OBJECTIVE:To determine the contrast-enhanced mammography-guided biopsy (CEM-Bx) success rate for MRI-suspicious lesions lacking known tomosynthetic or sonographic correlate along with factors associated with biopsy success. METHODS:From June 2022 to August 2023, this prospective IRB-approved study enrolled women with breast MRI lesions rated BI-RADS ≥4A for CEM-Bx. Ipsilateral contrast-enhanced mammography (CEM) was performed in the biopsy suite and correlated with MRI. For visible lesions, CEM-Bx was performed immediately after prebiopsy CEM. Success criteria included enhancing correlate visualization and biopsy completion with accurate lesion sampling. An MRI-guided biopsy was recommended for failures. The success rate was evaluated with the Wilson score interval. MRI lesion and patient characteristics (size, type [mass, focus, or nonmass enhancement], kinetics, breast density, body mass index, background parenchymal enhancement [BPE], radiologist CEM experience, radiologist MRI experience, and histopathology) were collected. Multivariable logistic regression was performed with backward feature selection. RESULTS:Analysis included 152 women (mean age 53 ± 11 years) with 184 lesions. CEM-Bx was successful for 106/184 (57.6%; [95% CI, 50.0-65.0]) lesions with 24/106 (22.6%) malignant. Of 78 failures, 60 (76.9%) lacked enhancement on prebiopsy CEM, 14 (17.9%) were not visualized with the biopsy grid, and 4 (5.1%) were not accurately sampled; 14/78 (17.9%) failures proved malignant. Increasing lesion size (odds ratio [OR] = 1.03; [95% CI, 1.01-1.06]), more years of radiologist CEM experience (OR = 1.24; [95% CI, 1.01-1.49]), and lower BPE (OR = 0.68 [95% CI, 0.46-0.98]) were associated with success. CONCLUSION:Contrast-enhanced mammography biopsy can be a successful alternative to MRI-guided biopsy for MRI-detected lesions. MRI-guided biopsy should be pursued if CEM-Bx fails.
OBJECTIVE:To assess the performance and cost implications of contrast-enhanced mammography-guided biopsy (CEM Bx). METHODS:This is a prospective study from May 5, 2021, to April 18, 2022, across 2 U.S. academic centers, evaluating technical success, patient/radiologist feedback, and operational factors of CEM Bx. Inclusion criteria included that patients be 40 years or older and recommended for biopsy with suspicious findings on contrast-enhanced mammography (CEM). Descriptive statistics are reported for clinical outcomes, length of procedure, and user and participant feedback. An estimate of cost was made by comparing general Medicare costs that are being billed for CEM Bx and post-clip mammogram ($475.48) to the Medicare costs of MRI-guided biopsy (MRI Bx) and post-clip placement mammogram ($845.94). RESULTS:Eighty-two participants enrolled. Twenty-two were excluded at the time of CEM Bx (22/82, 27%). Sixty participants were included (mean age 57 years, range 33 to 81 years) with 63 suspicious CEM lesions. The malignancy rate was 22% (14/63). A technical success rate of 100% was achieved. Average CEM Bx time was 29% to 33% the average reported MRI-guided breast biopsy times (CEM Bx = 11 minutes; MRI Bx = 33 to 38 minutes), indicating operational efficiencies. A positive opinion of CEM Bx was reported by 78% of radiologists, 93% of technologists, and 98% of patients. The estimated cost for each CEM Bx was ~ 45% lower than MRI Bx. CONCLUSION:CEM Bx demonstrates high success rates and satisfaction scores. CEM Bx resulted in shorter procedure times, enhanced operational efficiency, and ~45% reduction in costs compared with MRI Bx. As advancements continue, we anticipate CEM Bx will offer a cost-efficient and timely option for breast biopsy.
Among women eligible for supplemental MRI screening according to state insurance law, adding contrast-enhanced mammography to digital breast tomosynthesis significantly increased early breast cancer detection alongside a 13% increase in the false-positive rate.
