We present Sunyaev-Zel’dovich (SZ) effect measurements from wide-field images toward the galaxy cluster RX J1347.5−1145 obtained from the Caltech Submillimeter Observatory with the Multiwavelength Submillimeter Inductance Camera at 147, 213, 281, and 337 GHz and with Bolocam at 140 GHz. As part of our analysis, we have used higher frequency data from Herschel–SPIRE and previously published lower frequency radio data to subtract the signal from the brightest dusty star-forming galaxies behind RX J1347.5−1145 and from the AGN in RX J1347.5−1145’s BCG. Using these five-band SZ effect images, combined with X-ray spectroscopic measurements of the temperature of the intra-cluster medium (ICM) from Chandra, we constrain the ICM optical depth to be τ e = 7.33 − 0.97 + 0.96 × 10 − 3 ?> and the ICM line of sight peculiar velocity to be v pec = − 1040 − 840 + 870 ?> km s−1. The errors for both quantities are limited by measurement noise rather than calibration uncertainties or astrophysical contamination, and significant improvements are possible with deeper observations. Our best-fit velocity is in good agreement with one previously published SZ effect analysis and in mild tension with the other, although some or all of that tension may be because that measurement samples a much smaller cluster volume. Furthermore, our best-fit optical depth implies a gas mass slightly larger than the Chandra-derived value, implying the cluster is elongated along the line of sight.
The Multiwavelength Sub/millimeter Inductance Camera (MUSIC) is a four-band photometric imaging camera operating from the Caltech Submillimeter Observatory (CSO). MUSIC is designed to utilize 2304 microwave kinetic inductance detectors (MKIDs), with 576 MKIDs for each observing band centered on 150, 230, 290, and 350 GHz. MUSIC's field of view (FOV) is 14' square, and the point-spread functions (PSFs) in the four observing bands have 45 '', 31 '', 25 '', and 22 '' full-widths at half maximum (FWHM). The camera was installed in April 2012 with 25% of its nominal detector count in each band, and has subsequently completed three short sets of engineering observations and one longer duration set of early science observations. Recent results from on-sky characterization of the instrument during these observing runs are presented, including achieved map-based sensitivities from deep integrations, along with results from lab-based measurements made during the same period. In addition, recent upgrades to MUSIC, which are expected to significantly improve the sensitivity of the camera, are described.
We present the status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera, a new instrument for the Caltech Submillimeter Observatory. MUSIC is designed to have a 14', diffraction-limited field-of-view instrumented with 2304 detectors in 576 spatial pixels and four spectral bands at 0.87, 1.04, 1.33, and 1.98 mm. MUSIC will be used to study dusty star-forming galaxies, galaxy clusters via the Sunyaev-Zeldovich effect, and star formation in our own and nearby galaxies. MUSIC uses broadband superconducting phased-array slot-dipole antennas to form beams, lumped-element on-chip bandpass filters to define spectral bands, and microwave kinetic inductance detectors to senseincoming light. The focal plane is fabricated in 8 tiles consisting of 72 spatial pixels each. It is coupled to the telescope via an ambient temperature ellipsoidal mirror and a cold reimaging lens. A cold Lyot stop sits at the image of the primary mirror formed by the ellipsoidal mirror. Dielectric and metal mesh filters are used to block thermal infrared and out-of-band radiation. The instrument uses a pulse tube cooler and 3He/3He/4He closed-cycle cooler to cool the focal plane to below 250 mK. A multilayer shield attenuates Earth's magnetic field. Each focal plane tile is read out by a single pair of coaxes and a HEMT amplifier. The readout system consists of 16 copies of custom-designed ADC/DAC and IF boards coupled to the CASPER ROACH platform. We focus on recent updates on the instrument design and results from the commissioning of the full camera in 2012.
This paper will present the design, implementation, performance analysis of an open source readout system for arrays of microwave kinetic inductance detectors (MKID) for mm/submm astronomy. The readout system will perform frequency domain multiplexed real-time complex microwave transmission measurements in order to monitor the instantaneous resonance frequency and dissipation of superconducting microresonators. Each readout unit will be able to cover up to 550 MHz bandwidth and readout 256 complex frequency channels simultaneously. The digital electronics include the customized DAC, ADC, IF system and the FPGA based signal processing hardware developed by CASPER group.(1-7) The entire system is open sourced, and can be customized to meet challenging requirement in many applications: e.g. MKID, MSQUID etc.
