), X- ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), and energy dispersive spectroscopy (EDS). Osteoconductive and osseointegration characteristics were measured according to the products ability to induce local cell differentiation into bone forming cells. These characteristics were evaluated in hydroxyapatite implants performed in 70 New Zealand breed rabbits distributed into seven groups of 10 animals each, tested at 7, 14, 21, 28, 42, 60 and 90 days after the surgical procedure. seven groups of 10 animals each, tested at 7, 14, 21, 28, 42, 60 and 90 days after the surgical procedure. The results showed that Osteogen® and OseoU have similar characteristics in terms of crystal structure, chemical composition and adsorption properties, but morphological differences regarding particle shape. The analysis of variance found no statistically significant differences for the histopathological variables evaluated in both hydroxyapatite groups (p > 0.05), indicating that the hydroxyapatites synthesized at the University of Antioquia (OseoU) had the same results as the commercial hydroxyapatite. Key words: bone regeneration, hydroxyapatite, osteoconduction, osseointegration, synthetic bone substitutes. Resumen En el presente artículo se evalúan las propiedades de osteoconducción y osteointegración de una hidroxiapatita reabsorbible (OseoU), procesada a dos temperaturas diferentes de calcinación (Tipo A y Tipo B), con el propósito de compararlas con un preparado comercial de hidroxiapatita (Osteogen®), utilizado para múltiples procedimientos quirúrgicos en los cuales se involucra la pérdida de tejido óseo. La síntesis se realizó en los laboratorios de la Universidad de Antioquia por el método de precipitación acuosa de la mezcla de nitrato de calcio y de fosfato de amonio. Los productos obtenidos y la hidroxiapatita comercial fueron caracterizados por microscopia electrónica de barrido (SEM), difracción de rayos X (DRX), espectroscopia de infrarrojo transformada de Fourier (FTIR) y espectrometría por energía dispersiva (EDS). Las características de osteoconducción y osteointegración fueron medidas de acuerdo a la capacidad de los productos para inducir la diferenciación de células locales a células formadoras de hueso. Dichas características, se evaluaron en implantes de hidroxiapatita realizados en 70 conejos de la raza Nueva Zelanda distribuidos en siete grupos de 10 animales cada uno, evaluados a los 7, 14, 21, 28, 42, 60 y 90 días de efectuado el procedimiento quirúrgico. Los resultados obtenidos demostraron que el OseoU y el Osteogen®, presentaron características similares en cuanto a la estructura cristalina, la composición química y la adsorción, con apreciables diferencias morfológicas con respecto a la forma de las partículas. Al realizar el análisis de varianza no se encontraron diferencias estadísticas significativas para las variables histopatológicas evaluadas en las dos hidroxiapatitas (p>0.05), indicando que las hidroxiapatitas sintetizadas en la Universidad de Antioquia (OseoU) tuvieron el mismo resultado que la hidroxiapatita comercial (Osteogen®) en la osteoconducción y la osteointegración del tejido óseo. Palabras clave: hidroxiapatita, osteoconducción, osteointegración, regeneración ósea, sustitutos sintéticos de hueso. Resumo No presente estudo foram avaliadas as propriedades de ostecondução e osteointegração de uma hidroxiapatita reabsorvivel (OseoU), processada a duas temperaturas de calcinaçao (Tipo A e B), com o propósito de serem comparadas com um produto comercial (Osteogen®), utilizado para múltiples procedimentos cirúrgicos nos quais se envolve a perda do tecido osso. Asíntese foi realizada nos laboratorios da Universidad de Antioquia pelo método de precipitação aquosa da mistura de nitrato de cálcio e fosfato de amônio. Os produtos obtidos e a hidroxiapatita comercial foram caracterizados por microscopia eletrônica de barrido (SEM), difração raios X (DRX), espectroscopia de infravermelho transformada de Fourier (FTIR) e espectrometria por energia dispersiva (EDS). As características de osteocondução e osteointegração foram mensuradas de acordo à capacidade dos produtos para induzir a diferenciação das células locais formadoras do osso. Estas características foram avaliadas em implantações de hidroxiapatita realizadas em 70 coelhos da raça Nova Zelândia distribuídos em sete grupos de 10 animais cada um, avaliados aos 7, 14, 21, 28, 42, 60 e 90 dias de efetuado o procedimento cirúrgico. Os resultados obtidos demonstraram que o OseoU e o Osteogen® apresentaram características similares em quanto à estrutura cristalina, a comparação química e à absorção, com apreciáveis diferenças morfológicas com respeito à forma das partículas. Ao realizar as análises de variâncias não foram encontradas diferencias estatísticas significativas para as variáveis histopatológicas avaliadas nas duas hidroxiapatitas (p>0.05), indicando que as hidroxiapatitas sintetizadas na Universidad de Antioquia (OseoU) tiveram o mesmo resultado que a hidroxiapatita comercial (Osteogen®) em osteocondução e osteointegração do tecido ósseo. Palavras chave: hidroxiapatita, regeneração óssea, substitutos sintéticos para osso.