Background Digital breast tomosynthesis (DBT) is often inadequate for screening women with a personal history of breast cancer (PHBC). The ongoing prospective Tomosynthesis or Contrast-Enhanced Mammography, or TOCEM, trial includes three annual screenings with both DBT and contrast-enhanced mammography (CEM). Purpose To perform interim assessment of cancer yield, stage, and recall rate when CEM is added to DBT in women with PHBC. Materials and Methods From October 2019 to December 2022, two radiologists interpreted both examinations: Observer 1 reviewed DBT first and then CEM, and observer 2 reviewed CEM first and then DBT. Effects of adding CEM to DBT on incremental cancer detection rate (ICDR), cancer type and node status, recall rate, and other performance characteristics of the primary radiologist decisions were assessed. Results Among the participants (mean age at entry, 63.6 years ± 9.6 [SD]), 1273, 819, and 227 women with PHBC completed year 1, 2, and 3 screening, respectively. For observer 1, year 1 cancer yield was 20 of 1273 (15.7 per 1000 screenings) for DBT and 29 of 1273 (22.8 per 1000 screenings; ICDR, 7.1 per 1000 screenings [95% CI: 3.2, 13.4]) for DBT plus CEM (P < .001). Year 2 plus 3 cancer yield was four of 1046 (3.8 per 1000 screenings) for DBT and eight of 1046 (7.6 per 1000 screenings; ICDR, 3.8 per 1000 screenings [95% CI: 1.0, 7.6]) for DBT plus CEM (P = .001). Year 1 recall rate for observer 1 was 103 of 1273 (8.1%) for (incidence) DBT alone and 187 of 1273 (14.7%) for DBT plus CEM (difference = 84 of 1273, 6.6% [95% CI: 5.3, 8.1]; P < .001). Year 2 plus 3 recall rate was 40 of 1046 (3.8%) for DBT and 92 of 1046 (8.8%) for DBT plus CEM (difference = 52 of 1046, 5.0% [95% CI: 3.7, 6.3]; P < .001). In 18 breasts with cancer detected only at CEM after integration of both observers, 13 (72%) cancers were invasive (median tumor size, 0.6 cm) and eight of nine (88%) with staging were N0. Among 1883 screenings with adequate reference standard, there were three interval cancers (one at the scar, two in axillae). Conclusion CEM added to DBT increased early breast cancer detection each year in women with PHBC, with an accompanying approximately 5.0%-6.6% recall rate increase. Clinical trial registration no. NCT04085510 © RSNA, 2024 Supplemental material is available for this article.
PURPOSE To assess diagnostic performance of digital breast tomosynthesis (DBT) alone or combined with technologist-performed handheld screening ultrasound (US) in women with dense breasts. METHODS In an institutional review board–approved, Health Insurance Portability and Accountability Act–compliant multicenter protocol in western Pennsylvania, 6,179 women consented to three rounds of annual screening, interpreted by two radiologist observers, and had appropriate follow-up. Primary analysis was based on first observer results. RESULTS Mean participant age was 54.8 years (range, 40-75 years). Across 17,552 screens, there were 126 cancer events in 125 women (7.2/1,000; 95% CI, 5.9 to 8.4). In year 1, DBT-alone cancer yield was 5.0/1,000, and of DBT+US, 6.3/1,000, difference 1.3/1,000 (95% CI, 0.3 to 2.1; P = .005). In years 2 + 3, DBT cancer yield was 4.9/1,000, and of DBT+US, 5.9/1,000, difference 1.0/1,000 (95% CI, 0.4 to 1.5; P < .001). False-positive rate increased from 7.0% for DBT in year 1 to 11.5% for DBT+US and from 5.9% for DBT in year 2 + 3 to 9.7% for DBT+US ( P < .001 for both). Nine cancers were seen only by double reading DBT and one by double reading US. Ten interval cancers (0.6/1,000 [95% CI, 0.2 to 0.9]) were identified. Despite reduction in specificity, addition of US improved receiver operating characteristic curves, with area under receiver operating characteristic curve increasing from 0.83 for DBT alone to 0.92 for DBT+US in year 1 ( P = .01), with smaller improvements in subsequent years. Of 6,179 women, across all 3 years, 172/6,179 (2.8%) unique women had a false-positive biopsy because of DBT as did another 230/6,179 (3.7%) women because of US ( P < .001). CONCLUSION Overall added cancer detection rate of US screening after DBT was modest at 19/17,552 (1.1/1,000; CI, 0.5- to 1.6) screens but potentially overcomes substantial increases in false-positive recalls and benign biopsies.
