Background: Premature ventricular contractions (PVCs) are common arrhythmias associated with symptoms such as fatigue and, in severe cases, PVC-induced cardiomyopathy. Catheter ablation (CA) is a primary treatment for symptomatic PVCs, particularly when pharmacological therapies fail or are undesired. While improvements in: quality-of-life following ablation are documented, its impact on functional capacity remains underexplored. Objectives: This study evaluated the impact of CA on functional capacity and cardiac stress markers in patients with symptomatic PVCs using cardiopulmonary exercise testing (CPET) and NT-proBNP levels. Methods: A total of 30 patients underwent successful PVC ablation and completed baseline and follow-up CPET evaluations under the Bruce protocol. PVC burden, left ventricular ejection fraction (LVEF), NT-proBNP levels, and CPET parameters, including VO2 max, METS, ventilatory efficiency, and anaerobic threshold (AT), were analyzed pre- and post-ablation. Results: PVC burden significantly decreased post-ablation (23,509.3 ± 10,700.47 to 1759 ± 1659.15, p < 0.001). CPET revealed improved functional capacity, with VO2 max increasing from 24.97 ± 4.16 mL/kg/min to 26.02 ± 4.34 mL/kg/min (p = 0.0096) and METS from 7.16 ± 1.17 to 7.48 ± 1.24 (p = 0.0103). NT-proBNP significantly decreased (240.93 ± 156.54 pg/mL to 138.47 ± 152.91 pg/mL, p = 0.0065). LVEF and ventilatory efficiency metrics (VE/VO2 and VE/VCO2) remained stable. Conclusions: Catheter ablation improves functional capacity, reduces cardiac stress, and minimizes medication dependency in patients with symptomatic PVCs. These findings support the utility of ablation in enhancing aerobic capacity and overall exercise performance.
BACKGROUND High-power short-duration (HPSD) and very-high-power short-duration (vHPSD-90 W/4 s) radiofrequency (RF) technology has reduced the procedure time of pulmonary vein isolation (PVI) using RF without compromising the efficacy of the technique. The current study compares the novel technology of HPSD/vHPSD with cryoablation (CRYO) in terms of efficacy, safety, and procedure time in a cohort of symptomatic patients with paroxysmal atrial fibrillation (pAF). METHODS This is a prospective, non-randomized trial. Patients with pAF received either CRYO or HPSD/vHPSD RF PVI. The primary endpoint of the study was arrhythmia recurrence in a 12 month follow-up period. Secondary endpoints included procedure time, fluoroscopy time, and safety. RESULTS 104 patients were included (45 in HPSD/vHPSD and 59 in CRYO), with comparable characteristics between groups. The follow-up was 12.4 f 0.5 months. There was no significant difference regarding arrhythmia recurrences during the early post-procedural period of the first 3 months (8.9% recurrences in HPSD/vHPSD versus 5.1% in CRYO-p 0.463) and in the mid-term follow-up of 12 months (17.8% recurrences in HPSD/vHPSD versus 10.2% in CRYO-p 0.385). Safety was excellent for both procedures. CRYO was a procedure of significantly shorter duration (64.64 f 8.94 min versus 75.29 f 18.30 min, p = 0.0001) at the expense of longer fluoroscopy time (HPSD/vHPSD 5.34 f 1.83 versus 7.89 f 3.70 min CRYO, p 0.001). CONCLUSIONS HPSD/vHPSD and CRYO in pAF were comparable regarding the arrhythmia recurrence rates in a 12-month follow-up with excellent safety. The hybrid approach of HPSD/vHPSD has accelerated RF-PVI compared to conventional RF, but CRYO remains a procedure of significantly shorter duration at the expense of longer fluoroscopy time. (Hellenic Journal of Cardiology 2025;84:75-80) (c) 2024 Hellenic Society of Cardiology. Publishing services by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Patent ductus arteriosus (PDA) continues to be a significant finding among infants, as well as adults. What is widely considered to be a problem though, in a group of patients with congenital heart disease, it is the only lifeline. We will initially study the anatomical and biochemical mechanisms affecting the PDA. The main focus of this review is on ductal-dependent congenital heart disease and biochemical and pharmacological approaches to maintaining ductus arteriosus patency, as well as surgical and interventional options for maintaining circulation. The present review aims to highlight gaps in the knowledge regarding the multifunctional role of ductus arteriosus endothelium and possibly propose a new approach to pharmacological maintenance of ductus arteriosus patency.
