Pharmacokinetics and biodistribution of 100 nmol/kg TLR2L-800 in an SU.86.86 orthotopic human pancreatic cancer xenograft mouse model.
Introduction Measurement of repeatability and reproducibility (R&R) is necessary to realize the full potential of positron emission tomography (PET). Several studies have evaluated the reproducibility of PET using 18F-FDG, the most common PET tracer used in oncology, but similar studies using other PET tracers are scarce. Even fewer assess agreement and R&R with statistical methods designed explicitly for the task. 18F-(2S, 4R)-4-fluoro-glutamine (18F-Gln) is a PET tracer designed for imaging glutamine uptake and metabolism. This study illustrates high reproducibility and repeatability with 18F-Gln for in vivo research. Methods Twenty mice bearing colorectal cancer cell line xenografts were injected with ~9 MBq of 18F-Gln and imaged in an Inveon microPET. Three individuals analyzed the tumor uptake of 18F-Gln using the same set of images, the same image analysis software, and the same analysis method. Scans were randomly re-ordered for a second repeatability measurement 6 months later. Statistical analyses were performed using the methods of Bland and Altman (B&A), Gauge Reproducibility and Repeatability (Gauge R&R), and Lin’s Concordance Correlation Coefficient. A comprehensive equivalency test, designed to reject a null hypothesis of non-equivalence, was also conducted. Results In a two-way random effects Gauge R&R model, variance among mice and their measurement variance were 0.5717 and 0.024. Reproducibility and repeatability accounted for 31% and 69% of the total measurement error, respectively. B&A repeatability coefficients for analysts 1, 2, and 3 were 0.16, 0.35, and 0.49. One-half B&A agreement limits between analysts 1 and 2, 1 and 3, and 2 and 3 were 0.27, 0.47, and 0.47, respectively. The mean square deviation and total deviation index were lowest for analysts 1 and 2, while coverage probabilities and coefficients of the individual agreement were highest. Finally, the definitive agreement inference hypothesis test for equivalency demonstrated that all three confidence intervals for the average difference of means from repeated measures lie within our a priori limits of equivalence (i.e. ± 0.5%ID/g). Conclusions Our data indicate high individual analyst and laboratory-level reproducibility and repeatability. The assessment of R&R using the appropriate methods is critical and should be adopted by the broader imaging community.
Identification of pancreatic tumors and suspected cause of death for individual mice.
In vivo fluorescence molecular tomographic images of TLR2L-800 labeled SU.86.86 orthotopic pancreatic tumors in nude mice 24 h post-surgery.
To increase the achievement of negative R0 surgical margins and increase the low survival rates of pancreatic cancer, improvements in assessing tumor margins during surgical resections are needed. This can be accomplished by using pancreatic cancer-targeted fluorescence molecular imaging agents to intraoperatively detect tumor margins in real time. Because Toll-like receptor 2 (TLR2) is broadly expressed among many cancer types including pancreatic adenocarcinomas, a high-affinity TLR2-targeted fluorescence molecular imaging agent (TLR2L-800) was developed. We investigate the potential for increased survival by employing real-time intraoperative tumor detection in a preclinical orthotopic human pancreatic xenograft tumor model using TLR2L-800. Three cohorts of nude mice bearing orthotopic human pancreatic xenograft tumors were intravenously injected with TLR2L-800. At 24 hours postinjection, one cohort underwent in vivo fluorescence-guided surgical removal of tumors using a real-time fluorescence imaging platform, a second cohort underwent visible light surgery (VLS), and a third cohort did not undergo surgery. A fourth, nontumor-bearing cohort was administered TLR2L-800 with no surgery. At 41 days postsurgery, the survival rates were 53% for the fluorescence-guided surgery (FGS) group and 0% for both the VLS and the tumor-bearing no-surgery group. The overall 200-day survival rate of 35% for the FGS group was significant compared with 0% for the VLS group (P value = 0.0018). This study demonstrates the potential of increasing disease-free survival for patients with pancreatic cancer by increasing the attainment of R0 margins using a novel tumor-targeted lipopeptide ligand-based fluorescence molecular imaging agent, TLR2L-800, during real-time FGS.Significance: Human TLR2 is broadly expressed among pancreatic adenocarcinomas, and the highly specific TLR2L-800 fluorescence molecular imaging agent has potential for use in fluorescence-guided surgery to increase R0 margins and improve patient survival.
Nonlinear regression analyses of clearance of 100 nmol/kg TLR2-800 in TLR2-negative tissues and TLR2-positive tumors