Objective Evaluate lesion visibility and radiologist confidence during contrast-enhanced mammography (CEM)-guided biopsy. Methods Women with BI-RADS >= 4A enhancing breast lesions were prospectively recruited for 9-g vacuum-assisted CEM-guided biopsy. Breast density, background parenchymal enhancement (BPE), lesion characteristics (enhancement and conspicuity), radiologist confidence (scale 1-5), and acquisition times were collected. Signal intensities in specimens were analyzed. Patient surveys were collected. Results A cohort of 28 women aged 40-81 years (average 57) had 28 enhancing lesions (7/28, 25% malignant). Breast tissue was scattered (10/28, 36%) or heterogeneously dense (18/28, 64%) with minimal (12/28, 43%), mild (7/28, 25%), or moderate (9/28, 32%) BPE on CEM. Twelve non-mass enhancements, 11 masses, 3 architectural distortions, and 2 calcification groups demonstrated weak (12/28, 43%), moderate (14/28, 50%), or strong (2/28, 7%) enhancement. Specimen radiography demonstrated lesion enhancement in 27/28 (96%). Radiologists reported complete lesion removal on specimen radiography in 8/28 (29%). Average time from contrast injection to specimen radiography was 18 minutes (SD = 5) and, to post-procedure mammogram (PPM), 34 minutes (SD = 10). Contrast-enhanced mammography PPM was performed in 27/28 cases; 13/19 (68%) of incompletely removed lesions on specimen radiography showed residual enhancement; 6/19 (32%) did not. Across all time points, average confidence was 2.2 (SD = 1.2). Signal intensities of enhancing lesions were similar to iodine. Patients had an overall positive assessment. Conclusion Lesion enhancement persisted through PPM and was visible on low energy specimen radiography, with an average "confident" score. Contrast-enhanced mammography-guided breast biopsy is easily implemented clinically. Its availability will encourage adoption of CEM.
AimsThe genetic cause of cardiac conduction system disease (CCSD) has not been fully elucidated. Whole-exome sequencing (WES) can detect various genetic variants; however, the identification of pathogenic variants remains a challenge. We aimed to identify pathogenic or likely pathogenic variants in CCSD patients by using WES and 2015 American College of Medical Genetics and Genomics (ACMG) standards and guidelines as well as evaluating the usefulness of functional studies for determining them.Methods and ResultsWe performed WES of 23 probands diagnosed with early-onset (<65 years) CCSD and analyzed 117 genes linked to arrhythmogenic diseases or cardiomyopathies. We focused on rare variants (minor allele frequency < 0.1%) that were absent from population databases. Five probands had protein truncating variants in EMD and LMNA which were classified as “pathogenic” by 2015 ACMG standards and guidelines. To evaluate the functional changes brought about by these variants, we generated a knock-out zebrafish with CRISPR-mediated insertions or deletions of the EMD or LMNA homologs in zebrafish. The mean heart rate and conduction velocities in the CRISPR/Cas9-injected embryos and F2 generation embryos with homozygous deletions were significantly decreased. Twenty-one variants of uncertain significance were identified in 11 probands. Cellular electrophysiological study and in vivo zebrafish cardiac assay showed that 2 variants in KCNH2 and SCN5A, 4 variants in SCN10A, and 1 variant in MYH6 damaged each gene, which resulted in the change of the clinical significance of them from “Uncertain significance” to “Likely pathogenic” in 6 probands.ConclusionsOf 23 CCSD probands, we successfully identified pathogenic or likely pathogenic variants in 11 probands (48%). Functional analyses of a cellular electrophysiological study and in vivo zebrafish cardiac assay might be useful for determining the pathogenicity of rare variants in patients with CCSD. SCN10A may be one of the major genes responsible for CCSD.Translational PerspectiveWhole-exome sequencing (WES) may be helpful in determining the causes of cardiac conduction system disease (CCSD), however, the identification of pathogenic variants remains a challenge. We performed WES of 23 probands diagnosed with early-onset CCSD, and identified 12 pathogenic or likely pathogenic variants in 11 of these probands (48%) according to the 2015 ACMG standards and guidelines. In this context, functional analyses of a cellular electrophysiological study and in vivo zebrafish cardiac assay might be useful for determining the pathogenicity of rare variants, and SCN10A may be one of the major development factors in CCSD.