AbstractIntroductionPulsed field ablation (PFA) is a form of nonthermal energy that has been recently introduced for pulmonary vein isolation (PVI). A multi‐electrode pentaspline catheter for delivery of PFA guided by fluoroscopy has become widely available for clinical use.Methods and ResultsIn this study, we aimed to assess whether the addition of electroanatomical mapping (EAM) for confirmation of PVI in the acute phase can increase the efficacy of the procedure in terms of arrhythmia recurrences. A total of 51 patients with atrial fibrillation (AF) scheduled for first time PVI were included in the study. Participants were assigned to receive PVI using fluoroscopy guidance only (Fluoro‐only group: 31 patients) or additional validation with EAM (EAM group: 20 patients). Endpoints included arrhythmia recurrence and procedural characteristics. During a 11.2 ± 1.3 months follow‐up period, arrhythmia recurrences did not statistically differ between groups (16.1% vs. 20%, p .72). Procedure time was longer in the EAM group (86.5 ± 11.4 vs. 78.4 ± 9.3 min, p .008). EAM revealed 5 nonisolated PVs that were re‐ablated using the same catheter. Four patients of the cohort underwent a redo‐procedure during the follow‐up period. In all 4 cases, at least one reconnected PV was identified.ConclusionIn a cohort of patients with AF undergoing first time PVI using a pentaspline PFA catheter, PVI validation with EAM did not lead to significantly different arrhythmia recurrence rates compared to PVI without EAM. In the acute phase, the rate of nonisolated PVs was low.
OBJECTIVE:Implantable loop recorders (ILRs) are increasingly being used for long-term cardiac monitoring in different clinical settings. The aim of this study was to investigate the real-world performance of ILRs-including the time to diagnosis-in unselected patients with different ILR indications. METHODS AND RESULTS:In this multicenter, observational study, 871 patients with an indication of pre-syncope/syncope (61.9%), unexplained palpitations (10.4%), and atrial fibrillation (AF) detection with a history of cryptogenic stroke (CS) (27.7%) underwent ILR implantation. The median follow-up was 28.8 ± 12.9 months. In the presyncope/syncope group, 167 (31%) received a diagnosis established by the device. Kaplan-Meier estimates indicated that 16.9% of patients had a diagnosis at 6 months, and the proportion increased to 22.5% at 1 year. Of 91 patients with palpitations, 20 (22%) received a diagnosis based on the device. The diagnosis was established in 12.2% of patients at 6 months, and the proportion increased to 13.3% at 1 year. Among 241 patients with CS, 47 (19.5%) were diagnosed with AF. The diagnostic yield of the device was 10.4% at 6 months and 12.4% at 1 year. In all cases, oral anticoagulation was initiated. Overall, ILR diagnosis altered the therapeutic strategy in 26.1% of the presyncope/syncope group, 2.2% of the palpitations group, and 3.7% of the CS group in addition to oral anticoagulation initiation. CONCLUSION:In this real-world patient population, ILR determines diagnosis and initiates new therapeutic management for nearly one-fourth of patients. ILR implantation is valuable in the evaluation of patients with unexplained presyncope/syncope, CS, and palpitations.
Key Clinical Message Descending aorta to right atrial (RA) fistula is a rare and distinct clinical entity mimicking patent ductus arteriosus (PDA) and it may lead to rapid development of pulmonary vascular disease. Correct diagnosis and treatment, especially in the presence of other congenital heart defects, is very important. Interventional management is the treatment of choice. Abstract We present a case report of a trisomy 21 infant with atrial and ventricular septal defects and small patent ductus arteriosus (PDA) complicated by the presence of descending aorta to right atrial (RA) fistula with large left to right shunt leading to rapid increase in pulmonary vascular resistance. Transcatheter occlusion of the fistula followed by closure of the PDA with Nit‐Occlud coil systems led to decreased pulmonary pressure and resistance permitting successful surgical repair of the patient's intracardiac defects with good outcome over 3 years of follow‐up. Descending aorta to RA fistula is a rare and distinct clinical entity mimicking PDA and its correct diagnosis and treatment, especially in the presence of other congenital heart defects, is very important as it may lead to rapid development of pulmonary vascular disease.