Detectors employing superconducting microwave kinetic inductance detectors (MKIDs) can be read out by measuring changes in either the resonator frequency or dissipation. We will discuss the pros and cons of both methods, in particular, the readout method strategies being explored for the Multiwavelength Sub/millimeter Inductance Camera (MUSIC) to be commissioned at the CSO in 2010. As predicted theoretically and observed experimentally, the frequency responsivity is larger than the dissipation responsivity, by a factor of 2-4 under typical conditions. In the absence of any other noise contributions, it should be easier to overcome amplifier noise by simply using frequency readout. The resonators, however, exhibit excess frequency noise which has been ascribed to a surface distribution of two-level fluctuators sensitive to specific device geometries and fabrication techniques. Impressive dark noise performance has been achieved using modified resonator geometries employing interdigitated capacitors (IDCs). To date, our noise measurement and modeling efforts have assumed an onresonance readout, with the carrier power set well below the nonlinear regime. Several experimental indicators suggested to us that the optimal readout technique may in fact require a higher readout power, with the carrier tuned somewhat off resonance, and that a careful systematic study of the optimal readout conditions was needed. We will present the results of such a study, and discuss the optimum readout conditions as well as the performance that can be achieved relative to BLIP.
We will present the design and implementation, along with calculations and some measurements of the performance, of the room-temperature and cryogenic optics for MUSIC, a new (sub)millimeter camera we are developing for the Caltech Submm Observatory (CSO). The design consists of two focusing elements in addition to the CSO primary and secondary mirrors: a warm off-axis elliptical mirror and a cryogenic (4K) lens. These optics will provide a 14 arcmin field of view that is diffraction limited in all four of the MUSIC observing bands (2.00, 1.33, 1.02, and 0.86 mm). A cold (4K) Lyot stop will be used to define the primary mirror illumination, which will be maximized while keeping spillover at the sub 1% level. The MUSIC focal plane will be populated with broadband phased antenna arrays that efficiently couple to factor of (see manuscript) 3 in bandwidth,1, 2 and each pixel on the focal plane will be read out via a set of four lumped element filters that define the MUSIC observing bands (i.e., each pixel on the focal plane simultaneously observes in all four bands). Finally, a series of dielectric and metal-mesh low pass filters have been implemented to reduce the optical power load on the MUSIC cryogenic stages to a quasi-negligible level while maintaining good transmission in-band.
MUSIC (Multicolor Submillimeter kinetic Inductance Camera) is a new facility instrument for the Caltech Submillimeter Observatory (Mauna Kea, Hawaii) developed as a collaborative effect of Caltech, JPL, the University of Colorado at Boulder and UC Santa Barbara, and is due for initial commissioning in early 2011. MUSIC utilizes a new class of superconducting photon detectors known as microwave kinetic inductance detectors (MKIDs), an emergent technology that offers considerable advantages over current types of detectors for submillimeter and millimeter direct detection. MUSIC will operate a focal plane of 576 spatial pixels, where each pixel is a slot line antenna coupled to multiple detectors through on-chip, lumped-element filters, allowing simultaneously imaging in four bands at 0.86, 1.02, 1.33 and 2.00 mm. The MUSIC instrument is designed for closed-cycle operation, combining a pulse tube cooler with a two-stage Helium-3 adsorption refrigerator, providing a focal plane temperature of 0.25 K with intermediate temperature stages at approximately 50, 4 and 0.4 K for buffering heat loads and heat sinking of optical filters. Detector readout is achieved using semi-rigid coaxial cables from room temperature to the focal plane, with cryogenic HEMT amplifiers operating at 4 K. Several hundred detectors may be multiplexed in frequency space through one signal line and amplifier. This paper discusses the design of the instrument cryogenic hardware, including a number of features unique to the implementation of superconducting detectors. Predicted performance data for the instrument system will also be presented and discussed.
MUSIC (the Multiwavelength Submillimeter kinetic Inductance Camera) is an instrument being developed for the Caltech Submillimeter Observatory by Caltech, JPL, the University of Colorado, and UCSB. MUSIC uses microwave kinetic inductance detectors (MKIDs) - superconducting micro-resonators - as photon detectors. The readout is almost entirely at room temperature and is highly multiplexed. MUSIC will have 576 spatial pixels in four bands at 850, 1100, 1300 and 2000 microns. MUSIC is scheduled for deployment at the CSO in the winter of 2010/2011. We present an overview of the camera design and readout and describe the current status of the instrument and some results from the highly successful May/June 2010 observing run at the CSO with the prototype camera, which verified the performance of the complete system (optics, antennas/filters, resonators, and readout) and produced the first simultaneous 3-color observations with any MKID camera.