RATIONALE AND OBJECTIVES:To preliminarily asses if Contrast Enhanced Digital Mammography (CEDM) can accurately reduce biopsy rates for soft tissue BI-RADS 4A or 4B lesions.MATERIALS AND METHODS:Eight radiologists retrospectively and independently reviewed 60 lesions in 54 consenting patients who underwent CEDM under Health Insurance Portability and Accountability Act compliant institutional review board-approved protocols. Readers provided Breast Imaging Reporting & Data System ratings sequentially for digital mammography/digital breast tomosynthesis (DM/DBT), then with ultrasound, then with CEDM for each lesion. Area under the curve (AUC), true positive rates and false positive rates, positive predictive values and negative predictive values were calculated. Statistical analysis accounting for correlation between lesion-examinations and between-reader variability was performed using OR/DBM (for SAS v.3.0), generalized linear mixed model for binary data (proc glimmix, SAS v.9.4, SAS Institute, Cary North Carolina), and bootstrap.RESULTS:The cohort included 49 benign, two high-risk and nine cancerous lesions in 54 women aged 34-74 (average 50) years. Reader-averaged AUC for CEDM was significantly higher than DM/DBT alone (0.85 versus 0.66, p < 0.001) or with US (0.85 versus 0.75, p = 0.001). CEDM increased true positive rates from 0.74 under DB/DBT, and 0.89 with US, to 0.90 with CEDM, (p = 0.019 DM/DBT versus CEDM, p = 0.78 DM/DBT + US versus CEDM) and decreased false positive rates from 0.47 using DM/DBT and 0.61 with US to 0.39 with CEDM (p = 0.017 DM/DBT versus CEDM, p = 0.001 DM/DBT+ US versus CEDM). For an expected cancer rate of 10%, CEDM positive predictive values was 20.5% (95% CI: 16%-27%) and negative predictive values 98.3% (95% CI: 96%-100%).CONCLUSION:Addition of CEDM for evaluation of low-moderate suspicion soft tissue breast lesions can substantially reduce biopsy of benign lesions without compromising cancer detection.
Background Staging newly diagnosed breast cancer by using dynamic contrast material-enhanced MRI is limited by access, high cost, and false-positive findings. The utility of contrast-enhanced mammography (CEM) and 99mTc sestamibi-based molecular breast imaging (MBI) in this setting is largely unknown. Purpose To compare extent-of-disease assessments by using MRI, CEM, and MBI versus pathology in women with breast cancer. Materials and Methods In this HIPAA-compliant prospective study, women with biopsy-proven breast cancer underwent MRI, CEM, and MBI between October 2014 and April 2018. Eight radiologists independently interpreted each examination result prospectively and were blinded to interpretations of findings with the other modalities. Visibility of index malignancies, lesion size, and additional suspicious lesions (malignant or benign) were compared during pathology review. Accuracy of index lesion sizing and detection of additional lesions in women without neoadjuvant chemotherapy were compared. Results A total of 102 women were enrolled and 99 completed the study protocol (mean age, 51 years ± 11 [standard deviation]; range, 32-77 years). Lumpectomy or mastectomy was performed in 71 women (79 index malignancies) without neoadjuvant chemotherapy and in 28 women (31 index malignancies) with neoadjuvant chemotherapy. Of the 110 index malignancies, MRI, CEM, and MBI depicted 102 (93%; 95% confidence interval [CI]: 86%, 97%), 100 (91%; 95% CI: 84%, 96%), and 101 (92%; 95% CI: 85%, 96%) malignancies, respectively. In patients without neoadjuvant chemotherapy, pathologic size of index malignancies was overestimated with all modalities (P = .02). MRI led to overestimation of 24% (17 of 72) of malignancies by more than 1.5 cm compared with 11% (eight of 70) with CEM and 15% (11 of 72) with MBI. MRI depicted more (P = .007) nonindex lesions, with sensitivity similar to that of CEM or MBI, resulting in lower positive predictive value of additional biopsies (13 of 46 [28%; 95% CI: 17%, 44%] for MRI; 14 of 27 [52%; 95% CI: 32%, 71%] for CEM; and 11 of 25 [44%; 95% CI: 24%, 65%] for MBI (overall P = .01). Conclusion Contrast-enhanced mammography, molecular breast imaging, and MRI showed similar detection of all malignancies. MRI depicted more nonindex suspicious benign lesions than did contrast-enhanced mammography or molecular breast imaging, leading to lower positive predictive value of additional biopsies. All three modalities led to overestimation of index tumor size, particularly MRI. © RSNA, 2019 Online supplemental material is available for this article.