BACKGROUND:Balloon pulmonary angioplasty (BPA) has provided an effective invasive treatment for inoperable patients with chronic thromboembolic pulmonary hypertension (CTEPH). The hemodynamic improvement achieved by BPA has significantly increased the long-term prognosis of these patients, mostly by reversing the negative remodeling of the right ventricle (RV). MATERIALS AND METHODS:In a cohort of 17 patients with symptomatic CTEPH hemodynamic data were collected before and after the completion of BPA sessions. After the confirmation of statistically significant hemodynamic improvement, we examined the changes in certain prespecified electrocardiographic (ECG) parameters (PR interval duration, QRS duration, QTc interval duration, R wave and S wave amplitude in lead I, R wave and S wave amplitude in precordial leads V1, V5 and V6) before the initiation and one month after the completion of BPA sessions. In addition, ECGs were qualitatively assessed before and after treatment for the presence of ECG abnormalities related to PH, proposed by the guidelines of the European Society of Cardiology (ESC). The term ESC criteria 1-6 was used for their description. RESULTS:Statistically significant correlation (p < 0.05) was found between the reduction in mean pulmonary artery pressure (mPAP) and the decrease of the depth of the S wave in leads I (p 0.0069), V5 (p 0.0003), V6 (p 0.0011) and in the R wave amplitude in leads V5 (p 0.0122) and V6 (p 0.0185). From the ESC criteria, RV strain pattern was the commonest in the initial cohort, with significant improvement after therapies. CONCLUSION:Hemodynamic improvement after BPA therapies is correlated with improved ECG amplitude parameters in leads I, V5 and V6. RV strain pattern is common among untreated patients with significant improvement after therapies.
The Fontan operation, the final palliative step after a series of complex operations in patients with univentricular hearts, has undergone multiple modifications throughout the last decades, with the goal of finding the method which combines the optimal hemodynamic effects of the Fontan circulation with minimal long term side effects. An understanding of the operative evolution and subsequent side effects, as well as the management thereof seems imperative. Since its inception by Francis Fontan the, now obsolete, initial atriopulmonary connection has passed through several milestones into having now reached the era of total cavopulmonary connection. However, recently published results bring to light the new option of biventricular conversion which comes to challenge the management of Fontan patients as we know it. Currently, there is no consensus as to whether to continue with palliation in this challenging group of patients or proceed with heart transplantation. In this collective review, we provide a historic overview of the Fontan evolution as well as future insights, discussing the perspectives of options for patients with failing Fontan, including the latest addition of biventricular correction.
Enhanced ventricular arrhythmogenesis is commonly experienced by patients in the end-stage of heart failure spectrum. A high burden of ventricular arrhythmias can affect the ventricular systolic function, lead to unexpected hospitalizations and further deteriorate the prognosis. Management of ventricular arrhythmias in this population is challenging. Implantable cardioverter-defibrillators are protective for the immediate termination of life-threatening arrhythmias but they have no impact in reducing the arrhythmic burden. Combination treatment with invasive (catheter ablation, mechanical hemodynamic support, sympathetic denervation) and noninvasive (antiarrhythmic drugs, medical therapy for heart failure, programming of implantable devices) therapies is commonly required. The aim of this review is to present the available therapeutic options, with main focus on recently published data for catheter ablation and provide a stepwise treatment approach.
Although mitral valve prolapse (MVP) is usually considered a benign clinical condition, it has been linked with ventricular arrhythmias and sudden cardiac death in patients with a certain “arrhythmic” phenotype, raising awareness and mandating a specific risk stratification protocol. Mitral annular disjunction (MAD) is considered a “red flag” in malignant MVP syndrome along with bileaflet myxomatous prolapse, female gender, negative or biphasic T waves in the inferior leads, fibrosis in the papillary muscles or inferobasal wall detected by cardiac magnetic resonance imaging and complex arrhythmias of right bundle branch morphology. MAD seems to play a critical role in the chain of morphofunctional abnormalities which lead to increased mechanical stretch and subsequent fibrosis mainly in the papillary muscles, forming the vulnerable anatomic substrate prone to arrhythmogenesis, and associated with long-term severe ventricular arrhythmias. Arrhythmogenesis in MVP/MAD patients is not fully understood but a combination between a substrate and a trigger has been established with premature ventricular contraction triggered ventricular fibrillation being the main mechanism of sudden cardiac death (SCD). Certain characteristics mostly recognized by non-invasive imaging modalities serve as risk factors and can be used to diagnose and identify high risk patients with MAD, while treatment options include catheter ablation, device therapy and surgical intervention. This review focuses on the clinical presentation, the arrhythmogenic substrate, and the incidence of ventricular arrhythmias and SCD in MAD population. The current risk stratification tools in MAD arrhythmogenic entity are discussed.