The effects of two types of hydroxylapatite on bone synthesis and properties were evaluated. An osteoconductive resorbable hydroxyapatite (OseoU), synthesized at two different temperatures of calcination (Type A and Type B) was compared with a commercial mixture of hydroxyapatite (Osteogen®), commonly used in several surgical procedures involving bone loss. The synthesis was performed in the laboratories of the University of Antioquia by precipitating a mixture of calcium nitrate and ammonium phosphate. The products obtained and the commercial hydroxyapatite were characterized by scanning electron microscopy (SEM), X- ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), and energy dispersive spectroscopy (EDS). Osteoconductive and osseointegration characteristics were measured according to the products ability to induce local cell differentiation into bone forming cells. These characteristics were evaluated in hydroxyapatite implants performed in 70 New Zealand breed rabbits distributed into seven groups of 10 animals each, tested at 7, 14, 21, 28, 42, 60 and 90 days after the surgical procedure.En el presente artículo se evalúan las propiedades de osteoconducción y osteointegración de una hidroxiapatita reabsorbible (OseoU), procesada a dos temperaturas diferentes de calcinación (Tipo A y Tipo B), con el propósito de compararlas con un preparado comercial de hidroxiapatita (Osteogen®), utilizado para múltiples procedimientos quirúrgicos en los cuales se involucra la pérdida de tejido óseo. La síntesis se realizó en los laboratorios de la Universidad de Antioquia por el método de precipitación acuosa de la mezcla de nitrato de calcio y de fosfato de amonio. Los productos obtenidos y la hidroxiapatita comercial fueron caracterizados por microscopia electrónica de barrido (SEM), difracción de rayos X (DRX), espectroscopia de infrarrojo transformada de Fourier (FTIR) y espectrometría por energía dispersiva (EDS). Las características de osteoconducción y osteointegración fueron medidas de acuerdo a la capacidad de los productos para inducir la diferenciación de células locales a células formadoras de hueso. Dichas características, se evaluaron en implantes de hidroxiapatita realizados en 70 conejos de la raza Nueva Zelanda distribuidos en siete grupos de 10 animales cada uno, evaluados a los 7, 14, 21, 28, 42, 60 y 90 días de efectuado el procedimiento quirúrgico. Los resultados obtenidos demostraron que el OseoU y el Osteogen®, presentaron características similares en cuanto a la estructura cristalina, la composición química y la adsorción, con apreciables diferencias morfológicas con respecto a la forma de las partículas. Al realizar el análisis de varianza no se encontraron diferencias estadísticas significativas para las variables histopatológicas evaluadas en las dos hidroxiapatitas (p>0.05), indicando que las hidroxiapatitas sintetizadas en la Universidad de Antioquia (OseoU) tuvieron el mismo resultado que la hidroxiapatita comercial (Osteogen®) en la osteoconducción y la osteointegración del tejido óseo.No presente estudo foram avaliadas as propriedades de ostecondução e osteointegração de uma hidroxiapatita reabsorvivel (OseoU), processada a duas temperaturas de calcinaçao (Tipo A e B), com o propósito de serem comparadas com um produto comercial (Osteogen®), utilizado para múltiples procedimentos cirúrgicos nos quais se envolve a perda do tecido osso. Asíntese foi realizada nos laboratorios da Universidad de Antioquia pelo método de precipitação aquosa da mistura de nitrato de cálcio e fosfato de amônio. Os produtos obtidos e a hidroxiapatita comercial foram caracterizados por microscopia eletrônica de barrido (SEM), difração raios X (DRX), espectroscopia de infravermelho transformada de Fourier (FTIR) e espectrometria por energia dispersiva (EDS). As características de osteocondução e osteointegração foram mensuradas de acordo à capacidade dos produtos para induzir a diferenciação das células locais formadoras do osso. Estas características foram avaliadas em implantações de hidroxiapatita realizadas em 70 coelhos da raça Nova Zelândia distribuídos em sete grupos de 10 animais cada um, avaliados aos 7, 14, 21, 28, 42, 60 e 90 dias de efetuado o procedimento cirúrgico. Os resultados obtidos demonstraram que o OseoU e o Osteogen® apresentaram características similares em quanto à estrutura cristalina, a comparação química e à absorção, com apreciáveis diferenças morfológicas com respeito à forma das partículas. Ao realizar as análises de variâncias não foram encontradas diferencias estatísticas significativas para as variáveis histopatológicas avaliadas nas duas hidroxiapatitas (p>0.05), indicando que as hidroxiapatitas sintetizadas na Universidad de Antioquia (OseoU) tiveram o mesmo resultado que a hidroxiapatita comercial (Osteogen®) em osteocondução e osteointegração do tecido ósseo.