Cyanide is a potent toxic agent, and the few available antidotes are not amenable to rapid deployment in mass exposures. As a result, there are ongoing efforts to exploit different animal models to identify novel countermeasures. We have created a pipeline that combines high-throughput screening in zebrafish with subsequent validation in two mammalian small animal models as well as a porcine large animal model. We found that zebrafish embryos in the first 3 days post fertilization (dpf) are highly resistant to cyanide, becoming progressively more sensitive thereafter. Unbiased analysis of gene expression in response to several hours of ultimately lethal doses of cyanide in both 1 and 7 dpf zebrafish revealed modest changes in iron-related proteins associated with the age-dependent cyanide resistance. Metabolomics measurements demonstrated significant age-dependent differences in energy metabolism during cyanide exposure which prompted us to test modulators of the tricarboxylic acid cycle and related metabolic processes as potential antidotes. In cyanide-sensitive 7 dpf larvae, we identified several such compounds that offer significant protection against cyanide toxicity. Modulators of the pyruvate dehydrogenase complex, as well as the small molecule sodium glyoxylate, consistently protected against cyanide toxicity in 7 dpf zebrafish larvae. Together, our results indicate that the resistance of zebrafish embryos to cyanide toxicity during early development is related to an altered regulation of cellular metabolism, which we propose may be exploited as a potential target for the development of novel antidotes against cyanide poisoning.
Interpretations of breast ultrasound screening examinations result in high recall rates and large inter-radiologist variability, frequently leading to “conservative” recommendations. Double reading of all breast ultrasound screening examinations is cost prohibitive, but double reading of only “initially recalled” cases may prove efficacious. We assessed changes in recommendations, if any, by providing a consensus second opinion in a limited subset of examinations initially recommended for recall. We performed a retrospective reader study with 197 ultrasound examinations (97 not recalled and 100 recalled clinically). First, we generated a consensus “second opinion” consisting of the majority vote of three independent readings of each case by experienced ultrasound interpreters. During the reader study that followed, if the reader recommended a “recall” and the “consensus second opinion” did not, a message to that effect was displayed and the reader was asked to re-review the exam and re-assess if, knowing the second opinion, a re-rating of the case was warranted. We compared performance levels pre- and post- the second opinion. The second opinion resulted in “no recall” recommendations of 141 cases in the entire set, including four cancer cases missed by all three readers. On average, radiologists received “warning” messages in 30 cases (range 15-50), or in ~15% of cases. Rating changes (downgrades to no recall) occurred in 36 of these cases. These changes resulted in a possible recall rate reduction of 28% in prompted cases or 14% overall recall reduction, while increasing the false negative rate by only one case missed by 2 readers (~1%).