We present the results of the latest multicolor Microwave Kinetic Inductance Detector (MKID) focal plane arrays in the submillimeter. The new detectors on the arrays are superconducting resonators which combine a coplanar waveguide section with an interdigitated capacitor, or IDC. To avoid out-of-band pickup by the capacitor, a stepped-impedance filter is used to prevent radiation from reaching the absorptive aluminum section of the resonator. These arrays are tested in the preliminary demonstration instrument, DemoCam, a precursor to the Multicolor Submillimeter Inductance Camera, MUSIC. We present laboratory results of the responsivity to light both in the laboratory and at the Caltech Submillimeter Observatory. We assess the performance of the detectors in filtering out-of-band radiation, and find the level of excess load and its effect on detector performance. We also look at the array design characteristics, and the implications for the optimization of sensitivities expected by MUSIC.
Microwave Kinetic Inductance Detectors (MKIDs) are superconducting microresonators useful as detectors for sub/millimeter and far-infrared cameras, as well as instruments in optical and x-ray wavelengths. A probe sine wave at the resonance frequency can detect a change in frequency and microwave loss due to submillimeter optical load as a phase or amplitude change. These detectors may be coupled to light through on-chip, phased-array antennas. A single antenna may feed several detectors with different bandpasses defined by on-chip lumped-element filters. The resonators are easily frequency multiplexed by tuning the resonance frequencies, so hundreds of detectors can be read out while coupled to a single feedline. The deployment and operation of ground-based, background-limited detectors in close-packed arrays present significant challenges in both readout strategy and array design. The initial designs consisted of simple coplanar waveguide microwave resonators with aluminum absorptive sections. The first change has been to substitute the capacitive portion of the resonator with a large interdigitated capacitor (IDC) to reduce its noise contribution. While their low-noise characteristics have been demonstrated, these detectors had not yet been tested on array-scale devices. We present results from arrays of detectors designed for sub/millimeter imaging, tested for their optical response characteristics. In particular, we address challenges of microwave inter-resonator coupling, out-of-band resonator optical sensitivity, and noise reduction in the latest device designs. We show the results of stepped-impedance filters in preventing direct pickup of wide-band radiation, and new frequency spacing to limit crosstalk between resonators. We show direct comparison between olderdesign coplanar waveguide resonators and new IDC resonators under optical load, demonstrating the noise reduction and comparable responsivity. In addition, we show results of the probe signal readout power that maximizes signal-to-noise.
The opacity due to water vapor in the Earth's atmosphere obscures portions of the sub-THz spectrum (mm/sub-mm wavelengths) to ground based astronomical observation. For maximum sensitivity, instruments operating at these wavelengths must be designed to have spectral responses that match the available windows in the atmospheric transmission that occur in between the strong water absorption lines. Traditionally, the spectral response of mm/sub-mm instruments has been set using optical, metal-mesh bandpass filters [1]. An alternative method for defining the passbands, available when using superconducting detectors coupled with planar antennas, is to use on-chip, superconducting filters [2]. This paper presents the design and testing of superconducting, lumped element, on-chip bandpass filters (BPFs), placed inline with the microstrip connecting the antenna and the detector, covering the frequency range from 209-416 GHz. Four filters were designed with pass bands 209-274 GHz, 265-315 GHz, 335-361 GHz and 397-416 GHz corresponding to the atmospheric transmission windows. Fourier transform spectroscopy was used to verify that the spectral response of the BPFs is well predicted by the computer simulations. Two-color operation of the pixels was demonstrated by connecting two detectors to a single broadband antenna through two BPFs. Scalability of the design to multiple (four) colors is discussed.
We are using Microwave Kinetic Inductance Detectors in a sub/millimeter camera for the Caltech Submillimeter Observatory. These detectors are microwave resonators that rely on submillimeter and millimeter-wave photons to break Cooper pairs, changing the surface impedance. This changes the resonator frequency and quality factor, Q, and is measured by probe signals sent through a feedline coupled to the detectors. The camera will be divided into 16 independent readout tiles, each of which will fit 144 resonators at different frequencies into 360 MHz of bandwidth. We discuss the effect of readout power and single pixel frequency responsivity on the NEP of the detectors. Finally, we consider the mapping speeds of a full tile as a function of Q, which is controlled through the detector volume. A lower Q at fixed optical power implies greater responsivity, while a higher Q decreases the collision probability - the likelihood that any two resonators will have close enough resonant frequencies for crosstalk to be unacceptably high. We find the optimal design based on these constraints, and the corresponding mapping speeds expected at the telescope.