En el presente artículo se evalúan las propiedades de osteoconducción y osteointegración de una hidroxiapatita reabsorbible (OseoU), procesada a dos temperaturas diferentes de calcinación (Tipo A y Tipo B), con el propósito de compararlas con un preparado comercial de hidroxiapatita (Osteogen®), utilizado para múltiples procedimientos quirúrgicos en los cuales se involucra la pérdida de tejido óseo. La síntesis se realizó en los laboratorios de la Universidad de Antioquia por el método de precipitación acuosa de la mezcla de nitrato de calcio y de fosfato de amonio. Los productos obtenidos y la hidroxiapatita comercial fueron caracterizados por microscopia electrónica de barrido (SEM), difracción de rayos X (DRX), espectroscopia de infrarrojo transformada de Fourier (FTIR) y espectrometría por energía dispersiva (EDS). Las características de osteoconducción y osteointegración fueron medidas de acuerdo a la capacidad de los productos para inducir la diferenciación de células locales a células formadoras de hueso. Dichas características, se evaluaron en implantes de hidroxiapatita realizados en 70 conejos de la raza Nueva Zelanda distribuidos en siete grupos de 10 animales cada uno, evaluados a los 7, 14, 21, 28, 42, 60 y 90 días de efectuado el procedimiento quirúrgico. Los resultados obtenidos demostraron que el OseoU y el Osteogen®, presentaron características similares en cuanto a la estructura cristalina, la composición química y la adsorción, con apreciables diferencias morfológicas con respecto a la forma de las partículas. Al realizar el análisis de varianza no se encontraron diferencias estadísticas significativas para las variables histopatológicas evaluadas en las dos hidroxiapatitas (p>0.05), indicando que las hidroxiapatitas sintetizadas en la Universidad de Antioquia (OseoU) tuvieron el mismo resultado que la hidroxiapatita comercial (Osteogen®) en la osteoconducción y la osteointegración del tejido óseo.
The interaction mechanism between copper and propionic acid vapors is shown. Exposures were carried out to various pollutant concentrations and times. Cathodic scan, x-ray diffraction (XRD) and scanning electrode microscope (SEM) were used to quantify the degree of deterioration. The results obtained were explained by the following mechanism: A cuprite (Cu2O) layer covers the copper surface immediately; this compound in presence of adsorbed water is oxidized to tenorite (CuO). The hydration of the tenorite layer benefits the formation of a hydroxide compound such as CuO•xH2O. As the pollutant level is increased, insoluble basic propionate is formed (Cu(OH)x(CH3CH2 COO)2-x). Higher concentrations of propionic acid acidify the monolayers and a new compound Cu(CH3CH2COO)2•H 2O begins to precipitate at low pH, this is the main constituent of the green olive patina formed under these conditions. This mechanism agrees, in general terms, with those proposed in previous works to study the interaction between copper and the acetic and formic acids.
En una camara Cebelcor, se realizaron ensayos ciclicos de inmersion y emersion de dos aceros comerciales (ASTM A36 y ASTM A242) y tres experimentales (0,50% Ni, 0,50% Cu y 0,25% Cu+0,25%Ni, fundidos en horno de plasma) en solucion aireada Na2SO4 10-3M. Se emplearon cuatro replicas de cada acero evaluado. En ellas se realizaron medidas de espectroscopia de impedancia electroquimica (EIS) in-situ, en el rango de bajas frecuencias (200 Hz-0,01Hz) para 1, 15, 30, 45, 60, y 90 dias. Al final de la exposicion, las probetas se caracterizaron por fuera de la camara Cebelcor (EIS ex situ) utilizando un rango mas amplio de frecuencias (900 kHz-0,01 Hz). La simulacion de estos ultimos datos mediante un circuito equivalente con impedancia de difusion de Warburg, permitio dilucidar la presencia de dos capas de herrumbre de diferentes constantes dielectricas, una interna y otra mas externa, esta ultima asociada a un aumento del area superficial efectiva y a la hidratacion en contacto con el electrolito. Los resultadosindicaron que, tanto para las medidas in situ y ex situ en las probetas con 90 dias de exposicion, existe una diferencia significativa entre el acero al carbono (ASTM A36) y los otros materiales evaluados, evidenciando una mayor resistencia ohmica de la herrumbre de estos ultimos. La herrumbre del acero ASTM A36, esta compuesta por una mezcla de α/γ FeOOH mas magnetita (10%), a diferencia de los otros aceros evaluados, que mostraron solo α/γ FeOOH. Los aceros experimentales mostraron caracteristicas similares alacero autoprotector ASTM A242. Se concluyo un efecto similar entre el cobre y el niquel en la cinetica a la corrosion atmosferica de los aceros. Por ultimo se realiza una interpretacion de los parametros encontrados con la simulacion utilizada, proponiendo un modelo fenomenologico que explica los resultados encontrados.