Cyanide is a potent toxic agent, and the few available antidotes are not amenable to rapid deployment in mass exposures. As a result, there are ongoing efforts to exploit different animal models to identify novel countermeasures. We have created a pipeline that combines high-throughput screening in zebrafish with subsequent validation in two mammalian small animal models as well as a porcine large animal model. We found that zebrafish embryos in the first 3 days post fertilization (dpf) are highly resistant to cyanide, becoming progressively more sensitive thereafter. Unbiased analysis of gene expression in response to several hours of ultimately lethal doses of cyanide in both 1 and 7 dpf zebrafish revealed modest changes in iron-related proteins associated with the age-dependent cyanide resistance. Metabolomics measurements demonstrated significant age-dependent differences in energy metabolism during cyanide exposure which prompted us to test modulators of the tricarboxylic acid cycle and related metabolic processes as potential antidotes. In cyanide-sensitive 7 dpf larvae, we identified several such compounds that offer significant protection against cyanide toxicity. Modulators of the pyruvate dehydrogenase complex, as well as the small molecule sodium glyoxylate, consistently protected against cyanide toxicity in 7 dpf zebrafish larvae. Together, our results indicate that the resistance of zebrafish embryos to cyanide toxicity during early development is related to an altered regulation of cellular metabolism, which we propose may be exploited as a potential target for the development of novel antidotes against cyanide poisoning.
Performance changes in a binary environment when using additional information is affected only when changes in recommendations are made due to the additional information in question. In a recent study, we have shown that, contrary to general expectation, introducing prior examinations improved recall rates, but not sensitivity. In this study, we assessed cancer detection differences when prior examinations and/or digital breast tomosynthesis (DBT) were made available to the radiologist. We identified a subset of 21 cancer cases with differences in the number of radiologists who recalled these cases after reviewing either a prior examination or DBT. For the cases with differences in recommendations after viewing either priors or DBT, separately, we evaluated the total number of readers that changed their recommendations, regardless of the specific radiologist in question. Confidence intervals for the number of readers and a test for the hypothesis of no difference was performed using the non-parameteric bootstrap approach addressing both case and reader-related sources of variability by resampling cases and readers. With the addition of priors, there were 14 cancer cases (out of 15) where the number of "recalling radiologists" decreased. With the addition of DBT, the number of "recalling radiologists" decreased in only five cases (out of 15) while increasing in the remaining 9 cases. Unlike most new approaches to breast imaging DBT seems to improve both recall rates and cancer detection rates. Changes in recommendations were noted by all radiologists for all cancers by type, size, and breast density.
PURPOSE To assess the effect of and interaction between the availability of prior images and digital breast tomosynthesis (DBT) images in decisions to recall women during mammogram interpretation. MATERIALS AND METHODS Verbal informed consent was obtained for this HIPAA-compliant institutional review board-approved protocol. Eight radiologists independently interpreted twice deidentified mammograms obtained in 153 women (age range, 37-83 years; mean age, 53.7 years ± 9.3 [standard deviation]) in a mode by reader by case-balanced fully crossed study. Each study consisted of current and prior full-field digital mammography (FFDM) images and DBT images that were acquired in our facility between June 2009 and January 2013. For one reading, sequential ratings were provided by using (a) current FFDM images only, (b) current FFDM and DBT images, and (c) current FFDM, DBT, and prior FFDM images. The other reading consisted of (a) current FFDM images only, (b) current and prior FFDM images, and (c) current FFDM, prior FFDM, and DBT images. Fifty verified cancer cases, 60 negative and benign cases (clinically not recalled), and 43 benign cases (clinically recalled) were included. Recall recommendations and interaction between the effect of prior FFDM and DBT images were assessed by using a generalized linear model accounting for case and reader variability. RESULTS Average recall rates in noncancer cases were significantly reduced with the addition of prior FFDM images by 34% (145 of 421) and 32% (106 of 333) without and with DBT images, respectively (P < .001). However, this recall reduction was achieved at the cost of a corresponding 7% (23 of 345) and 4% (14 of 353) reduction in sensitivity (P = .006). In contrast, availability of DBT images resulted in a smaller reduction in recall rates (false-positive interpretations) of 19% (76 of 409) and 26% (71 of 276) without and with prior FFDM images, respectively (P = .001). Availability of DBT images resulted in 4% (15 of 338) and 8% (25 of 322) increases in sensitivity, respectively (P = .007). The effects of the availability of prior FFDM images or DBT images did not significantly change regardless of the sequence in presentation (P = .81 and P = .47 for specificity and sensitivity, respectively). CONCLUSION The availability of prior FFDM or DBT images is a largely independent contributing factor in reducing recall recommendations during mammographic interpretation.