Developing kilopixel focal planes for incoherent submm- and mm-wave detectors remains challenging due to either the large hardware overhead or the complexity of multiplexing standard detectors. Microwave kinetic inductance detectors (MKIDs) provide a efficient means to produce fully lithographic background-limited kilopixel focal planes. We are constructing an MKID-based camera for the Caltech Submillimeter Observatory with 576 spatial pixels each simultaneously sensitive in 4 bands at 230, 300, 350, and 400 GHz. The novelty of MKIDs has required us to develop new techniques for detector characterization. We have measured quasiparticle lifetimes and resonator Qs for detector bath temperatures between 200 mK and 400 mK. Equivalent lifetime measurements were made by coupling energy into the resonators either optically or by driving the third harmonic of the resonator. To determine optical loading, we use both lifetime and internal Q measurements, which range between 15,000 and 30,000 for our resonators. Spectral bandpass measurements confirm the placement of the 230 and 350 GHz bands. Additionally, beam maps measurements conform to expectations. The same device design has been characterized on both sapphire and silicon substrates, and for different detector geometries. We also report on the incorporation of new shielding to reduce detector sensitivity to local magnetic fields.
We have developed a new technique for accurate measurement of the loss of superconducting microstrips at mm-wave frequencies. In this technique, we optically couple power to slot antenna, which is connected to one port of a hybrid coupler. One of the output ports of the hybrid delivers power to a series of mm-wave microstrip resonators which are capacitively coupled to a feedline followed by an MKID (microwave kinetic inductance detector) that measures the transmitted power. Two other MKIDs are connected to the remaining ports of the hybrid to measure the total incident optical power and the power reflected from the mm-wave resonators, allowing vertical bar S-21 vertical bar(2) and vertical bar S-11 vertical bar(2) to be accurately determined and resonance frequency f(r) and quality factor Q to be retrieved. We have fabricated such a Nb/SiO2/Nb microstrip loss test device which contains several mm- wave resonators with f(r) similar to 100 GHz and measured it at 30 mK. All the resonators have shown internal quality factor Q(i) similar to 500 - 2000, suggesting a loss tangent of similar to 5 x 10(-4) 2 x 10(-3) for the SiO2 in use. For comparison, we have also fabricated a 5 GHz microstrip resonator on the same chip and measured it with a network analyzer. The loss tangent at 5 GHz derived from fitting the f(0) and Q data to the two-level system (TLS) model is 6 x 10(-4), about the same as from the mm-wave measurement. This suggests that the loss at both microwave and mm-wave frequencies is probably dominated by the TLS in SiO2. Our results are of direct interest to mm/submm direct detection applications which use microstrip transmission lines (such as antenna-coupled MKIDs and transition-edge sensors), and other applications (such as on-chip filters). Our measurement technique is applicable up to approximately 1 THz and can be used to investigate a range of dielectrics.
The MKID Camera project is a collaborative effort of Caltech, JPL, the University of Colorado, and UC Santa Barbara to develop a large‐format, multi‐color millimeter and submillimeter‐wavelength camera for astronomy using microwave kinetic inductance detectors (MKIDs). These are superconducting, micro‐resonators fabricated from thin aluminum and niobium films. We couple the MKIDs to multi‐slot antennas and measure the change in surface impedance produced by photon‐induced breaking of Cooper pairs. The readout is almost entirely at room temperature and can be highly multiplexed; in principle hundreds or even thousands of resonators could be read out on a single feedline.The camera will have 576 spatial pixels that image simultaneously in four bands at 750, 850, 1100 and 1300 microns. It is scheduled for deployment at the Caltech Submillimeter Observatory in the summer of 2010. We present an overview of the camera design and readout and describe the current status of testing and fabrication.
We present measurements of the low-temperature excess frequency noise of four niobium superconducting coplanar waveguide microresonators, with center strip widths sr ranging from 3to20μm. For a fixed internal power, we find that the frequency noise decreases rapidly with increasing center strip width, scaling as 1∕sr1.6. We show that this geometrical scaling is readily explained by a simple semiempirical model which assumes a surface distribution of independent two-level system fluctuators. These results allow the resonator geometry to be optimized for minimum noise.
The responsivity of microwave kinetic inductance detector (MKID) is related to the derivative of the complex conductivity σ with respect to the quasiparticle density n qp. For thermal quasiparticles, this derivative \(d\sigma/dn_{\rm{qp}}\) can be evaluated from σ(T) and n qp(T) given by the Marttis-Bardeen theory (Phys. Rev. 14:412, [1958]). For excess quasiparticles due to external pair breaking, d σ/dn qp can be evaluated by introducing an effective chemical potential μ * into the Marttis-Bardeens theory, as did by Owen and Scalapino (Phys. Rev. Lett. 28:1559, [1972]).