PURPOSE To assess interpretation performance and radiation dose when two-dimensional synthesized mammography (SM) images versus standard full-field digital mammography (FFDM) images are used alone or in combination with digital breast tomosynthesis images. MATERIALS AND METHODS A fully crossed, mode-balanced multicase (n = 123), multireader (n = 8), retrospective observer performance study was performed by using deidentified images acquired between 2008 and 2011 with institutional review board approved, HIPAA-compliant protocols, during which each patient signed informed consent. The cohort included 36 cases of biopsy-proven cancer, 35 cases of biopsy-proven benign lesions, and 52 normal or benign cases (Breast Imaging Reporting and Data System [BI-RADS] score of 1 or 2) with negative 1-year follow-up results. Accuracy of sequentially reported probability of malignancy ratings and seven-category forced BI-RADS ratings was evaluated by using areas under the receiver operating characteristic curve (AUCs) in the random-reader analysis. RESULTS Probability of malignancy-based mean AUCs for SM and FFDM images alone was 0.894 and 0.889, respectively (difference, -0.005; 95% confidence interval [CI]: -0.062, 0.054; P = .85). Mean AUC for SM with tomosynthesis and FFDM with tomosynthesis was 0.916 and 0.939, respectively (difference, 0.023; 95% CI: -0.011, 0.057; P = .19). In terms of the reader-specific AUCs, five readers performed better with SM alone versus FFDM alone, and all eight readers performed better with combined FFDM and tomosynthesis (absolute differences from 0.003 to 0.052). Similar results were obtained by using a nonparametric analysis of forced BI-RADS ratings. CONCLUSION SM alone or in combination with tomosynthesis is comparable in performance to FFDM alone or in combination with tomosynthesis and may eliminate the need for FFDM as part of a routine clinical study.
Organ development is a highly regulated process involving the coordinated proliferation and differentiation of diverse cellular populations. The pathways regulating cell proliferation and their effects on organ growth are complex and for many organs incompletely understood. In all vertebrate species, the cardiac natriuretic peptides (ANP and BNP) are produced by cardiomyocytes in the developing heart. However, their role during cardiogenesis is not defined. Using the embryonic zebrafish and neonatal mammalian cardiomyocytes we explored the natriuretic peptide signaling network during myocardial development. We observed that the cardiac natriuretic peptides ANP and BNP and the guanylate cyclase-linked natriuretic peptide receptors Npr1 and Npr2 are functionally redundant during early cardiovascular development. In addition, we demonstrate that low levels of the natriuretic peptides preferentially activate Npr3, a receptor with Gi activator sequences, and increase cardiomyocyte proliferation through inhibition of adenylate cyclase. Conversely, high concentrations of natriuretic peptides reduce cardiomyocyte proliferation through activation of the particulate guanylate cyclase-linked natriuretic peptide receptors Npr1 and Npr2, and activation of protein kinase G. These data link the cardiac natriuretic peptides in a complex hierarchy modulating cardiomyocyte numbers during development through opposing effects on cardiomyocyte proliferation mediated through distinct cyclic nucleotide signaling pathways.
Rationale and Objectives. To compare the sensitivities of ultrasound guided core biopsy and fine needle aspiration (FNA) for detection of axillary lymph node metastases in patients with a current diagnosis of ipsilateral breast cancer. Materials and Methods. From December 2008 to December 2010, 105 patients with breast cancer and abnormal appearing lymph nodes in the ipsilateral axilla consented to undergo FNA of an axillary node immediately followed by core biopsy of the same node, both with ultrasound guidance. Experienced pathologists evaluated the aspirate cytology without knowledge of the core histology. Cytology and core biopsy results were compared to sentinel node excision or axillary dissection pathology. Sensitivities were compared using McNemar’s test. Results. Of 70 patients with axillary node metastases, FNA was positive in 55/70 (78.6%) and core was positive in 61/70 (87.1%) (P = 0.18). The FNA and core results were discordant in 14/70 (20%) patients. Ten cases were FNA negative/core positive. Four cases were FNA positive/core negative. Conclusion. Core biopsy detected six (8.6%) more cases of metastatic lymphadenopathy than FNA but the difference in sensitivities was not statistically significant. Core biopsy should be considered if the node is clearly imaged and readily accessible. FNA is a good alternative when a smaller needle is desired due to node location or other patient factors. This trial is registered with NCT01920139.
PURPOSE:To compare the diagnostic performance of breast tomosynthesis versus supplemental mammography views in classification of masses, distortions, and asymmetries.MATERIALS AND METHODS:Eight radiologists who specialized in breast imaging retrospectively reviewed 217 consecutively accrued lesions by using protocols that were HIPAA compliant and institutional review board approved in 182 patients aged 31-60 years (mean, 50 years) who underwent diagnostic mammography and tomosynthesis. The lesions in the cohort included 33% (72 of 217) cancers and 67% (145 of 217) benign lesions. Eighty-four percent (182 of 217) of the lesions were masses, 11% (25 of 217) were asymmetries, and 5% (10 of 217) were distortions that were initially detected at clinical examination in 8% (17 of 217), at mammography in 80% (173 of 217), at ultrasonography (US) in 11% (25 of 217), or at magnetic resonance imaging in 1% (2 of 217). Histopathologic examination established truth in 191 lesions, US revealed a cyst in 12 lesions, and 14 lesions had a normal follow-up. Each lesion was interpreted once with tomosynthesis and once with supplemental mammographic views; both modes included the mediolateral oblique and craniocaudal views in a fully crossed and balanced design by using a five-category Breast Imaging Reporting and Data System (BI-RADS) assessment and a probability-of-malignancy score. Differences between modes were analyzed with a generalized linear mixed model for BI-RADS-based sensitivity and specificity and with modified Obuchowski-Rockette approach for probability-of-malignancy-based area under the receiver operating characteristic (ROC) curve.RESULTS:Average probability-of-malignancy-based area under the ROC curve was 0.87 for tomosynthesis versus 0.83 for supplemental views (P < .001). With tomosynthesis, the false-positive rate decreased from 85% (989 of 1160) to 74% (864 of 1160) (P < .01) for cases that were rated BI-RADS category 3 or higher and from 57% (663 of 1160) to 48% (559 of 1160) for cases rated BI-RADS category 4 or 5 (P < .01), without a meaningful change in sensitivity. With tomosynthesis, more cancers were classified as BI-RADS category 5 (39% [226 of 576] vs 33% [188 of 576]; P = .017) without a decrease in specificity.CONCLUSION:Tomosynthesis significantly improved diagnostic accuracy for noncalcified lesions compared with supplemental mammographic views.
AIMS:Despite increased understanding of the fundamental biology regulating cardiomyocyte hypertrophy and heart failure, it has been challenging to find novel chemical or genetic modifiers of these pathways. Traditional cell-based methods do not model the complexity of an intact cardiovascular system and mammalian models are not readily adaptable to chemical or genetic screens. Our objective was to create an in vivo model suitable for chemical and genetic screens for hypertrophy and heart failure modifiers.METHODS AND RESULTS:Using the developing zebrafish, we established that the cardiac natriuretic peptide genes (nppa and nppb), known markers of cardiomyocyte hypertrophy and heart failure, were induced in the embryonic heart by pathological cardiac stimuli. This pathological induction was distinct from the developmental regulation of these genes. We created a luciferase-based transgenic reporter line that accurately modelled the pathological induction patterns of the zebrafish nppb gene. Utilizing this reporter line, we were able to show remarkable conservation of pharmacological responses between the larval zebrafish heart and adult mammalian models.CONCLUSION:By performing a focused screen of chemical agents, we were able to show a distinct response of a genetic model of hypertrophic cardiomyopathy to the histone deacetylase inhibitor, Trichostatin A, and the mitogen-activated protein kinase kinase 1/2 inhibitor, U0126. We believe this in vivo reporter line will offer a unique approach to the identification of novel chemical or genetic regulators of myocardial hypertrophy and heart failure.